{"title":"The influence of layer height on the tensile strength of specimens printed in the FDM technology","authors":"Ł. Miazio","doi":"10.31648/ts.6297","DOIUrl":null,"url":null,"abstract":"This article analyzes the influence of layer height on the tensile strength of PLA specimens printed in the Fused Deposition Modeling (FDM) technology. The maximum breaking force of specimens with 30% and 100% infill density was determined at layer height of 0.05 mm, 0.1 mm, 0.2 mm and 0.3 mm. In the case of 30% infill, the highest value of the force was obtained for a layer with a height of 0.05 mm (which corresponds to 22.7 MPa), and for a 100% infill for a layer of 0.2 (which corresponds to 40 MPa). Over this layer height of 0.2 mm is the most polyoptimal due to the time prints and strength (which corresponds to 19.7 MPa).","PeriodicalId":41669,"journal":{"name":"Archives for Technical Sciences","volume":null,"pages":null},"PeriodicalIF":0.2000,"publicationDate":"2021-08-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Archives for Technical Sciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.31648/ts.6297","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, GEOLOGICAL","Score":null,"Total":0}
引用次数: 0

Abstract

This article analyzes the influence of layer height on the tensile strength of PLA specimens printed in the Fused Deposition Modeling (FDM) technology. The maximum breaking force of specimens with 30% and 100% infill density was determined at layer height of 0.05 mm, 0.1 mm, 0.2 mm and 0.3 mm. In the case of 30% infill, the highest value of the force was obtained for a layer with a height of 0.05 mm (which corresponds to 22.7 MPa), and for a 100% infill for a layer of 0.2 (which corresponds to 40 MPa). Over this layer height of 0.2 mm is the most polyoptimal due to the time prints and strength (which corresponds to 19.7 MPa).
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
层高对FDM打印试样抗拉强度的影响
本文分析了层高对熔融沉积成型(FDM)技术打印PLA样品抗拉强度的影响。在层高分别为0.05 mm、0.1 mm、0.2 mm和0.3 mm时,测定了30%和100%填充密度试样的最大断裂力。当填充量为30%时,层高为0.05 mm时受力最大(对应22.7 MPa),当填充量为100%时,层高为0.2 mm时受力最大(对应40 MPa)。由于打印时间和强度(对应于19.7 MPa),该层高度为0.2 mm是最优的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Archives for Technical Sciences
Archives for Technical Sciences ENGINEERING, GEOLOGICAL-
自引率
0.00%
发文量
10
期刊最新文献
EFFECTS OF LANDFILL LEACHES ON GROUND AND SURFACE WATERS: A CASE STUDY OF A WILD LANDFILL IN EASTERN BOSNIA AND HERZEGOVINA ARCHITECTURAL DESIGNING THE NURSING HOMES IN TEHRAN CITY (AS A SAMPLE) ANALYSIS OF OCCUPATIONAL INJURIES IN AN IRON ORE MINE IN BOSNIA AND HERZEGOVINA IN THE PERIOD FROM 2002 TO 2021 LIQUEFACTION-INDUCED DAMAGE IN THE CITIES OF ISKENDERUN AND GOLBASI AFTER THE 2023 TURKEY EARTHQUAKE IDENTIFICATION AND ANALYSIS OF RISKS IN CIVIL ENGINEERING PROJECTS
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1