{"title":"A New Calibration Method of Line Scan Camera for High-Precision Two-Dimensional Measurement","authors":"Jiabin Zhang, Zhengtao Zhang, Fei Shen, Feng Zhang, Hu Su","doi":"10.1109/COASE.2018.8560438","DOIUrl":null,"url":null,"abstract":"In this paper, a calibration method for line scan cameras with image distortion is proposed to perform high-precision planar measurement. The intrinsic parameter model is presented according to the imaging work principle of the line scan camera. Moreover, an improved camera model is proposed via integrating the perspective transformation with the extrinsic parameter model in the consideration of image distortion resulting from the non-parallelism of motion direction and object plane. On this basis, the parameters in above model are calibrated based on nonlinear damping least square method with a planar chessboard pattern. A set of measurement experiments are conducted and the results verify the effectiveness of proposed approaches.","PeriodicalId":6518,"journal":{"name":"2018 IEEE 14th International Conference on Automation Science and Engineering (CASE)","volume":"86 1","pages":"678-683"},"PeriodicalIF":0.0000,"publicationDate":"2018-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 IEEE 14th International Conference on Automation Science and Engineering (CASE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/COASE.2018.8560438","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1
Abstract
In this paper, a calibration method for line scan cameras with image distortion is proposed to perform high-precision planar measurement. The intrinsic parameter model is presented according to the imaging work principle of the line scan camera. Moreover, an improved camera model is proposed via integrating the perspective transformation with the extrinsic parameter model in the consideration of image distortion resulting from the non-parallelism of motion direction and object plane. On this basis, the parameters in above model are calibrated based on nonlinear damping least square method with a planar chessboard pattern. A set of measurement experiments are conducted and the results verify the effectiveness of proposed approaches.