{"title":"Effect of Sensor Failure on Dynamometry Calibration","authors":"N. Vlajic, Michael L. Jonson, M. Guers","doi":"10.1115/IMECE2020-24264","DOIUrl":null,"url":null,"abstract":"\n Dynamometers are used to measure integrated fluid dynamic loads such as thrust, torque or side forces. To resolve all of three force and three moment components, multiple embedded force gages are often used. Due to arrangement, static loads, and redundancy, the number of sensor channels can exceed the six degrees of freedom needed to resolve the generalized rigid body forces. This paper considers modeling of the force gages as simple springs to develop an elastic model of the dynamometer. The method was applied to a dynamometer consisting of six three-component force gages arranged in an axisymmetric ring. A calibration matrix based on the elastic model with individual force gage sensitivities was shown to match a full calibration matrix where properly summed force gage voltages were obtained under global load application. The elastic model was then extended to consider calibration matrices where sensors were assumed to fail. In this scenario, several virtual loads were applied to the dynamometer and the calibration matrix was obtained by minimizing the least square error. It was found that nearly half of the sensors could be lost and still a virtual calibration could be applied to the measurements. Extending the least square idea, an actual in-situ calibration matrix was formed by striking the dynamometer with a diverse set of instrumented hammer strikes. This calibration matrix also agreed with the other calibrations at frequencies below where system dynamics become important.","PeriodicalId":23648,"journal":{"name":"Volume 1: Acoustics, Vibration, and Phononics","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2020-11-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Volume 1: Acoustics, Vibration, and Phononics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1115/IMECE2020-24264","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Dynamometers are used to measure integrated fluid dynamic loads such as thrust, torque or side forces. To resolve all of three force and three moment components, multiple embedded force gages are often used. Due to arrangement, static loads, and redundancy, the number of sensor channels can exceed the six degrees of freedom needed to resolve the generalized rigid body forces. This paper considers modeling of the force gages as simple springs to develop an elastic model of the dynamometer. The method was applied to a dynamometer consisting of six three-component force gages arranged in an axisymmetric ring. A calibration matrix based on the elastic model with individual force gage sensitivities was shown to match a full calibration matrix where properly summed force gage voltages were obtained under global load application. The elastic model was then extended to consider calibration matrices where sensors were assumed to fail. In this scenario, several virtual loads were applied to the dynamometer and the calibration matrix was obtained by minimizing the least square error. It was found that nearly half of the sensors could be lost and still a virtual calibration could be applied to the measurements. Extending the least square idea, an actual in-situ calibration matrix was formed by striking the dynamometer with a diverse set of instrumented hammer strikes. This calibration matrix also agreed with the other calibrations at frequencies below where system dynamics become important.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
传感器故障对测力校正的影响
测功机用于测量综合流体动力载荷,如推力、扭矩或侧力。为了解决所有三个力和三个力矩分量,通常使用多个嵌入式力计。由于布置、静态载荷和冗余,传感器通道的数量可以超过解析广义刚体力所需的6个自由度。本文考虑将测力计建模为简单的弹簧,建立了测力计的弹性模型。将该方法应用于由六个三分量测力计组成的轴对称环上。基于具有单个力计灵敏度的弹性模型的校准矩阵与完整的校准矩阵相匹配,其中在全局负载作用下获得适当的力计电压求和。然后将弹性模型扩展到考虑假设传感器失效的校准矩阵。在这种情况下,在测功机上施加多个虚拟载荷,并通过最小化最小二乘误差获得校准矩阵。结果发现,近一半的传感器可能会丢失,但仍然可以对测量结果进行虚拟校准。扩展最小二乘思想,通过用不同的仪表锤击形成一个实际的原位校准矩阵。该校准矩阵也与系统动力学变得重要的频率以下的其他校准一致。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
A Machine Learning Framework for Physics-Based Multi-Fidelity Modeling and Health Monitoring for a Composite Wing Design and Numerical Analysis of Locally-Resonant Meta-Lattice Structure for Vibration Attenuation Research on Testing Method and Device of Sensitivity Consistency of Acoustic Emission Sensors Unsupervised Online Anomaly Detection of Metal Additive Manufacturing Processes via a Statistical Time-Frequency Domain Approach Nonlinear Electro-Mechanical Impedance Spectroscopy for Comprehensive Monitoring of Carbon Fiber Reinforced Composite Laminates
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1