Effect of spatial orientation on the image-intensifier distortion in quantitative coronary angiography

E. Gronenschild
{"title":"Effect of spatial orientation on the image-intensifier distortion in quantitative coronary angiography","authors":"E. Gronenschild","doi":"10.1109/CIC.1993.378332","DOIUrl":null,"url":null,"abstract":"The effect of spatial orientation of the X-ray gantry on the geometric image distortion caused by the image intensifier (II) is assessed. Variations in absolute positions up to 0.6 mm (14 cm II size), 1.1 mm (17 cm), and 2.8 mm (27 cm) are found for the used Hicor X-ray system. The pixel size varies up to 0.8% (14 cm), 1.1% (17 cm), and 2.3% (27 cm). It is concluded that for accurate quantitative coronary angiography and 3D reconstructions it is necessary to measure the distortion and to correct for it at each of the used orientations.<<ETX>>","PeriodicalId":20445,"journal":{"name":"Proceedings of Computers in Cardiology Conference","volume":"56 1","pages":"595-598"},"PeriodicalIF":0.0000,"publicationDate":"1993-09-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"9","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of Computers in Cardiology Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CIC.1993.378332","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 9

Abstract

The effect of spatial orientation of the X-ray gantry on the geometric image distortion caused by the image intensifier (II) is assessed. Variations in absolute positions up to 0.6 mm (14 cm II size), 1.1 mm (17 cm), and 2.8 mm (27 cm) are found for the used Hicor X-ray system. The pixel size varies up to 0.8% (14 cm), 1.1% (17 cm), and 2.3% (27 cm). It is concluded that for accurate quantitative coronary angiography and 3D reconstructions it is necessary to measure the distortion and to correct for it at each of the used orientations.<>
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
空间取向对定量冠状动脉造影图像增强器畸变的影响
评估了x射线龙门的空间取向对图像增强器(II)引起的几何图像畸变的影响。在使用的Hicor x射线系统中,绝对位置的变化可达0.6 mm (14 cm II尺寸),1.1 mm (17 cm)和2.8 mm (27 cm)。像素大小可达0.8%(14厘米)、1.1%(17厘米)和2.3%(27厘米)。由此得出结论,为了准确定量冠脉造影和三维重建,有必要在每个使用的方向上测量畸变并对其进行校正。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
A 528 channel system for the acquisition and display of defibrillation and electrocardiographic potentials Computers: the heart of screening Signal averaging enhancement by jitter deconvolution Numerical simulation of the flow in model skeletal muscle ventricles Transmembrane potential changes during stimulation in a bidomain model of the myocardium
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1