{"title":"Efficacy and Safety of Conjunctival Cystectomy Using High-Frequency Radiowave Electrosurgery: A Preliminary Report.","authors":"M. Ji, Seung-Jun Lee, S. Han, J. Hyon","doi":"10.1097/ICL.0000000000000583","DOIUrl":null,"url":null,"abstract":"PURPOSE\nTo evaluate the efficacy and safety of conjunctival cystectomy using high-frequency radiowave electrosurgery.\n\n\nMETHODS\nThis retrospective study included 11 patients who underwent conjunctival cystectomy using high-frequency radiowave electrosurgery and had a follow-up of at least 6 months. Briefly, conjunctival opening with a diameter of 1 mm was made with using high-frequency radiowave electrosurgery (Ellman Surgitron; Ellman International, Inc., Hewlett, NY) in cut mode. The cyst was then extracted using a nontoothed forceps through the opening without rupture. Medical record of the patients was reviewed.\n\n\nRESULTS\nIn all the 11 patients, conjunctival wound healed in 1 week without any complication. No recurrence was detected in any patients over the 6-month follow-up.\n\n\nCONCLUSIONS\nConjunctival cystectomy with the adjunctive use of high-frequency radiowave electrosurgery was shown to be effective and safe.","PeriodicalId":12216,"journal":{"name":"Eye & Contact Lens: Science & Clinical Practice","volume":"29 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2019-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Eye & Contact Lens: Science & Clinical Practice","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1097/ICL.0000000000000583","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2
Abstract
PURPOSE
To evaluate the efficacy and safety of conjunctival cystectomy using high-frequency radiowave electrosurgery.
METHODS
This retrospective study included 11 patients who underwent conjunctival cystectomy using high-frequency radiowave electrosurgery and had a follow-up of at least 6 months. Briefly, conjunctival opening with a diameter of 1 mm was made with using high-frequency radiowave electrosurgery (Ellman Surgitron; Ellman International, Inc., Hewlett, NY) in cut mode. The cyst was then extracted using a nontoothed forceps through the opening without rupture. Medical record of the patients was reviewed.
RESULTS
In all the 11 patients, conjunctival wound healed in 1 week without any complication. No recurrence was detected in any patients over the 6-month follow-up.
CONCLUSIONS
Conjunctival cystectomy with the adjunctive use of high-frequency radiowave electrosurgery was shown to be effective and safe.