Measurement of Outdoor and Indoor Background Ionizing Radiation of O.B. Lulu Briggs Health Center, University of Port Harcourt, Choba, Rivers State, Nigeria

B. O., Lulu Briggs, A. Bubu, C. Ononugbo
{"title":"Measurement of Outdoor and Indoor Background Ionizing Radiation of O.B. Lulu Briggs Health Center, University of Port Harcourt, Choba, Rivers State, Nigeria","authors":"B. O., Lulu Briggs, A. Bubu, C. Ononugbo","doi":"10.9734/ajopacs/2023/v11i3203","DOIUrl":null,"url":null,"abstract":"Measurement of outdoor and indoor background ionizing radiation (BIR) of O.B. Lulu Briggs Health Centre in the University of Port Harcourt, Rivers State, Nigeria was carried out using a well-calibrated Radalert-100 (Radiation meter) and Digilert-200 meters and Global Positioning System (Garmin 765). 30 selected locations were considered. The outdoor and indoor results are as follows respectively, average exposure rates are 0.012±0.001 and 0.013±0.001 mR/h, mean absorbed dose rate (ADR) are 105.6 and 96.28 nGy/h, estimated value of the annual effective dose equivalent (AEDE) are 0.17 and 0.27 mSv/y and mean excess lifetime cancer risk (ELCR) are (0.60 and 0.92) x 10-3. The obtained values for BIR in O.B. Lulu Briggs Health Centre are not above the recommended standard limit of 0.013mR/h by International Commission on Radiological protection (ICRP). AEDE that was calculated in the entire O.B. Lulu Briggs Health Centre is within safe values, the ELCR and the ADR estimated were higher than the world permissible values of 0.29 x 10-3 and 84.0 nGy/h respectively. The calculated dose to organs for O.B. Lulu Briggs showed that the testes have the highest organ dose of (0.140667 and 0.218053) mSv/y for outdoor and indoor respectively.","PeriodicalId":8541,"journal":{"name":"Asian Journal of Physical and Chemical Sciences","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2023-06-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Asian Journal of Physical and Chemical Sciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.9734/ajopacs/2023/v11i3203","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Measurement of outdoor and indoor background ionizing radiation (BIR) of O.B. Lulu Briggs Health Centre in the University of Port Harcourt, Rivers State, Nigeria was carried out using a well-calibrated Radalert-100 (Radiation meter) and Digilert-200 meters and Global Positioning System (Garmin 765). 30 selected locations were considered. The outdoor and indoor results are as follows respectively, average exposure rates are 0.012±0.001 and 0.013±0.001 mR/h, mean absorbed dose rate (ADR) are 105.6 and 96.28 nGy/h, estimated value of the annual effective dose equivalent (AEDE) are 0.17 and 0.27 mSv/y and mean excess lifetime cancer risk (ELCR) are (0.60 and 0.92) x 10-3. The obtained values for BIR in O.B. Lulu Briggs Health Centre are not above the recommended standard limit of 0.013mR/h by International Commission on Radiological protection (ICRP). AEDE that was calculated in the entire O.B. Lulu Briggs Health Centre is within safe values, the ELCR and the ADR estimated were higher than the world permissible values of 0.29 x 10-3 and 84.0 nGy/h respectively. The calculated dose to organs for O.B. Lulu Briggs showed that the testes have the highest organ dose of (0.140667 and 0.218053) mSv/y for outdoor and indoor respectively.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
O.B. Lulu Briggs健康中心室外和室内本底电离辐射测量,哈科特港大学,乔巴,河流州,尼日利亚
利用校准良好的Radalert-100(辐射计)和Digilert-200米以及全球定位系统(Garmin 765),对尼日利亚河流州哈科特港大学O.B. Lulu Briggs健康中心的室外和室内本底电离辐射(BIR)进行了测量。审议了30个选定地点。室外和室内结果分别为:平均暴露率分别为0.012±0.001和0.013±0.001 mR/h,平均吸收剂量率(ADR)分别为105.6和96.28 nGy/h,年有效剂量当量(AEDE)估计值分别为0.17和0.27 mSv/y,平均过量终身癌症风险(ELCR)分别为(0.60和0.92)× 10-3。在O.B. Lulu Briggs健康中心获得的BIR值不超过国际放射防护委员会(ICRP)建议的0.013mR/h标准限值。在整个O.B. Lulu Briggs健康中心计算的AEDE在安全范围内,估计的ELCR和ADR分别高于世界允许值0.29 x 10-3和84.0 nGy/h。露露布里格斯对器官的剂量计算表明,室外和室内的睾丸器官剂量最高,分别为(0.140667和0.218053)mSv/y。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Extraction, Evaluation, and Formulation of Hyptis capitata Jacq. (Burunganon) Flower Crude Extract as Bactericidal Ointment Determination of the Sulfur Content of Gasoline from Four Major Fuel Distributors in Dakar Dynamics of Planets and Other Celestial Bodies Proximate, Phytochemical and Gas Chromatography-mass Spectrometry (GC-MS) Analysis of the Carbonated Drink (Soft drink) Extract of Enantia chlorantha Stem Bark Realization and Experimental Study of a Forced Convection Solar Dryer
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1