Z. Afshari, R. Ghoveizi, Layla Moein, Mahdi Shamali, S. Tavakolizadeh
{"title":"Dimensional accuracy of three impression materials by one-step and two-step impression techniques: An in vitro study","authors":"Z. Afshari, R. Ghoveizi, Layla Moein, Mahdi Shamali, S. Tavakolizadeh","doi":"10.22038/JDMT.2020.43747.1314","DOIUrl":null,"url":null,"abstract":"Introduction: An accurate impression is essential to create a well-fitted dental prosthesis. This study aimed to compare the dimensional accuracy of three elastomeric materials using one-step and two-step impression techniques. Methods: In this study, 20 impressions were fabricated for each Vinyl siloxane ether (Identium), condensation silicone (Speedex), and additional silicone (Panasil) impression materials by the one-step and two-step impression techniques using perforated metal trays. The one-step impression technique was simultaneously performed with heavy body/light-body materials. In the two-step impression technique, acrylic copings with 2-mm thickness were placed on the abutments to obtain similar spacing for the light-body material. The dimensional accuracy of different impression materials and techniques were measured using distance differences of the stone dies from the master cast; subsequently, the results were compared with the reference model. Data were analyzed using a one-way analysis of variance and Dunnett’s tests (α=0.05). Results: All impression materials demonstrated an acceptable clinical accuracy. Identium (Vinyl siloxane ether) displayed the most accuracy in both the one-step and two-step impression techniques (P>0.05). The best accuracy for Panasil (additional silicone) was found to be the two-step impression technique (P>0.05), and the best accuracy for Speedex (condensation silicone) was reported as the one-step impression technique (P>0.05). Furthermore, the one-step impression technique was highly accurate in diameter dimension, as compared to the two-step impression technique. Conclusion: As evidenced by the results, the accuracy of impression is affected by the impression materials. Moreover, Identium (Vinyl siloxane ether) demonstrated the most accuracy in both one-step and two-step impression techniques.","PeriodicalId":15640,"journal":{"name":"Journal of Dental Materials and Techniques","volume":"9 1","pages":"36-42"},"PeriodicalIF":0.0000,"publicationDate":"2020-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Dental Materials and Techniques","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.22038/JDMT.2020.43747.1314","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1
Abstract
Introduction: An accurate impression is essential to create a well-fitted dental prosthesis. This study aimed to compare the dimensional accuracy of three elastomeric materials using one-step and two-step impression techniques. Methods: In this study, 20 impressions were fabricated for each Vinyl siloxane ether (Identium), condensation silicone (Speedex), and additional silicone (Panasil) impression materials by the one-step and two-step impression techniques using perforated metal trays. The one-step impression technique was simultaneously performed with heavy body/light-body materials. In the two-step impression technique, acrylic copings with 2-mm thickness were placed on the abutments to obtain similar spacing for the light-body material. The dimensional accuracy of different impression materials and techniques were measured using distance differences of the stone dies from the master cast; subsequently, the results were compared with the reference model. Data were analyzed using a one-way analysis of variance and Dunnett’s tests (α=0.05). Results: All impression materials demonstrated an acceptable clinical accuracy. Identium (Vinyl siloxane ether) displayed the most accuracy in both the one-step and two-step impression techniques (P>0.05). The best accuracy for Panasil (additional silicone) was found to be the two-step impression technique (P>0.05), and the best accuracy for Speedex (condensation silicone) was reported as the one-step impression technique (P>0.05). Furthermore, the one-step impression technique was highly accurate in diameter dimension, as compared to the two-step impression technique. Conclusion: As evidenced by the results, the accuracy of impression is affected by the impression materials. Moreover, Identium (Vinyl siloxane ether) demonstrated the most accuracy in both one-step and two-step impression techniques.