Research on the technology of flame spraying aluminum coating for composite material

Q. Guo, Junjun Zhu, C. Li, P. Tang, C. Wen, Lan Liu, Tianze Wang, Yeqin Hu, Yingnan Zhao, M. Zhao, Yulong Feng, Hengyuan Xu, Haizhou Liu
{"title":"Research on the technology of flame spraying aluminum coating for composite material","authors":"Q. Guo, Junjun Zhu, C. Li, P. Tang, C. Wen, Lan Liu, Tianze Wang, Yeqin Hu, Yingnan Zhao, M. Zhao, Yulong Feng, Hengyuan Xu, Haizhou Liu","doi":"10.1177/26349833231159145","DOIUrl":null,"url":null,"abstract":"Aluminum coating was prepared on composite material surface by using oxygen-acetylene flame spraying technology. The H01-103H sealants were used to seal the thermal sprayed aluminum coatings. The characteristics of the aluminum coatings with and without H01-103H sealant, including surface morphologies, phase composition, and bonding strength, were investigated by means of SEM, EDS, and mechanical testing machine. Thermal shock experiment and low temperature cooling test were also used to examine the thermal shock resistance and frost resistance of the Al coatings. Electrical conductivity and electromagnetic shielding properties were then tested according to four-probe measurement principle and GJB 5239-2004, respectively. The results showed that the bond strength was 7.36 MPa and the surface porosity was about 5.21% for Al coating without H01-103H sealant, in addition, the H01-103H sealants could fill into the pores, reducing the porosity and increasing the bond strength of the coating. Furthermore, the main component of the coating was Al, the oxygen content was only 1.43%. Flame sprayed aluminum coating, with surface electrical resistance 0.89 mΩ and 5–18 GHz electromagnetic shielding effectiveness above 35 dB, was an ideal candidate for electromagnetic shielding utilization. The Al coating remained intact, compact, no cracks, peeling, layering under 50–200°C and −30°C, which showed good thermal shock resistance and frost resistance.","PeriodicalId":10608,"journal":{"name":"Composites and Advanced Materials","volume":"14 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-02-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Composites and Advanced Materials","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/26349833231159145","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Aluminum coating was prepared on composite material surface by using oxygen-acetylene flame spraying technology. The H01-103H sealants were used to seal the thermal sprayed aluminum coatings. The characteristics of the aluminum coatings with and without H01-103H sealant, including surface morphologies, phase composition, and bonding strength, were investigated by means of SEM, EDS, and mechanical testing machine. Thermal shock experiment and low temperature cooling test were also used to examine the thermal shock resistance and frost resistance of the Al coatings. Electrical conductivity and electromagnetic shielding properties were then tested according to four-probe measurement principle and GJB 5239-2004, respectively. The results showed that the bond strength was 7.36 MPa and the surface porosity was about 5.21% for Al coating without H01-103H sealant, in addition, the H01-103H sealants could fill into the pores, reducing the porosity and increasing the bond strength of the coating. Furthermore, the main component of the coating was Al, the oxygen content was only 1.43%. Flame sprayed aluminum coating, with surface electrical resistance 0.89 mΩ and 5–18 GHz electromagnetic shielding effectiveness above 35 dB, was an ideal candidate for electromagnetic shielding utilization. The Al coating remained intact, compact, no cracks, peeling, layering under 50–200°C and −30°C, which showed good thermal shock resistance and frost resistance.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
复合材料火焰喷涂镀铝工艺研究
采用氧乙炔火焰喷涂技术在复合材料表面制备了铝涂层。采用H01-103H密封胶对热喷涂铝涂层进行密封。采用扫描电镜(SEM)、能谱仪(EDS)和力学试验机研究了添加和不添加H01-103H密封胶的铝涂层的表面形貌、相组成和结合强度。通过热冲击试验和低温冷却试验,考察了铝涂层的抗热冲击性能和抗冻性能。然后分别按照四探头测量原理和GJB 5239-2004测试导电性能和电磁屏蔽性能。结果表明:未添加H01-103H密封剂的铝涂层,其结合强度为7.36 MPa,表面孔隙率约为5.21%,且H01-103H密封剂可以填充孔隙,降低孔隙率,提高涂层的结合强度。涂层的主要成分为Al,氧含量仅为1.43%。火焰喷涂铝涂层表面电阻0.89 mΩ, 5-18 GHz的电磁屏蔽效能在35 dB以上,是电磁屏蔽利用的理想候选者。在50-200℃和- 30℃条件下,Al涂层保持完整、致密、无裂纹、剥落、分层,表现出良好的抗热震性和抗冻性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Performance of blockboard using particle composite bagasse waste as core layer materials Vibration studies of an axially moving epoxy-carbon nanofiber composite beam in thermal environment—Effect of various nanofiber reinforcements Evaluation of fatigue life of fiberglass reinforced polyester composite materials using Weibull analysis methods Performance analysis of similar and dissimilar self-piercing riveted joints in aluminum alloys Characterization of animal shells-derived hydroxyapatite reinforced epoxy bio-composites
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1