A Simulative and Experimental Approach Toward Eddy Current Nondestructive Evaluation of Manufacturing Flaws and Operational Damage in CFRP Composites

R. James, M. Haider, V. Giurgiutiu, David Lilienthal
{"title":"A Simulative and Experimental Approach Toward Eddy Current Nondestructive Evaluation of Manufacturing Flaws and Operational Damage in CFRP Composites","authors":"R. James, M. Haider, V. Giurgiutiu, David Lilienthal","doi":"10.1115/1.4044722","DOIUrl":null,"url":null,"abstract":"\n The manufacturing process of carbon fiber reinforced polymer (CFRP) composite structures can introduce many characteristic defects and flaws such as fiber misorientation, fiber waviness, and wrinkling. Therefore, it becomes increasingly important to detect the presence of these defects at the earliest stages of development. Eddy current testing (ECT) is a nondestructive inspection (NDI) technique that has been proven quite effective in detection of damage in metallic structures. However, NDI of composite structures has mainly relied on other methods such as ultrasonic testing (UT) and X-ray to name a few and not much on ECT. In this paper, the authors explore the possibility of using ECT in NDI of CFRP composites by conducting simulations and experiments thereafter. This research is based on the fact that the CFRP displays some low-level electrical conductivity due to the inherent conductivity of the carbon fibers. This low-level conductivity may permit eddy current pathways to cause the flow of eddy currents in the CFRP composites that can be exploited for nondestructive damage detection. An invention disclosure describing our high-frequency ECT method has also been processed. First, the multiphysics finite element method (FEM) simulation was used to simulate the detection of various types of manufacturing flaws and operational damage in CFRP composites such as fiber misorientation, waviness, wrinkling, and so on. Thereafter, ECT experiments were conducted on CFRP specimens with various manufacturing flaws using the Eddyfi Reddy eddy current array (ECA) system.","PeriodicalId":52294,"journal":{"name":"Journal of Nondestructive Evaluation, Diagnostics and Prognostics of Engineering Systems","volume":"9 1","pages":""},"PeriodicalIF":2.0000,"publicationDate":"2019-09-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"24","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Nondestructive Evaluation, Diagnostics and Prognostics of Engineering Systems","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1115/1.4044722","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 24

Abstract

The manufacturing process of carbon fiber reinforced polymer (CFRP) composite structures can introduce many characteristic defects and flaws such as fiber misorientation, fiber waviness, and wrinkling. Therefore, it becomes increasingly important to detect the presence of these defects at the earliest stages of development. Eddy current testing (ECT) is a nondestructive inspection (NDI) technique that has been proven quite effective in detection of damage in metallic structures. However, NDI of composite structures has mainly relied on other methods such as ultrasonic testing (UT) and X-ray to name a few and not much on ECT. In this paper, the authors explore the possibility of using ECT in NDI of CFRP composites by conducting simulations and experiments thereafter. This research is based on the fact that the CFRP displays some low-level electrical conductivity due to the inherent conductivity of the carbon fibers. This low-level conductivity may permit eddy current pathways to cause the flow of eddy currents in the CFRP composites that can be exploited for nondestructive damage detection. An invention disclosure describing our high-frequency ECT method has also been processed. First, the multiphysics finite element method (FEM) simulation was used to simulate the detection of various types of manufacturing flaws and operational damage in CFRP composites such as fiber misorientation, waviness, wrinkling, and so on. Thereafter, ECT experiments were conducted on CFRP specimens with various manufacturing flaws using the Eddyfi Reddy eddy current array (ECA) system.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
涡流无损评价CFRP复合材料制造缺陷和操作损伤的模拟与实验方法
碳纤维增强聚合物(CFRP)复合材料结构的制造过程中会引入许多特征缺陷和缺陷,如纤维取向错误、纤维波纹和起皱等。因此,在开发的早期阶段检测这些缺陷的存在变得越来越重要。涡流检测(ECT)是一种无损检测技术,已被证明在金属结构损伤检测中是非常有效的。然而,复合材料结构的无损检测主要依靠其他方法,如超声检测(UT)和x射线等,而对ECT的依赖较少。在本文中,作者通过模拟和实验,探讨了在CFRP复合材料NDI中使用ECT的可能性。这项研究是基于这样一个事实,即由于碳纤维的固有导电性,CFRP显示出一些低水平的导电性。这种低导电性可能允许涡流通道在CFRP复合材料中产生涡流,可用于无损损伤检测。还处理了描述我们的高频ECT方法的发明公开。首先,采用多物理场有限元模拟方法对CFRP复合材料的各种制造缺陷和操作损伤(如纤维取向偏差、波纹、起皱等)进行了模拟检测。随后,利用Eddyfi Reddy涡流阵列(ECA)系统对具有各种制造缺陷的CFRP试件进行电刺激实验。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
3.80
自引率
9.10%
发文量
25
期刊最新文献
Enhancement of Contact Acoustic Nonlinearity Effect in a Concrete Beam using Ambient Vibrations Identification of spalling fault size of ball bearing based on modified energy value Deep Learning based Time-Series Classification for Robotic Inspection of Pipe Condition using Non-Contact Ultrasonic Testing AI-enabled crack-length estimation from acoustic emission signal signatures Longitudinal wave propagation in an elastic cylinder embedded in a viscoelastic fluid
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1