Receiver Operating Characteristics Analyses of Food and Drug Administration-Cleared Serological Assays for Natural Rubber Latex-Specific Immunoglobulin E Antibody

R. Biagini, E. Krieg, L. Pinkerton, R. Hamilton
{"title":"Receiver Operating Characteristics Analyses of Food and Drug Administration-Cleared Serological Assays for Natural Rubber Latex-Specific Immunoglobulin E Antibody","authors":"R. Biagini, E. Krieg, L. Pinkerton, R. Hamilton","doi":"10.1128/CDLI.8.6.1145-1149.2001","DOIUrl":null,"url":null,"abstract":"ABSTRACT Receiver operating characteristics (ROC) analyses to evaluate and compare the diagnostic accuracy of Food and Drug Administration (510K)-cleared natural rubber latex (NRL)-specific immunoglobulin E (IgE) antibody immunoassays have not been performed using well-characterized skin-testing reagents. Sera were collected from 311 subjects (131 latex puncture skin test [PST] positive and 180 PST negative). All masked, coded sera were analyzed for latex-specific IgE antibodies in the Diagnostic Products Corporation microplate AlaSTAT, HYCOR HY-TEC RAST, and Pharmacia-Upjohn CAP System RAST FEIA (CAP). Diagnostic accuracy was evaluated using GraphRoc for Windows software to construct and analyze ROC curves in relation to the subjects' PST status and the results of the immunoassays. The ROC areas under the curve (AUCs) ± standard error based on PST for the three diagnostic tests were 0.858 ± 0.024, 0.869 ± 0.024, and 0.924 ± 0.017, respectively, for AlaSTAT, CAP, and HY-TEC. The HY-TEC system had a significantly greater AUC based on PST than those observed for AlaSTAT (P < 0.05) and CAP (P < 0.05) analyses. When the diagnostic tests were probed as to the cutoffs giving maximal diagnostic efficiency compared to PST, CAP and AlaSTAT yielded values of <0.35 kU of allergen IgE (kUA)/liter and <0.35 kU/liter while the HY-TEC assay yielded 0.11 kU/liter. The diagnostic efficiencies based on PST in our cohort at these cutoffs were 87.1, 88.1, and 88.7%, respectively. The HY-TEC assay had a significantly greater AUC than CAP and AlaSTAT using PST as a diagnostic discriminator in our cohort. When the HY-TEC system was probed at its maximally efficient cutoff (0.11 kU/liter) versus HYCOR's recommended cutoff of 0.05 kU/liter, a loss of sensitivity of 8.4% was observed with a gain in specificity of 19.5%.","PeriodicalId":10395,"journal":{"name":"Clinical Diagnostic Laboratory Immunology","volume":"26 1","pages":"1145 - 1149"},"PeriodicalIF":0.0000,"publicationDate":"2001-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"31","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical Diagnostic Laboratory Immunology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1128/CDLI.8.6.1145-1149.2001","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 31

Abstract

ABSTRACT Receiver operating characteristics (ROC) analyses to evaluate and compare the diagnostic accuracy of Food and Drug Administration (510K)-cleared natural rubber latex (NRL)-specific immunoglobulin E (IgE) antibody immunoassays have not been performed using well-characterized skin-testing reagents. Sera were collected from 311 subjects (131 latex puncture skin test [PST] positive and 180 PST negative). All masked, coded sera were analyzed for latex-specific IgE antibodies in the Diagnostic Products Corporation microplate AlaSTAT, HYCOR HY-TEC RAST, and Pharmacia-Upjohn CAP System RAST FEIA (CAP). Diagnostic accuracy was evaluated using GraphRoc for Windows software to construct and analyze ROC curves in relation to the subjects' PST status and the results of the immunoassays. The ROC areas under the curve (AUCs) ± standard error based on PST for the three diagnostic tests were 0.858 ± 0.024, 0.869 ± 0.024, and 0.924 ± 0.017, respectively, for AlaSTAT, CAP, and HY-TEC. The HY-TEC system had a significantly greater AUC based on PST than those observed for AlaSTAT (P < 0.05) and CAP (P < 0.05) analyses. When the diagnostic tests were probed as to the cutoffs giving maximal diagnostic efficiency compared to PST, CAP and AlaSTAT yielded values of <0.35 kU of allergen IgE (kUA)/liter and <0.35 kU/liter while the HY-TEC assay yielded 0.11 kU/liter. The diagnostic efficiencies based on PST in our cohort at these cutoffs were 87.1, 88.1, and 88.7%, respectively. The HY-TEC assay had a significantly greater AUC than CAP and AlaSTAT using PST as a diagnostic discriminator in our cohort. When the HY-TEC system was probed at its maximally efficient cutoff (0.11 kU/liter) versus HYCOR's recommended cutoff of 0.05 kU/liter, a loss of sensitivity of 8.4% was observed with a gain in specificity of 19.5%.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
天然橡胶乳胶特异性免疫球蛋白E抗体经食品药品监督管理的血清学检测的受者操作特征分析
接受者工作特征(ROC)分析用于评估和比较美国食品和药物管理局(510K)清除的天然胶乳(NRL)特异性免疫球蛋白E (IgE)抗体免疫测定的诊断准确性,尚未使用表征良好的皮肤试验试剂进行。采集血清311例(乳胶穿刺皮肤试验[PST]阳性131例,PST阴性180例)。在诊断产品公司(Diagnostic Products Corporation) AlaSTAT、HYCOR HY-TEC RAST和Pharmacia-Upjohn CAP System RAST FEIA (CAP)中,对所有被屏蔽的编码血清进行乳胶特异性IgE抗体分析。使用GraphRoc for Windows软件评估诊断准确性,构建和分析受试者PST状态和免疫测定结果相关的ROC曲线。AlaSTAT、CAP和HY-TEC三种诊断指标基于PST的ROC曲线下面积(auc)±标准误差分别为0.858±0.024、0.869±0.024和0.924±0.017。HY-TEC系统基于PST的AUC显著高于AlaSTAT (P < 0.05)和CAP (P < 0.05)分析。与PST相比,CAP和AlaSTAT的诊断效率分别为<0.35 kU/l和<0.35 kU/l,而hyc - tec的诊断效率为0.11 kU/l。在我们的队列中,基于PST的诊断效率在这些截止点分别为87.1、88.1和88.7%。在我们的队列中,HY-TEC检测的AUC明显高于CAP和使用PST作为诊断鉴别器的AlaSTAT。当HY-TEC系统以其最大有效截止值(0.11 kU/l)与HYCOR推荐的0.05 kU/l截止值进行检测时,观察到灵敏度损失8.4%,特异性增加19.5%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Immunoglobulin G1 Antibody Response toHelicobacter pylori Heat Shock Protein 60 Is Closely Associated with Low-Grade Gastric Mucosa-Associated Lymphoid Tissue Lymphoma Antibodies against Streptococcus agalactiae Proteins cα and R4 in Sera from Pregnant Women from Norway and Zimbabwe Cystatin Capture Enzyme-Linked Immunosorbent Assay for Serodiagnosis of Human Clonorchiasis and Profile of Captured Antigenic Protein of Clonorchis sinensis Recognition of Multiple Classes of Hepatitis C Antibodies Increases Detection Sensitivity in Oral Fluid Circulating Inflammatory Mediators in Patients with Fever: Predicting Bloodstream Infection
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1