Body-Mass Index-Based Effective Dose Determination in Commonly Performed Computed Tomography Examinations in Adults

Q3 Health Professions Frontiers in Biomedical Technologies Pub Date : 2022-08-30 DOI:10.18502/fbt.v9i4.10425
M. Deevband, Seyyed Mohammad Bagher Hosseini Nasab, H. Mohammadi, Y. Salimi, A. Mostaar, N. Deravi, M. Fathi, K. Vakili, Shirin Yaghoobpoor, M. Ghorbani
{"title":"Body-Mass Index-Based Effective Dose Determination in Commonly Performed Computed Tomography Examinations in Adults","authors":"M. Deevband, Seyyed Mohammad Bagher Hosseini Nasab, H. Mohammadi, Y. Salimi, A. Mostaar, N. Deravi, M. Fathi, K. Vakili, Shirin Yaghoobpoor, M. Ghorbani","doi":"10.18502/fbt.v9i4.10425","DOIUrl":null,"url":null,"abstract":"Purpose: With the widespread application of ionizing radiation in medical practice, concerns have been increased regarding the hazardous effects of radiation. Studies have demonstrated that some variables such as body dimensions affect the absorbed radiation dose. In this study, the association between Body Mass Index (BMI) and absorbed dose in Computed Tomography (CT) is investigated. \nMaterials and Methods: A total of 550 adult patients (age ≥ 15 years) were included in the study. The height and weight of the patients were recorded for BMI calculation. Dosimetry data were acquired from digital imaging and communications in medicine dose reports. The patients were categorized into five groups according to their BMI, the categorized information was then imported into ImPACT Dose software for calculation of Size-Specific Dose Estimate (SSDE) and organ and effective doses. The relationship between patient BMI and the effective dose was also determined. \nResults: A higher BMI contributed to increased radiation dose and SSDE in patients who had undergone chest or abdomen-pelvis CT examination (p < 0.05).   \nConclusion: The radiation dose is related to a patient’s BMI and rises with an increase in BMI. Accordingly, it is suggested that BMI and other variables, such as the type of scan and other body dimensions, which affect the radiation dose, can be used to estimate the radiation dose before performing CT. This estimation can be considered for the justification and optimization of CT examinations.","PeriodicalId":34203,"journal":{"name":"Frontiers in Biomedical Technologies","volume":"9 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2022-08-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Frontiers in Biomedical Technologies","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.18502/fbt.v9i4.10425","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Health Professions","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: With the widespread application of ionizing radiation in medical practice, concerns have been increased regarding the hazardous effects of radiation. Studies have demonstrated that some variables such as body dimensions affect the absorbed radiation dose. In this study, the association between Body Mass Index (BMI) and absorbed dose in Computed Tomography (CT) is investigated. Materials and Methods: A total of 550 adult patients (age ≥ 15 years) were included in the study. The height and weight of the patients were recorded for BMI calculation. Dosimetry data were acquired from digital imaging and communications in medicine dose reports. The patients were categorized into five groups according to their BMI, the categorized information was then imported into ImPACT Dose software for calculation of Size-Specific Dose Estimate (SSDE) and organ and effective doses. The relationship between patient BMI and the effective dose was also determined. Results: A higher BMI contributed to increased radiation dose and SSDE in patients who had undergone chest or abdomen-pelvis CT examination (p < 0.05).   Conclusion: The radiation dose is related to a patient’s BMI and rises with an increase in BMI. Accordingly, it is suggested that BMI and other variables, such as the type of scan and other body dimensions, which affect the radiation dose, can be used to estimate the radiation dose before performing CT. This estimation can be considered for the justification and optimization of CT examinations.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
基于身体质量指数的有效剂量测定在成人常用计算机断层扫描检查中的应用
目的:随着电离辐射在医疗实践中的广泛应用,人们越来越关注辐射的有害影响。研究表明,一些变量,如身体尺寸影响吸收的辐射剂量。在本研究中,研究了身体质量指数(BMI)与计算机断层扫描(CT)吸收剂量之间的关系。材料与方法:共纳入550例年龄≥15岁的成人患者。记录患者的身高和体重,计算BMI。剂量学数据来自医学剂量报告中的数字成像和通信。根据BMI指数将患者分为5组,将分类信息输入ImPACT Dose软件,计算大小特异性剂量估算(SSDE)和器官有效剂量。确定了患者BMI与有效剂量之间的关系。结果:接受胸部或腹部骨盆CT检查的患者,BMI越高,放射剂量和SSDE越高(p < 0.05)。结论:放射剂量与患者的BMI有关,并随BMI的升高而升高。因此,建议在进行CT前,可以利用BMI和其他影响辐射剂量的变量,如扫描类型和其他身体尺寸,来估算辐射剂量。这一估计可作为CT检查的依据和优化。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Frontiers in Biomedical Technologies
Frontiers in Biomedical Technologies Health Professions-Medical Laboratory Technology
CiteScore
0.80
自引率
0.00%
发文量
34
审稿时长
12 weeks
期刊最新文献
AI in Nuclear Medical Applications: Challenges and Opportunities Evaluation of Eye-Blinking Dynamics in Human Emotion Recognition Using Weighted Visibility Graph Assessment of SPECT Image Reconstruction in Liver Scanning Using 99mTc/ EDDA/ HYNIC-TOCAssessment of SPECT Image Reconstruction in Liver Scanning Using 99mTc/ EDDA/ HYNIC-TOC Analysis of the Prevalence of Lumbar Annular Tears in Adult Patients Using Magnetic Resonance Imaging Data Grading the Dominant Pathological Indices in Liver Diseases from Pathological Images Using Radiomics Methods
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1