{"title":"Research on Analysis Method of Current Loop Fault in High Voltage Electric Energy Metering Device","authors":"Chaonan Liu, Hongzhen Fan, Yuchen Tian, Jinliang Wang, Hao Zhang, Weiwei Yang","doi":"10.1109/ATEEE54283.2021.00017","DOIUrl":null,"url":null,"abstract":"A large number of clean energy sources, such as distributed photovoltaics and wind power are connected to the grid, which further increases the number of electric energy metering devices. Three-phase three-wire electric energy meters connected by PT and CT are widely used in low-current grounding systems of 35kV and below, and due to the complicated wiring, there are a large number of wrong wiring on site, resulting in inaccurate measurement and loss of state-owned assets. Therefore, higher requirements are put forward for the ability of on-site staff to check and analyze the wrong wiring of the electric energy meter. Aiming at the situation of incorrect measurement caused by the current loop failure, this paper proposes a simple analysis method for the secondary outlet and current of the electric energy meter of the sum and difference current, which greatly improves the accuracy of the analysis and shortens the analysis time. The effectiveness of this method is verified through the analysis of numerical examples.","PeriodicalId":62545,"journal":{"name":"电工电能新技术","volume":"26 1","pages":"41-45"},"PeriodicalIF":0.0000,"publicationDate":"2021-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"电工电能新技术","FirstCategoryId":"1087","ListUrlMain":"https://doi.org/10.1109/ATEEE54283.2021.00017","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

A large number of clean energy sources, such as distributed photovoltaics and wind power are connected to the grid, which further increases the number of electric energy metering devices. Three-phase three-wire electric energy meters connected by PT and CT are widely used in low-current grounding systems of 35kV and below, and due to the complicated wiring, there are a large number of wrong wiring on site, resulting in inaccurate measurement and loss of state-owned assets. Therefore, higher requirements are put forward for the ability of on-site staff to check and analyze the wrong wiring of the electric energy meter. Aiming at the situation of incorrect measurement caused by the current loop failure, this paper proposes a simple analysis method for the secondary outlet and current of the electric energy meter of the sum and difference current, which greatly improves the accuracy of the analysis and shortens the analysis time. The effectiveness of this method is verified through the analysis of numerical examples.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
高压电能计量装置电流回路故障分析方法研究
分布式光伏、风电等大量清洁能源并网,进一步增加了电能计量装置的数量。采用PT、CT连接的三相三线制电能表广泛应用于35kV及以下的小电流接地系统中,由于接线复杂,现场存在大量接线错误,造成计量不准确,造成国有资产损失。因此对现场工作人员检查和分析电能表接线错误的能力提出了更高的要求。针对电流回路失效导致测量不正确的情况,本文提出了一种简单的电能表二次出口及和差电流的分析方法,大大提高了分析的准确性,缩短了分析时间。通过数值算例分析,验证了该方法的有效性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
3166
期刊介绍:
期刊最新文献
Medical product sales forecasting at pharmaceutical distribution company (Case study: PT. Lenko Surya Perkasa Branch Office Sidoarjo) Generator capacity predictor system modeling using decision tree regressor at PT Saka Indonesia Pangkah Limited Performance analysis method through process variable modeling to maintain top product quality on fuel gas scrubber performance: A case study of fuel gas scrubber 141-V-01 Synthesis and characterization of folic acid-functionalized, doxorubicin-loaded magnetic nanoparticles as drug delivery system for cancer Hydrolysis optimization for producing acetone-butanol-ethanol from waste palm Empty Bunches after pretreatment process with alkali peroxide
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1