Local in-situ hydrophilic treatment of micro-channels using surface discharge

M. Gunji, H. Nakanishi, M. Washizu
{"title":"Local in-situ hydrophilic treatment of micro-channels using surface discharge","authors":"M. Gunji, H. Nakanishi, M. Washizu","doi":"10.1109/SENSOR.2005.1497290","DOIUrl":null,"url":null,"abstract":"In this paper, we describe a new method of local hydrophilic treatment of polymer micro-channel using surface discharge generated by a micro-electrode array. The method uses a pair of interdigitating electrodes embedded beneath a hydrophobic polymer (e.g. PDMS) micro-channel. When RF voltage is applied to the electrodes, surface discharge occurs inside the channel, and its inside surface is modified to be hydrophilic. Because the diffusion length of the generated plasma is only a few tens of micrometers, the treatment is local and selective. By using such a hydrophobic/hydrophilic patterning method, a droplet dispenser is developed. A straight PDMS channel having a side branch at the middle is fabricated, and the hydrophilic treatment is applied to the straight part. Due to capillary force, water solution fed from one end of the channel fills the entire straight channel, and when air is fed from the side, the liquid is divided into two parts, one ejected from the outlet. The ejection releases the pressure, and the channel is refilled, ready for the next ejection. The process produces a series of droplets, whose volume is precisely determined by the volume of the hydrophilic channel.","PeriodicalId":22359,"journal":{"name":"The 13th International Conference on Solid-State Sensors, Actuators and Microsystems, 2005. Digest of Technical Papers. TRANSDUCERS '05.","volume":"101 1","pages":"1187-1190 Vol. 2"},"PeriodicalIF":0.0000,"publicationDate":"2005-06-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The 13th International Conference on Solid-State Sensors, Actuators and Microsystems, 2005. Digest of Technical Papers. TRANSDUCERS '05.","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SENSOR.2005.1497290","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

In this paper, we describe a new method of local hydrophilic treatment of polymer micro-channel using surface discharge generated by a micro-electrode array. The method uses a pair of interdigitating electrodes embedded beneath a hydrophobic polymer (e.g. PDMS) micro-channel. When RF voltage is applied to the electrodes, surface discharge occurs inside the channel, and its inside surface is modified to be hydrophilic. Because the diffusion length of the generated plasma is only a few tens of micrometers, the treatment is local and selective. By using such a hydrophobic/hydrophilic patterning method, a droplet dispenser is developed. A straight PDMS channel having a side branch at the middle is fabricated, and the hydrophilic treatment is applied to the straight part. Due to capillary force, water solution fed from one end of the channel fills the entire straight channel, and when air is fed from the side, the liquid is divided into two parts, one ejected from the outlet. The ejection releases the pressure, and the channel is refilled, ready for the next ejection. The process produces a series of droplets, whose volume is precisely determined by the volume of the hydrophilic channel.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
表面放电微通道局部原位亲水处理
本文介绍了一种利用微电极阵列产生的表面放电对聚合物微通道进行局部亲水性处理的新方法。该方法使用一对交叉电极嵌入在疏水性聚合物(例如PDMS)微通道下。当对电极施加射频电压时,沟道内部发生表面放电,其内表面被修饰为亲水性。由于产生的等离子体的扩散长度只有几十微米,所以处理是局部的和选择性的。利用这种疏水/亲水性图图化方法,研制了液滴分配器。制造在中间具有侧分支的直PDMS通道,并对直部分进行亲水性处理。由于毛细力的作用,从通道一端进料的水溶液充满整个直通道,当从一侧进料时,液体被分成两部分,一部分从出口喷出。弹射释放压力,通道被重新填充,为下一次弹射做好准备。这个过程产生一系列的液滴,其体积精确地取决于亲水通道的体积。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
A new capacitive displacement sensor with high accuracy and long range Novel NDIR CO/sub 2/ sensor for indoor air quality monitoring A thin film strip for aerodynamic body pressure profile monitoring High power electrostatic motor with micropatterned electret on shrouded turbine Implantable blood pressure monitoring of small animal for advanced biological research
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1