Including voltage dips mitigation in cost-benefit analysis of storages

G. Celli, F. Pilo, G. Pisano, G. G. Soma
{"title":"Including voltage dips mitigation in cost-benefit analysis of storages","authors":"G. Celli, F. Pilo, G. Pisano, G. G. Soma","doi":"10.1109/ICHQP.2018.8378907","DOIUrl":null,"url":null,"abstract":"Energy storage systems are valuable components of the future Smart Distribution Systems, thanks to their ability to increase the flexibility of the overall system and to provide a wide range of services. Unfortunately, their costs are still high and their profitable implementation has to be carefully justified. Voltage dips are the most common power quality disturbance in distribution networks. Their mitigation can be obtained by reinforcing the networks, i.e. by substituting overhead lines, with high fault rates, with buried cables, or, more easily, by installing custom power devices, as Dynamic Voltage Restorers (DVR) able to supply the needed energy to the protected customers during the dip. Among other services, energy storage systems can perform the same task of DVRs against the voltage dips and this benefit can contribute to make cost-effective their investment. The paper proposes an approach to estimate the benefit derived by the use of storages as DVR for reducing the expected number of voltage dips suffered by the customers. The obtained revenue can be added to the total benefit ascribable to the storage.","PeriodicalId":6506,"journal":{"name":"2018 18th International Conference on Harmonics and Quality of Power (ICHQP)","volume":"22 1","pages":"1-6"},"PeriodicalIF":0.0000,"publicationDate":"2018-05-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 18th International Conference on Harmonics and Quality of Power (ICHQP)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICHQP.2018.8378907","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

Abstract

Energy storage systems are valuable components of the future Smart Distribution Systems, thanks to their ability to increase the flexibility of the overall system and to provide a wide range of services. Unfortunately, their costs are still high and their profitable implementation has to be carefully justified. Voltage dips are the most common power quality disturbance in distribution networks. Their mitigation can be obtained by reinforcing the networks, i.e. by substituting overhead lines, with high fault rates, with buried cables, or, more easily, by installing custom power devices, as Dynamic Voltage Restorers (DVR) able to supply the needed energy to the protected customers during the dip. Among other services, energy storage systems can perform the same task of DVRs against the voltage dips and this benefit can contribute to make cost-effective their investment. The paper proposes an approach to estimate the benefit derived by the use of storages as DVR for reducing the expected number of voltage dips suffered by the customers. The obtained revenue can be added to the total benefit ascribable to the storage.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
在存储的成本效益分析中包括电压下降的缓解
储能系统是未来智能配电系统的重要组成部分,因为它们能够增加整个系统的灵活性,并提供广泛的服务。不幸的是,它们的成本仍然很高,而且它们的盈利实施必须谨慎地加以证明。电压跌落是配电网中最常见的电能质量扰动。通过加强电网,即用埋地电缆取代高故障率的架空线路,或者更容易的是,通过安装定制的电力设备,作为动态电压恢复器(DVR),能够在下降期间向受保护的客户提供所需的能量,从而减轻它们的影响。在其他服务中,储能系统可以针对电压下降执行与dvr相同的任务,这一优势可以使其投资具有成本效益。本文提出了一种方法来估计使用存储作为DVR的好处,以减少客户遭受的预期电压下降次数。获得的收益可以加到存储的总收益中。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Adaptive segmentation and machine learning based potential DR capacity analysis Harmonic resonance risk of massive ultra fast charging station grid integration A general process recommended by CIGRE WG C4.27 for benchmarking power quality performance in transmission systems On the limitations of harmonic modeling with measured inputs - a case study Analysis of replacement from disconnecting switch to circuit breaker for 500 kV line shunt reactor
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1