Analyse informatisée du rythme cardiaque fœtal au cours de la grossesse et de l'accouchement

G Boog (Professeur de gynécologie-obstétrique)
{"title":"Analyse informatisée du rythme cardiaque fœtal au cours de la grossesse et de l'accouchement","authors":"G Boog (Professeur de gynécologie-obstétrique)","doi":"10.1016/j.emcgo.2003.12.001","DOIUrl":null,"url":null,"abstract":"<div><p>Three computer-based methods for analyzing fetal heart rhythm (FHR) have been developed recently. They use the fetal electrocardiograph (STAN software), short-term variability (STV) measurement based on comparisons of intervals between beats (Oxford 8002 software), and frequential analysis by conversion of the time signal to a frequency spectrum (according to the Fourier principle), respectively. As compared to conventional visual FHR analysis, a T/QRS ratio increase and presence of biphasic ST-segment waves recorded by STAN, a STV value lower than 6 milliseconds at full term with Oxford, and a decrease in low frequencies with an increase in very low frequencies ensure more reliable detection of fetal asphyxia during labor.</p></div>","PeriodicalId":100424,"journal":{"name":"EMC - Gynécologie-Obstétrique","volume":"1 1","pages":"Pages 7-21"},"PeriodicalIF":0.0000,"publicationDate":"2004-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/j.emcgo.2003.12.001","citationCount":"6","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"EMC - Gynécologie-Obstétrique","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1762614503000064","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6

Abstract

Three computer-based methods for analyzing fetal heart rhythm (FHR) have been developed recently. They use the fetal electrocardiograph (STAN software), short-term variability (STV) measurement based on comparisons of intervals between beats (Oxford 8002 software), and frequential analysis by conversion of the time signal to a frequency spectrum (according to the Fourier principle), respectively. As compared to conventional visual FHR analysis, a T/QRS ratio increase and presence of biphasic ST-segment waves recorded by STAN, a STV value lower than 6 milliseconds at full term with Oxford, and a decrease in low frequencies with an increase in very low frequencies ensure more reliable detection of fetal asphyxia during labor.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
怀孕和分娩期间胎儿心率的计算机分析
最近发展了三种基于计算机的胎儿心律(FHR)分析方法。他们分别使用胎儿心电图仪(STAN软件)、基于心跳间隔比较的短期变异性(STV)测量(Oxford 8002软件)和通过将时间信号转换为频谱(根据傅立叶原理)进行频率分析。与传统的视觉FHR分析相比,通过STAN记录的T/QRS比增加和双相st段波的存在,在足月时使用Oxford记录的STV值低于6毫秒,以及低频的减少和极低频的增加确保了更可靠的分娩过程中胎儿窒息的检测。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Cancer du sein et radiothérapie peropératoire par électrons (IOERT) Malformations utérines et infertilité Diagnostic pré-implantatoire Symptômes douloureux de l'endométriose Editorial Board
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1