Comparison of PD characteristics and degradation in PET insulation with vented and unvented voids

D. Adhikari, D. Hepburn, B. Stewart
{"title":"Comparison of PD characteristics and degradation in PET insulation with vented and unvented voids","authors":"D. Adhikari, D. Hepburn, B. Stewart","doi":"10.1109/CEIDP.2011.6232690","DOIUrl":null,"url":null,"abstract":"Partial Discharge (PD) results from faults in power insulation systems and exacerbates failure. It is known that the presence of voids in solid and liquid insulation give rise to PD. Factors which control the PD activity include pressure and type of gas present. When PD occurs in insulation, pressure is created and gaseous products changed due to the energy input. A series of experiments is being carried out on artificial voids, created from layered sections of polymer. One set of samples has a void inside the polymer with no access to the outer atmosphere; a second set of samples is created with a vent connecting the void to the outer atmosphere. Both sample sets are stressed at the same electrical conditions for same period of time. Investigation of the physical and chemical differences and PD patterns recorded follows.","PeriodicalId":6317,"journal":{"name":"2011 Annual Report Conference on Electrical Insulation and Dielectric Phenomena","volume":"99 1","pages":"444-447"},"PeriodicalIF":0.0000,"publicationDate":"2011-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"7","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 Annual Report Conference on Electrical Insulation and Dielectric Phenomena","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CEIDP.2011.6232690","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 7

Abstract

Partial Discharge (PD) results from faults in power insulation systems and exacerbates failure. It is known that the presence of voids in solid and liquid insulation give rise to PD. Factors which control the PD activity include pressure and type of gas present. When PD occurs in insulation, pressure is created and gaseous products changed due to the energy input. A series of experiments is being carried out on artificial voids, created from layered sections of polymer. One set of samples has a void inside the polymer with no access to the outer atmosphere; a second set of samples is created with a vent connecting the void to the outer atmosphere. Both sample sets are stressed at the same electrical conditions for same period of time. Investigation of the physical and chemical differences and PD patterns recorded follows.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
有气孔和无气孔的PET绝缘的PD特性和降解的比较
局部放电(Partial Discharge, PD)是电力绝缘系统故障的主要原因,它会加剧绝缘系统的故障。众所周知,固体和液体绝缘中存在的空隙会引起局部放电。控制PD活性的因素包括存在的压力和气体类型。当PD在绝缘中发生时,会产生压力,并且由于能量输入而改变气体产物。一系列的人造空洞实验正在进行中,这些空洞是由聚合物的分层部分形成的。一组样品在聚合物内部有一个空隙,无法进入外部大气;第二组样品是用通风口将空洞与外部大气连接起来的。两组样品在相同的电气条件下承受相同时间的应力。调查的物理和化学差异和PD模式记录如下。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Influence of A.C. electric field on plant growth Optimum D.C. electric field strength for growth acceleration of thale cress Feasibility study on the detection of corrosion of a cable metal shield using terahertz imaging Comparison of the effects of nanofiller materials on the dielectric properties of epoxy nanocomposites Diagnosis of cable aging by broadband impedance spectroscopy
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1