CONDENSING LENS ON BINOCULAR INDIRECT OPHTHALMOSCOPY AND SLIT-LAMP BIOMICROSCOPY

Danang Yoga Wiguna, Sauli Ari Widjaja, Wimbo Sasono, Muhammad Firmansjah, Ima Yustiarini, Ady Dwi Prakosa, Moestidjab Moestidjab, Gatut Suhendro
{"title":"CONDENSING LENS ON BINOCULAR INDIRECT OPHTHALMOSCOPY AND SLIT-LAMP BIOMICROSCOPY","authors":"Danang Yoga Wiguna, Sauli Ari Widjaja, Wimbo Sasono, Muhammad Firmansjah, Ima Yustiarini, Ady Dwi Prakosa, Moestidjab Moestidjab, Gatut Suhendro","doi":"10.35479/ijretina.2019.vol002.iss002.76","DOIUrl":null,"url":null,"abstract":"Condensing lens is a lens used as an auxiliary lens in indirect instruments to examines the fundus. This lens is used with binocular indirect ophthalmoscope and slit-lamp biomicroscope to reach a stereopsis image of fundus. Optical principle of condensing lens is to make the eye in myopic condition, so it can producesa real, aerial, inverted and reversed image. This lens was placed between the instruments and the eye of the patient which located closer to patient’s eye. Optimalized position of the lens can produce a good fundus image. \nCondensing lens have so many power of dioptre that each power produces different magnification and field of view. High powered lenses produces wider field of view than low powered ones. High powered lens can also used in patient with small dilated pupil and shorter distance of examination. Low powered lenses offer more magnification. \nFundus examination with binocular indirect ophthalmoscope and slit-lamp biomicroscope have purpose to produces stereopsis image because of the binocularity system. These two instruments have each advantages and disadvantages. The advantages of binocular indirect ophthalmoscope are a portable instrument, relatively can be used in uncooperative patient and it can be used with scleral indentation to reach more peripheral view of the fundus. Meanwhile slit-lamp biomicroscope has the advantages to offer more magnification and flexible illumination system. With higher powered lens use in biomicroscope, it also give advantages in shorter distance of examination and wider field of view.","PeriodicalId":33128,"journal":{"name":"IJRETINA International Journal of Retina","volume":"69 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2019-09-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IJRETINA International Journal of Retina","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.35479/ijretina.2019.vol002.iss002.76","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

Condensing lens is a lens used as an auxiliary lens in indirect instruments to examines the fundus. This lens is used with binocular indirect ophthalmoscope and slit-lamp biomicroscope to reach a stereopsis image of fundus. Optical principle of condensing lens is to make the eye in myopic condition, so it can producesa real, aerial, inverted and reversed image. This lens was placed between the instruments and the eye of the patient which located closer to patient’s eye. Optimalized position of the lens can produce a good fundus image. Condensing lens have so many power of dioptre that each power produces different magnification and field of view. High powered lenses produces wider field of view than low powered ones. High powered lens can also used in patient with small dilated pupil and shorter distance of examination. Low powered lenses offer more magnification. Fundus examination with binocular indirect ophthalmoscope and slit-lamp biomicroscope have purpose to produces stereopsis image because of the binocularity system. These two instruments have each advantages and disadvantages. The advantages of binocular indirect ophthalmoscope are a portable instrument, relatively can be used in uncooperative patient and it can be used with scleral indentation to reach more peripheral view of the fundus. Meanwhile slit-lamp biomicroscope has the advantages to offer more magnification and flexible illumination system. With higher powered lens use in biomicroscope, it also give advantages in shorter distance of examination and wider field of view.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
双眼间接检眼镜和裂隙灯生物显微镜的冷凝透镜
晶状体是一种在间接检查眼底的仪器中用作辅助的晶状体。该晶体与双眼间接检眼镜和裂隙灯生物显微镜配合使用,可获得眼底立体图像。聚光透镜的光学原理是使眼睛处于近视眼的状态,从而产生真实的、空中的、倒立的、反向的影像。这种晶状体被放置在仪器和患者眼睛之间,靠近患者眼睛。优化晶状体位置可以获得良好的眼底图像。聚光透镜具有多种屈光度,每种屈光度都会产生不同的放大倍率和视场。高倍率镜头比低倍率镜头视野更宽。高倍镜也可用于瞳孔放大小、检查距离较短的患者。低倍率镜头提供更大的放大倍率。双目间接检眼底和裂隙灯生物显微镜检查眼底的目的是产生立体图像,因为双目系统。这两种工具各有优缺点。双眼间接检眼镜的优点是方便携带,相对而言可用于不配合患者,并可与巩膜压痕配合使用,以获得更多的眼底周边视野。同时,裂隙灯生物显微镜具有放大倍率高、照明系统灵活等优点。在生物显微镜中使用更高倍率的透镜,在更短的检查距离和更广阔的视野方面也具有优势。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
审稿时长
4 weeks
期刊最新文献
RARE CASE OF SPONTANEOUS SUB-RETINAL HAEMORRHAGE ASSOCIATED WITH IDOPATHIC INTRACRANIAL HYPERTENSION DAPSONE-INDUCED TOXIC MACULOPATHY IN LEPROSY PATIENT NEURODEVELOPMENTAL OUTCOMES AFTER ANTI-VEGF TREATMENT FOR RETINOPATHY OF PREMATURITY: A SYSTEMATIC REVIEW AND META-ANALYSIS CLINICAL OUTCOMES OF SURGERY FOR ADVANCED STAGE RETINOPATHY OF PREMATURITY: A CASE REPORT IS 360° INTRAOPERATIVE LASER RETINOPEXY AFTER PRIMARY PARS PLANA VITRECTOMY WORTHWHILE TO PREVENT RECURRENT RETINAL DETACHMENT?
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1