Low background measurement in CANDLES-III for studying the neutrinoless double beta decay of Ca48

S. Ajimura, W. M. Chan, K. Ichimura, T. Ishikawa, K. Kanagawa, B. T. Khai, T. Kishimoto, H. Kino, T. Maeda, K. Matsuoka, N. Nakatani, M. Nomachi, M. Saka, K. Seki, Y. Takemoto, Y. Takihira, D. Tanaka, M. Tanaka, K. Tetsuno, V. Trang, M. Tsuzuki, S. Umehara, K. Akutagawa, T. Batpurev, M. Doihara, S. Katagiri, E. Kinoshita, Y. Hirano, T. Iga, M. Ishikawa, G. Ito, H. Kakubata, K. Lee, X. Li, K. Mizukoshi, M. Moser, T. Ohata, M. Shokati, M. S. Soberi, T. Uehara, W. Wang, K. Yamamoto, K. Yasuda, S. Yoshida, N. Yotsunaga, T. Harada, H. Hiraoka, T. Hiyama, A. Hirota, Y. Ikeyama, A. Kawamura, Y. Kawashima, S. Maeda, K. Nakajima, I. Ogawa, K. Ozawa, K. Shamoto, K. Shimizu, Y. Shinki, Y. Tamagawa, M. Tozawa, M. Yoshizawa, K. Fushimi, R. Hazama, P. Noithong, A. Rittirong, K. Suzuki, T. Iida
{"title":"Low background measurement in CANDLES-III for studying the neutrinoless double beta decay of \nCa48","authors":"S. Ajimura, W. M. Chan, K. Ichimura, T. Ishikawa, K. Kanagawa, B. T. Khai, T. Kishimoto, H. Kino, T. Maeda, K. Matsuoka, N. Nakatani, M. Nomachi, M. Saka, K. Seki, Y. Takemoto, Y. Takihira, D. Tanaka, M. Tanaka, K. Tetsuno, V. Trang, M. Tsuzuki, S. Umehara, K. Akutagawa, T. Batpurev, M. Doihara, S. Katagiri, E. Kinoshita, Y. Hirano, T. Iga, M. Ishikawa, G. Ito, H. Kakubata, K. Lee, X. Li, K. Mizukoshi, M. Moser, T. Ohata, M. Shokati, M. S. Soberi, T. Uehara, W. Wang, K. Yamamoto, K. Yasuda, S. Yoshida, N. Yotsunaga, T. Harada, H. Hiraoka, T. Hiyama, A. Hirota, Y. Ikeyama, A. Kawamura, Y. Kawashima, S. Maeda, K. Nakajima, I. Ogawa, K. Ozawa, K. Shamoto, K. Shimizu, Y. Shinki, Y. Tamagawa, M. Tozawa, M. Yoshizawa, K. Fushimi, R. Hazama, P. Noithong, A. Rittirong, K. Suzuki, T. Iida","doi":"10.1103/PhysRevD.103.092008","DOIUrl":null,"url":null,"abstract":"We developed a CANDLES-III system using 96 CaF$_{2}$ scintillation crystals with a total mass of 305 kg to study the neutrino-less double beta (0$\\nu\\beta\\beta$) decay of $^{48}$Ca. The system was equipped with a 4$\\pi$ active shield using a liquid scintillator to reject external backgrounds. The internal backgrounds caused by the radioactive impurities within the CaF$_2$ crystals can be effectively reduced by observing the signal pulse shape. We analyzed the data observed in the Kamioka underground for the live-time of 130.4 days to evaluate the feasibility of the low background measurement with the CANDLES-III detector. Moreover, we estimated the number of background events from the simulation based on the radioactive impurities in the CaF$_{2}$ crystals and the rate of high energy $\\gamma$-rays caused by the (n, $\\gamma$) reaction induced by environmental neutrons. The expected background rate was in a good agreement with the measured rate. In conclusion, the background candidates were properly estimated by comparing the measured energy spectrum with the background simulations. Consequently, no events were observed in the Q$_{\\beta\\beta}$-value region when 21 high purity CaF$_{2}$ crystals were selected. This gave a lower limit on the half-life of T$^{0\\nu\\beta\\beta}_{1/2}$ $\\ge$ 5.6 $\\times$ 10$^{22}$ yr (90\\% confidence level) for the 0$\\nu\\beta\\beta$ decay of $^{48}$Ca. With this measurement, we achieved the first 0$\\nu\\beta\\beta$ decay search in a low background condition with a detector using a Ca isotope, which was not enriched but natural, in a scale of hundreds of kg. The $^{48}$Ca isotope has a high potential for the 0$\\nu\\beta\\beta$ decay search, and expected to be useful for the development of the next detector for a highly sensitive measurement.","PeriodicalId":8429,"journal":{"name":"arXiv: High Energy Physics - Experiment","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2020-08-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"8","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"arXiv: High Energy Physics - Experiment","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1103/PhysRevD.103.092008","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 8

Abstract

We developed a CANDLES-III system using 96 CaF$_{2}$ scintillation crystals with a total mass of 305 kg to study the neutrino-less double beta (0$\nu\beta\beta$) decay of $^{48}$Ca. The system was equipped with a 4$\pi$ active shield using a liquid scintillator to reject external backgrounds. The internal backgrounds caused by the radioactive impurities within the CaF$_2$ crystals can be effectively reduced by observing the signal pulse shape. We analyzed the data observed in the Kamioka underground for the live-time of 130.4 days to evaluate the feasibility of the low background measurement with the CANDLES-III detector. Moreover, we estimated the number of background events from the simulation based on the radioactive impurities in the CaF$_{2}$ crystals and the rate of high energy $\gamma$-rays caused by the (n, $\gamma$) reaction induced by environmental neutrons. The expected background rate was in a good agreement with the measured rate. In conclusion, the background candidates were properly estimated by comparing the measured energy spectrum with the background simulations. Consequently, no events were observed in the Q$_{\beta\beta}$-value region when 21 high purity CaF$_{2}$ crystals were selected. This gave a lower limit on the half-life of T$^{0\nu\beta\beta}_{1/2}$ $\ge$ 5.6 $\times$ 10$^{22}$ yr (90\% confidence level) for the 0$\nu\beta\beta$ decay of $^{48}$Ca. With this measurement, we achieved the first 0$\nu\beta\beta$ decay search in a low background condition with a detector using a Ca isotope, which was not enriched but natural, in a scale of hundreds of kg. The $^{48}$Ca isotope has a high potential for the 0$\nu\beta\beta$ decay search, and expected to be useful for the development of the next detector for a highly sensitive measurement.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
用candle - iii进行低本底测量,研究Ca48的中微子双β衰变
我们开发了一个CANDLES-III系统,使用96个总质量为305 kg的CaF $_{2}$闪烁晶体来研究$^{48}$ Ca的无中微子双β (0 $\nu\beta\beta$)衰变。该系统配备了一个4 $\pi$主动屏蔽,使用液体闪烁体来抑制外部背景。通过观察信号脉冲形状,可以有效地减小CaF $_2$晶体内部放射性杂质所引起的内部背景。通过对神冈地下130.4天的观测数据进行分析,评价了CANDLES-III探测器低本底测量的可行性。此外,我们根据CaF $_{2}$晶体中的放射性杂质和由环境中子诱导的(n, $\gamma$)反应引起的高能$\gamma$射线的速率,从模拟中估计了背景事件的数量。预期的背景速率与实测速率很好地吻合。综上所述,通过实测能谱与背景模拟结果的比较,对背景候选者进行了正确的估计。因此,当选择21个高纯度的CaF $_{2}$晶体时,在Q $_{\beta\beta}$值区域没有观察到任何事件。这给出了$^{48}$ Ca的0 $\nu\beta\beta$衰变的半衰期T $^{0\nu\beta\beta}_{1/2}$$\ge$ 5.6 $\times$ 10 $^{22}$ yr(90%置信水平)的下限。通过这一测量,我们在低背景条件下使用检测器实现了第一次0 $\nu\beta\beta$衰变搜索,该检测器使用的Ca同位素不是富集的,而是天然的,规模为数百公斤。$^{48}$ Ca同位素对0 $\nu\beta\beta$衰变搜索具有很高的潜力,并有望用于开发下一个高灵敏度测量的探测器。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
First direct neutrino-mass measurement with sub-eV sensitivity Search for invisible axion dark matter of mass ma=43  μeV with the QUAX– aγ experiment First measurement using a nuclear emulsion detector of the ν μ charged-current cross section on iron around the 1 GeV energy region Latest D0 results on exotic hadrons produced in $p\bar p $ collision Sensitivity improvement in hidden photon detection using resonant cavities
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1