Computer Simulation and Analytical Solutions in the Study of the Transient Radiation-Induced Conductivity in Polymers

July 16 Pub Date : 1984-07-16 DOI:10.1002/PSSA.2210840141
G. S. Mingaleev, A. Tyutnev, V. Arkhipov, A. Rudenko, A. V. Vannikov, V. Saenko
{"title":"Computer Simulation and Analytical Solutions in the Study of the Transient Radiation-Induced Conductivity in Polymers","authors":"G. S. Mingaleev, A. Tyutnev, V. Arkhipov, A. Rudenko, A. V. Vannikov, V. Saenko","doi":"10.1002/PSSA.2210840141","DOIUrl":null,"url":null,"abstract":"Various aspects of the kinetics of the radiation-induced conductivity in polymers, i.e. build-up and decay curves, non-linear dose rate effects, approach to the steady state are investigated by means of approximate analytical solutions as well as computer simulation for the case of exponential trap distribution (computer calculations are performed specifically for the case of dispersion parameter α = 0.5). The widest possible range of irradiation conditions is covered (pulse length 1 ns, 100 μs, 10 ps, 0.1 ms including the steady state; dose per pulse from zero to 105 Gy). The problem of the best choice of normalization parameters is also briefly discussed. \n \n \n \nVerschiedene Aspekte der Kinetik der strahlungsinduzierten Leitfahigkeit in Polymeren, d. h. die An-und Abklingkurven, nichtlineare Dosisrateneffekte, das Erreichen des stationaren Zustands, werden sowohl mittels analytischer Naherungslosungen als auch mit Computersimulation fur den Fall einer exponentiellen Haftstellenverteilung untersucht (die Computerberechnungen speziell fur einen Dispersionsparameter α = 0,5). Der weitestmogliche Bereich von Strahlungsbedingungen wird uberdeckt (Impulslange 1 ns, 100 ns, 10 ps, 0,1 ms einschlieslich des stationaren Zustands; Dosis pro Impuls reicht von Null bis 105 Gy). Das Problem der besten Wahl der Normierungs-parameter wird kurz diskutiert.","PeriodicalId":17793,"journal":{"name":"July 16","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"1984-07-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"July 16","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1002/PSSA.2210840141","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

Abstract

Various aspects of the kinetics of the radiation-induced conductivity in polymers, i.e. build-up and decay curves, non-linear dose rate effects, approach to the steady state are investigated by means of approximate analytical solutions as well as computer simulation for the case of exponential trap distribution (computer calculations are performed specifically for the case of dispersion parameter α = 0.5). The widest possible range of irradiation conditions is covered (pulse length 1 ns, 100 μs, 10 ps, 0.1 ms including the steady state; dose per pulse from zero to 105 Gy). The problem of the best choice of normalization parameters is also briefly discussed. Verschiedene Aspekte der Kinetik der strahlungsinduzierten Leitfahigkeit in Polymeren, d. h. die An-und Abklingkurven, nichtlineare Dosisrateneffekte, das Erreichen des stationaren Zustands, werden sowohl mittels analytischer Naherungslosungen als auch mit Computersimulation fur den Fall einer exponentiellen Haftstellenverteilung untersucht (die Computerberechnungen speziell fur einen Dispersionsparameter α = 0,5). Der weitestmogliche Bereich von Strahlungsbedingungen wird uberdeckt (Impulslange 1 ns, 100 ns, 10 ps, 0,1 ms einschlieslich des stationaren Zustands; Dosis pro Impuls reicht von Null bis 105 Gy). Das Problem der besten Wahl der Normierungs-parameter wird kurz diskutiert.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
聚合物瞬态辐射导电性研究的计算机模拟与解析解
辐射诱导聚合物电导率动力学的各个方面,即建立和衰减曲线,非线性剂量率效应,接近稳态的方法,通过近似解析解以及指数陷阱分布情况下的计算机模拟进行了研究(计算机计算专门用于色散参数α = 0.5的情况)。最宽的辐照条件范围(脉冲长度1 ns, 100 μs, 10 ps, 0.1 ms,包括稳态;每脉冲剂量从零到105戈瑞)。并简要讨论了归一化参数的最佳选择问题。Verschiedene aspekene der strahlungsindustrieten Leitfahigkeit in Polymeren, d. h. die an - and Abklingkurven, nichtlineare Dosisrateneffekte, das Erreichen des stationaren Zustands, werden sohlmitels analytischer Naherungslosungen也auch mit Computersimulation for den Fall einer exponentiellen hafstellenvereilung unsuht (die Computerberechnungen speziell for inen色散参数α = 0,5)。1、100秒、10秒、0.1秒的脉冲动力系统;Dosis pro impulse reicht von Null (105gy)。[2]最佳Wahl der normierungs问题-参数库尔兹离散。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Magnetic Properties of the FexCo 1-x Cr2S4(0 Evaluation of Chromium Concentration in Semi-Insulating (*aAs:Cr from Optical Absorption Thermoluminescence Studies of CaS Single Crystals in the Temperature Range 8 to 2 75 K Evidence of Schottky Barrier Formation at Contact oi Metal with Chalcogenide Glassy Semiconductor On the Sign Choice in the Darwin Solution for X-Ray Diffraction in a Semi-Infinite Crystal
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1