Clinical study of real-time polymerase chain reaction test kit for SARS-CoV-2 ribonucleic acids detection

M. Dmitryukova, A. A. Golod, M. Senina, A. E. Gushchin
{"title":"Clinical study of real-time polymerase chain reaction test kit for SARS-CoV-2 ribonucleic acids detection","authors":"M. Dmitryukova, A. A. Golod, M. Senina, A. E. Gushchin","doi":"10.17749/2070-4909/farmakoekonomika.2022.111","DOIUrl":null,"url":null,"abstract":"Objective: development and validation of a reverse transcription polymerase chain reaction (RT-PCR) test kit for SARS-CoV-2 ribonucleic acids (RNA) qualitative detection adapted for using with automated station for RNA extraction.Material and methods. Assessment of clinical performance was carried out on biological samples (nasal and oropharyngeal swabs and sputum) obtained during the diagnostic procedure. The presence of novel coronavirus RNA was established using a reference kit. Sensitivity was evaluated on standard SARS-CoV-2 sample (EDX SARS-CoV-2 Standard, Bio-Rad Laboratories, USA).Results. Presence of SARS-CoV-2 RNA is detected by two genome regions. Sensitivity determined by testing SARS-CoV-2 standard was 250 copies/ml. Coefficient of variation during the testing of samples with the concentration of 104 copies/ml did not exceed 5% in different conditions. Diagnostic sensitivity against reference test was 100% (95% confidence interval (CI) 95.6–100) for nasal and oropharyngeal swabs and 100% (95% CI 94.8–100) for sputum. Diagnostic specificity was 100% (95% CI 95.6–100) for nasal and oropharyngeal swabs and 100% (95% CI 94.8–100) for sputum. The turnaround time for test from RNA extraction till obtaining results was about 3 hours when testing 96 samples using automated stations for RNA extraction.Conclusion. Using the kit together with automated station for RNA extraction will increase laboratory testing capacity in pandemic conditions.","PeriodicalId":36464,"journal":{"name":"Farmakoekonomika","volume":"3 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2022-07-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Farmakoekonomika","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.17749/2070-4909/farmakoekonomika.2022.111","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: development and validation of a reverse transcription polymerase chain reaction (RT-PCR) test kit for SARS-CoV-2 ribonucleic acids (RNA) qualitative detection adapted for using with automated station for RNA extraction.Material and methods. Assessment of clinical performance was carried out on biological samples (nasal and oropharyngeal swabs and sputum) obtained during the diagnostic procedure. The presence of novel coronavirus RNA was established using a reference kit. Sensitivity was evaluated on standard SARS-CoV-2 sample (EDX SARS-CoV-2 Standard, Bio-Rad Laboratories, USA).Results. Presence of SARS-CoV-2 RNA is detected by two genome regions. Sensitivity determined by testing SARS-CoV-2 standard was 250 copies/ml. Coefficient of variation during the testing of samples with the concentration of 104 copies/ml did not exceed 5% in different conditions. Diagnostic sensitivity against reference test was 100% (95% confidence interval (CI) 95.6–100) for nasal and oropharyngeal swabs and 100% (95% CI 94.8–100) for sputum. Diagnostic specificity was 100% (95% CI 95.6–100) for nasal and oropharyngeal swabs and 100% (95% CI 94.8–100) for sputum. The turnaround time for test from RNA extraction till obtaining results was about 3 hours when testing 96 samples using automated stations for RNA extraction.Conclusion. Using the kit together with automated station for RNA extraction will increase laboratory testing capacity in pandemic conditions.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
实时聚合酶链反应试剂盒检测SARS-CoV-2核糖核酸的临床研究
目的:研制并验证一种适用于RNA自动提取工作站的SARS-CoV-2核糖核酸(RNA)定性检测的逆转录聚合酶链反应(RT-PCR)检测试剂盒。材料和方法。对诊断过程中获得的生物样本(鼻咽拭子和痰液)进行临床表现评估。使用参比试剂盒确定存在新型冠状病毒RNA。对标准SARS-CoV-2样品(EDX SARS-CoV-2 standard, Bio-Rad Laboratories, USA)进行敏感性评价。通过两个基因组区域检测SARS-CoV-2 RNA的存在。检测SARS-CoV-2标准品的灵敏度为250拷贝/ml。对于浓度为104拷贝/ml的样品,不同条件下的变异系数均不超过5%。鼻和口咽拭子对参考试验的诊断敏感性为100%(95%可信区间(CI) 95.6-100),痰液对参考试验的诊断敏感性为100% (95% CI 94.8-100)。鼻咽拭子的诊断特异性为100% (95% CI 95.6-100),痰液的诊断特异性为100% (95% CI 94.8-100)。采用RNA自动提取站对96份样品进行检测,从提取到得到结果所需时间约为3小时。将该试剂盒与自动RNA提取站一起使用将提高实验室在大流行条件下的检测能力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Farmakoekonomika
Farmakoekonomika Medicine-Health Policy
CiteScore
1.70
自引率
0.00%
发文量
43
审稿时长
8 weeks
期刊最新文献
Updated pharmacoeconomic analysis of atesolizumab efficiency compared with other PD-1 inhibitors in patients with advanced non-small cell lung cancer after chemotherapy Efficacy of alectinib in comparison with lorlatinib in patients with ALK-positive non-small cell lung cancer: pharmacoeconomic study Retrospective pharmacoeconomic study of antibiotic therapy in community-acquired pneumonia The role of ferritin in liver disease assessment An open-label, controlled trial of the clinical effects of Laennec® in patients with nonalcoholic steatohepatitis or cirrhosis
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1