{"title":"Invited Product Profile: The Mitra Microsampling Device","authors":"E. Dameron","doi":"10.1097/POC.0000000000000181","DOIUrl":null,"url":null,"abstract":"B lood sampling has been an essential diagnostic tool for many years.Up to 70%of allmedical decisions are guided by diagnostic test results that include blood sample evaluations. Although traditional blood sampling techniques are still necessary, they are not always practical. For example, in remote areas that are a great distance frommedical facilities, access to sampling facilities may be limited. Bloodmicrosampling is a simplifiedmethod of blood sampling that even allows participants to draw their own specimens and mail them to the laboratory for analysis. Microsampling is a procedure for capturing and analyzing minute samples of blood for analysis. The samples collect 10 to 20 μL of blood volume. A conventional sample drawn by venipuncture may consist of sample volumes of up to 10mL, as much as 500 to 1000 times the size of microsamples. The sampling event requires a simple prick of the finger, allowing a drop of blood to rise to the skin surface. Using a device such as this one, the samples are captured in the absorbent tip of the collection devices. The samples are then folded into the attached protective case and can be mailed without refrigeration or special handling to the laboratory (Fig. 1).","PeriodicalId":20262,"journal":{"name":"Point of Care: The Journal of Near-Patient Testing & Technology","volume":"18 1","pages":"26–32"},"PeriodicalIF":0.0000,"publicationDate":"2019-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Point of Care: The Journal of Near-Patient Testing & Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1097/POC.0000000000000181","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

B lood sampling has been an essential diagnostic tool for many years.Up to 70%of allmedical decisions are guided by diagnostic test results that include blood sample evaluations. Although traditional blood sampling techniques are still necessary, they are not always practical. For example, in remote areas that are a great distance frommedical facilities, access to sampling facilities may be limited. Bloodmicrosampling is a simplifiedmethod of blood sampling that even allows participants to draw their own specimens and mail them to the laboratory for analysis. Microsampling is a procedure for capturing and analyzing minute samples of blood for analysis. The samples collect 10 to 20 μL of blood volume. A conventional sample drawn by venipuncture may consist of sample volumes of up to 10mL, as much as 500 to 1000 times the size of microsamples. The sampling event requires a simple prick of the finger, allowing a drop of blood to rise to the skin surface. Using a device such as this one, the samples are captured in the absorbent tip of the collection devices. The samples are then folded into the attached protective case and can be mailed without refrigeration or special handling to the laboratory (Fig. 1).
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
邀请产品简介:Mitra微采样设备
B血取样多年来一直是一种重要的诊断工具。多达70%的医疗决策是由包括血液样本评估在内的诊断测试结果指导的。虽然传统的血液采样技术仍然是必要的,但它们并不总是实用的。例如,在远离医疗设施的偏远地区,取样设施的使用可能受到限制。血液微采样是一种简化的血液采样方法,甚至允许参与者自己抽取样本并将其邮寄到实验室进行分析。微采样是一种捕获和分析用于分析的微小血液样本的程序。样品血容量为10 ~ 20 μL。通过静脉穿刺抽取的常规样品可能包含高达10mL的样品体积,相当于微样品大小的500至1000倍。采样过程只需要简单地刺破手指,让一滴血上升到皮肤表面。使用这样的设备,样品被捕获在收集设备的吸收尖端。然后将样品折叠到附带的保护盒中,无需冷藏或特殊处理即可邮寄到实验室(图1)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
A Comparison of International Normalized Ratio Results by Point-of-Care Device and Clinical Laboratory Analyzers in a Vascular Surgery Department Point-of-Care Testing in Hypercoagulable Conditions Managed With Warfarin Critical Care Nurses' Views and Experiences of Preanalytical Factors Influencing Point-of-Care Testing Rapid Assessment of Coagulation at the Point of Care With the Hemochron Signature Elite System Invited Product Profile: Detecting Antibodies for Lyme Disease at the Point of Care
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1