Study of Effect of Straight Pipe Length on Ultrasonic Flowmeter Measurement during Typical Baffle Interference

Min Wei, Zhu Rui
{"title":"Study of Effect of Straight Pipe Length on Ultrasonic Flowmeter Measurement during Typical Baffle Interference","authors":"Min Wei, Zhu Rui","doi":"10.21014/tc9-2022.026","DOIUrl":null,"url":null,"abstract":": On the current domestic market, a variety of ultrasonic flowmeters, including those with four (sound) channels, six channels, and eight channels, either through-beam and retro-reflective in channel arrangement, are all claimed to be extremely adaptable to baffle interference and have shorter straight pipes than required by the national standard. To observe and study the tolerance of these gas ultrasonic flowmeters to typical baffle interference and the requirements on the length of the front straight pipe segment, our technical team, according to the process installation requirements of GB/T18604-2014 measurement of natural gas flow by gas ultrasonic flow meters, as well as the AGA NO.9 -2017 report, use the turbine working standard combination system as a flow measurement standard device to test the real flow of natural gas for representative DN100 gas ultrasonic flowmeters with A, B, C, and D channels and different arrangements. Testing process: First, basic data were obtained by testing under ideal pipeline conditions, and then a flow regulator is installed under the interference conditions of typical flow blocking parts (space elbow and manifold are located 30D, 20D and 15D upstream of ultrasonic flowmeter), and see whether the main technical indicators can meet the requirements of trade handover. The technical team of the author designed the test of the effect of different process installation conditions on the measurement accuracy of the gas ultrasonic flowmeter and put forward their own views on the basis of analyzing the test data.","PeriodicalId":62400,"journal":{"name":"流量控制、测量及可视化(英文)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"流量控制、测量及可视化(英文)","FirstCategoryId":"1087","ListUrlMain":"https://doi.org/10.21014/tc9-2022.026","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

: On the current domestic market, a variety of ultrasonic flowmeters, including those with four (sound) channels, six channels, and eight channels, either through-beam and retro-reflective in channel arrangement, are all claimed to be extremely adaptable to baffle interference and have shorter straight pipes than required by the national standard. To observe and study the tolerance of these gas ultrasonic flowmeters to typical baffle interference and the requirements on the length of the front straight pipe segment, our technical team, according to the process installation requirements of GB/T18604-2014 measurement of natural gas flow by gas ultrasonic flow meters, as well as the AGA NO.9 -2017 report, use the turbine working standard combination system as a flow measurement standard device to test the real flow of natural gas for representative DN100 gas ultrasonic flowmeters with A, B, C, and D channels and different arrangements. Testing process: First, basic data were obtained by testing under ideal pipeline conditions, and then a flow regulator is installed under the interference conditions of typical flow blocking parts (space elbow and manifold are located 30D, 20D and 15D upstream of ultrasonic flowmeter), and see whether the main technical indicators can meet the requirements of trade handover. The technical team of the author designed the test of the effect of different process installation conditions on the measurement accuracy of the gas ultrasonic flowmeter and put forward their own views on the basis of analyzing the test data.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
典型挡板干扰下直管长度对超声波流量计测量的影响研究
在目前国内市场上,各种超声波流量计,包括四(声)通道、六通道、八通道,无论是通束式还是反反射式,都声称对挡板干扰具有极强的适应性,直管比国标要求的要短。为了观察和研究这些气体超声波流量计对典型挡板干扰的公差和对前直管段长度的要求,我们的技术团队根据GB/T18604-2014气体超声波流量计测量天然气流量的工艺安装要求,以及AGA NO.9 -2017报告,采用涡轮工作标准组合系统作为流量测量标准装置,对具有代表性的DN100型a、B、C、D通道不同布置的气体超声波流量计进行天然气真实流量的测试。测试流程:首先在理想管道条件下测试获得基础数据,然后在典型流阻部件(空间弯头和歧管分别位于超声波流量计上游30D、20D和15D)的干扰条件下安装流量调节器,看主要技术指标是否能满足行业交接要求。笔者技术团队设计了不同工艺安装条件对气体超声波流量计测量精度影响的试验,并在分析试验数据的基础上提出了自己的看法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
86
期刊最新文献
Investigation of the Correction Factor for Ultrasonic Flow Meters Performance evaluation test of Coriolis flow meters for hydrogen metering at high pressure Establishment of Micro Liquid Flow facility at NIM Traceability of the Primary Nano-flow Measurement System: Measuring the Local Inner Diameter of a Glass Capillary Laboratory and Field Validation of a New Coriolis Metering Concept for Better Measurement Uncertainty, Reliability and Process Insight
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1