{"title":"Effect of Abutments Design on Wear of Locator Attachments in Effect of Abutments Design on Wear of Locator Attachments in Implant Retained Mandibular Overdenture","authors":"M. Fayed, M. Abdelaziz, Hossam I. Nassar","doi":"10.54623/fdj.80110","DOIUrl":null,"url":null,"abstract":"Purpose: The aim of this study is to compare the effect of abutments design on wear behavior of Locator attachments in implant-retained mandibular overdenture. Materials and Methods: Two epoxy models representing an edentulous mandible were used, two implants were placed in each model. Twenty-four locator attachments were used (twelve in each study group). Cycles of Insertion and removal were performed using a universal testing machine resembling 3 years of clinical use, then each abutment was scanned by scanning electron microscope (SEM) before and after insertion and removal cycles. Data were compared qualitatively using a specialized computer software Results: There was a statistically significant difference in wear between the two studied locator groups P=0000*. Locator F-TX showed 29±1.704 % of surface change. PEEKLOC. Locator showed 21±2.090 %of surface change. Conclusions: PEEKLoc. abutment design showed more wear resistance than the recently introduced Locator F-TX.","PeriodicalId":100562,"journal":{"name":"Future Dental Journal","volume":"7 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2022-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Future Dental Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.54623/fdj.80110","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: The aim of this study is to compare the effect of abutments design on wear behavior of Locator attachments in implant-retained mandibular overdenture. Materials and Methods: Two epoxy models representing an edentulous mandible were used, two implants were placed in each model. Twenty-four locator attachments were used (twelve in each study group). Cycles of Insertion and removal were performed using a universal testing machine resembling 3 years of clinical use, then each abutment was scanned by scanning electron microscope (SEM) before and after insertion and removal cycles. Data were compared qualitatively using a specialized computer software Results: There was a statistically significant difference in wear between the two studied locator groups P=0000*. Locator F-TX showed 29±1.704 % of surface change. PEEKLOC. Locator showed 21±2.090 %of surface change. Conclusions: PEEKLoc. abutment design showed more wear resistance than the recently introduced Locator F-TX.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
基台设计对定位器附着体磨损的影响基台设计对种植下颌覆盖义齿定位器附着体磨损的影响
目的:比较不同基台设计对下颌种植覆盖义齿Locator附着体磨损行为的影响。材料与方法:采用两个环氧树脂模型,每个模型放置两个种植体。使用了24个定位器附件(每个研究组12个)。采用类似临床使用3年的通用试验机进行插入和移除周期,然后在插入和移除周期前后对每个基台进行扫描电镜(SEM)扫描。使用专门的计算机软件对数据进行定性比较。结果:所研究的两组定位器之间的磨损差异具有统计学意义P=0000*。定位仪F-TX显示29±1.704%的表面变化。PEEKLOC。定位仪显示表面变化21±2.090%。结论:PEEKLoc。基台设计比最近推出的Locator F-TX更具耐磨性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Measuring Accuracy of Dolphin Imaging Software in predicting upper jaw soft tissue profile changes in Class II Adult Patients treated with Extraction versus Non-Extraction Success of Early Childhood Caries After Treatment with Silver Diamine Fluoride Compared to conventional Glass Ionomer Restoration. A Systematic Review Comparison of Alignment Duration Between 0.018” And 0.022” Slot Brackets in Non-Extraction Orthodontic Adult Patients: A Randomized Clinical Study The Efficiency of Passive Ultrasonic Activated Irrigation on the Retrievability of Guttaflow Bioseal : In Vitro Study Radiographic Analysis of Umbrella Technique Combined with Sticky Bone in Horizontal Ridge Augmentation
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1