Development of a Chemically Modified Electrode with Magnetic Molecularly Imprinted Polymer (MagMIP) for 17-β-Estradiol Determination in Water Samples

Daniela Nunes da Silva, A. Pereira
{"title":"Development of a Chemically Modified Electrode with Magnetic Molecularly Imprinted Polymer (MagMIP) for 17-β-Estradiol Determination in Water Samples","authors":"Daniela Nunes da Silva, A. Pereira","doi":"10.3390/electrochem3040053","DOIUrl":null,"url":null,"abstract":"The present work consisted of the development of an electrode based on carbon paste modified with magnetic molecularly imprinted polymer (CPE-MagMIP) for 17-β-estradiol (E2) detection. The incorporation of magnetic material (MagMIP) improved sensor performance, an increase of over 317%. The proposed method resulted in a linear response range from 0.5 to 14.0 μM, and the detection limit (LOD) and quantification limit (LOQ) were equal to 0.13 and 0.44 μM, respectively. Under optimized conditions, the developed sensor obtained satisfactory parameters in E2 determination in water samples, demonstrating selectivity, accuracy, and precision, making it a promising method for monitoring E2 in environmental samples.","PeriodicalId":11612,"journal":{"name":"Electrochem","volume":"61 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2022-12-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Electrochem","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3390/electrochem3040053","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The present work consisted of the development of an electrode based on carbon paste modified with magnetic molecularly imprinted polymer (CPE-MagMIP) for 17-β-estradiol (E2) detection. The incorporation of magnetic material (MagMIP) improved sensor performance, an increase of over 317%. The proposed method resulted in a linear response range from 0.5 to 14.0 μM, and the detection limit (LOD) and quantification limit (LOQ) were equal to 0.13 and 0.44 μM, respectively. Under optimized conditions, the developed sensor obtained satisfactory parameters in E2 determination in water samples, demonstrating selectivity, accuracy, and precision, making it a promising method for monitoring E2 in environmental samples.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
磁性分子印迹聚合物化学修饰电极测定水样中17-β-雌二醇的研究
本文主要研究了磁性分子印迹聚合物修饰碳糊电极(CPE-MagMIP)对17-β-雌二醇(E2)的检测。磁性材料(MagMIP)的加入提高了传感器的性能,提高了317%以上。该方法的线性响应范围为0.5 ~ 14.0 μM,检测限(LOD)和定量限(LOQ)分别为0.13和0.44 μM。在优化条件下,所研制的传感器在水样中E2的测定中获得了满意的参数,具有良好的选择性、准确性和精密度,是一种很有前景的环境样品中E2监测方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
6.30
自引率
0.00%
发文量
0
期刊最新文献
Reduced Graphene Oxide Decorated Titanium Nitride Nanorod Array Electrodes for Electrochemical Applications High C-Rate Performant Electrospun LiFePO4/Carbon Nanofiber Self-Standing Cathodes for Lithium-Ion Batteries Supercritical CO2-Assisted Electroless Plating of Ultrahigh-Molecular-Weight Polyethylene Filaments for Weavable Device Application Ion-Selective Electrodes in the Food Industry: Development Trends in the Potentiometric Determination of Ionic Pollutants Determining the Oxidation Stability of Electrolytes for Lithium-Ion Batteries Using Quantum Chemistry and Molecular Dynamics
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1