Simultaneous Determination of Methylphenidate, Amphetamine and their Metabolites in Urine using Direct Injection Liquid Chromatography-Tandem Mass Spectrometry

IF 0.4 Q4 SPECTROSCOPY Mass Spectrometry Letters Pub Date : 2014-12-30 DOI:10.5478/MSL.2014.5.4.104
Woonyong Kwon, Sungill Suh, M. In, Jin Young Kim
{"title":"Simultaneous Determination of Methylphenidate, Amphetamine and their Metabolites in Urine using Direct Injection Liquid Chromatography-Tandem Mass Spectrometry","authors":"Woonyong Kwon, Sungill Suh, M. In, Jin Young Kim","doi":"10.5478/MSL.2014.5.4.104","DOIUrl":null,"url":null,"abstract":"Nonmedical use of prescription stimulants such as methylphenidate (MPH) and amphetamine (AP) by normal per- sons has been increased to improve cognitive functions. Due to high potential for their abuse, reliable analytical methods were required to detect these prescription stimulants in biological samples. A direct injection liquid chromatography-tandem mass spectrometric (LC-MS/MS) method was developed and implemented for simultaneous determination of MPH, AP and their metabolites ritalinic acid (RA) and 4-hydroxyamphetamine (HAP) in human urine. Urine sample was centrifuged and the upper layer (100 µL) was mixed with 800 µL of distilled water and 100 µL of internal standards (0.2 µg/mL in methanol). The mixture was then directly injected into the LC-MS/MS system. The mobile phase was composed of 0.2% formic acid in distilled water (A) and acetonitrile (B). Chromatographic separation was performed by using a Capcell Pak MG-II C18 (150 mm × 2.0 mm i.d., 5 µm, Shiseido) column and all analytes were eluted within 5 min. Linear least-squares regression with a 1/x weighting factor was used to generate a calibration curve and the assay was linear from 20 to 1500 ng/mL (HAP), 40-3000 ng/mL (AP and RA) and 2-150 ng/mL (MPH). The intra- and inter-day precisions were within 16.4%. The intra- and inter-day accuracies ranged from -15.6% to 10.8%. The limits of detection for all the analytes were less than 4.7 ng/mL. The suitability of the method was examined by analyzing urine samples from drug abusers.","PeriodicalId":18238,"journal":{"name":"Mass Spectrometry Letters","volume":null,"pages":null},"PeriodicalIF":0.4000,"publicationDate":"2014-12-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Mass Spectrometry Letters","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5478/MSL.2014.5.4.104","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"SPECTROSCOPY","Score":null,"Total":0}
引用次数: 1

Abstract

Nonmedical use of prescription stimulants such as methylphenidate (MPH) and amphetamine (AP) by normal per- sons has been increased to improve cognitive functions. Due to high potential for their abuse, reliable analytical methods were required to detect these prescription stimulants in biological samples. A direct injection liquid chromatography-tandem mass spectrometric (LC-MS/MS) method was developed and implemented for simultaneous determination of MPH, AP and their metabolites ritalinic acid (RA) and 4-hydroxyamphetamine (HAP) in human urine. Urine sample was centrifuged and the upper layer (100 µL) was mixed with 800 µL of distilled water and 100 µL of internal standards (0.2 µg/mL in methanol). The mixture was then directly injected into the LC-MS/MS system. The mobile phase was composed of 0.2% formic acid in distilled water (A) and acetonitrile (B). Chromatographic separation was performed by using a Capcell Pak MG-II C18 (150 mm × 2.0 mm i.d., 5 µm, Shiseido) column and all analytes were eluted within 5 min. Linear least-squares regression with a 1/x weighting factor was used to generate a calibration curve and the assay was linear from 20 to 1500 ng/mL (HAP), 40-3000 ng/mL (AP and RA) and 2-150 ng/mL (MPH). The intra- and inter-day precisions were within 16.4%. The intra- and inter-day accuracies ranged from -15.6% to 10.8%. The limits of detection for all the analytes were less than 4.7 ng/mL. The suitability of the method was examined by analyzing urine samples from drug abusers.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
直接注射液相色谱-串联质谱法同时测定尿中哌甲酯、安非他明及其代谢物
正常人非医疗使用处方兴奋剂,如哌甲酯(MPH)和安非他明(AP),以改善认知功能。由于其滥用的可能性很大,因此需要可靠的分析方法来检测生物样品中的这些处方兴奋剂。建立了直接进样液相色谱-串联质谱(LC-MS/MS)同时测定人尿中MPH、AP及其代谢物利他酸(RA)和4-羟安非他明(HAP)的方法。尿样离心后,上层(100µL)与800µL蒸馏水和100µL内标(0.2µg/mL甲醇)混合。然后将混合物直接注入LC-MS/MS系统。流动相组成的0.2%甲酸在蒸馏水(A)和乙腈(B)。色谱分离是由使用Capcell Pak MG-II C18(150毫米×2.0毫米身份证。5µm,资生堂)列和所有分析物中筛选了5分钟。线性最小二乘回归与1 / x权重因子用于生成校准曲线,分析线性从20到1500 ng / mL (HAP), 40 - 3000 ng / mL(美联社和RA)和2 - 150 ng / mL(英里/小时)。日内、日间精度均在16.4%以内。日内和日间的准确度在-15.6%至10.8%之间。所有分析物的检出限均小于4.7 ng/mL。通过对吸毒者尿样的分析,检验了该方法的适用性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
0.90
自引率
20.00%
发文量
0
审稿时长
6 weeks
期刊最新文献
Estimation of Phosphorus Concentration in Silicon Thin Film on Glass Using ToF-SIMS Statistical Characterization of the Multi-Charged Fragment Ions in the CID and HCD Spectrum Screening of Nitrosamine Impurities in Sartan Pharmaceuticals by GC-MS/MS Effect of Ginsenoside Rc on the Pharmacokinetics of Mycophenolic Acid, a UGT1A9 Substrate, and its Glucuronide Metabolite in Rats A Study on the Reduction of Inorganic Arsenic in Hijiki and Rice Using the Various Pretreatments and Inductively Coupled Plasma Mass Spectrometry
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1