Dosimetric Parameters Comparison of Four-Field and Field-in-Field Radiotherapy Planning in Treatment of Prostate Cancer

Q3 Health Professions Frontiers in Biomedical Technologies Pub Date : 2022-08-30 DOI:10.18502/fbt.v9i4.10427
Gholamreza Fallah Mohammadi, F. Falahati, Fatemeh Zakeri, Seyyed Mohammad Motevalli, Ehsan Mihandoost
{"title":"Dosimetric Parameters Comparison of Four-Field and Field-in-Field Radiotherapy Planning in Treatment of Prostate Cancer","authors":"Gholamreza Fallah Mohammadi, F. Falahati, Fatemeh Zakeri, Seyyed Mohammad Motevalli, Ehsan Mihandoost","doi":"10.18502/fbt.v9i4.10427","DOIUrl":null,"url":null,"abstract":"Purpose: Prostate cancer is one of the most common malignant cancers. Several radiotherapy planning methods have been suggested for the treatment of prostate cancer. In this study, four-field, and Field-In-Field (FIF) planning methods were compared based on dosimetric parameters. \nMaterials and Methods: In the radiotherapy Treatment Planning System (TPS) for 10 patients who were treated with the common four-field method, the planning was also performed by the FIF method. Dosimetric parameters were measured for Planning Target Volume (PTV), rectum, and bladder. These parameters included maximum dose, minimum dose, mean dose, V15%, V25%, V30%, and V35%, as well as Homogeneity Index (HI) and Conformity Index (CI). Two treatment planning methods based on dosimetric parameters were compared using paired t-test. \nResults: Maximum, minimum and mean dose in PTV, rectum, and bladder were significantly different for the two techniques.  There was no significant difference between the two planning techniques in dosimetric parameters of V15%, V25%, V30%, and V35% for rectum and bladder. The FIF technique delivers more doses to the tumor. HI was better in the FIF method than in the four-field method, but CI was not significantly different. In both techniques, the rectum and bladder did not receive doses above 60 Gy. \nConclusion: In the treatment of prostate cancer in both Four-field and FIF planning methods, the dose to the rectum and bladder is less than the tolerance dose. FIF technique is recommended to better control the tumor. Based on dosimetric parameters, no significant findings were obtained that prove the superiority of FIF over the four-field technique in the treatment of prostate cancer.","PeriodicalId":34203,"journal":{"name":"Frontiers in Biomedical Technologies","volume":"3 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2022-08-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Frontiers in Biomedical Technologies","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.18502/fbt.v9i4.10427","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Health Professions","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: Prostate cancer is one of the most common malignant cancers. Several radiotherapy planning methods have been suggested for the treatment of prostate cancer. In this study, four-field, and Field-In-Field (FIF) planning methods were compared based on dosimetric parameters. Materials and Methods: In the radiotherapy Treatment Planning System (TPS) for 10 patients who were treated with the common four-field method, the planning was also performed by the FIF method. Dosimetric parameters were measured for Planning Target Volume (PTV), rectum, and bladder. These parameters included maximum dose, minimum dose, mean dose, V15%, V25%, V30%, and V35%, as well as Homogeneity Index (HI) and Conformity Index (CI). Two treatment planning methods based on dosimetric parameters were compared using paired t-test. Results: Maximum, minimum and mean dose in PTV, rectum, and bladder were significantly different for the two techniques.  There was no significant difference between the two planning techniques in dosimetric parameters of V15%, V25%, V30%, and V35% for rectum and bladder. The FIF technique delivers more doses to the tumor. HI was better in the FIF method than in the four-field method, but CI was not significantly different. In both techniques, the rectum and bladder did not receive doses above 60 Gy. Conclusion: In the treatment of prostate cancer in both Four-field and FIF planning methods, the dose to the rectum and bladder is less than the tolerance dose. FIF technique is recommended to better control the tumor. Based on dosimetric parameters, no significant findings were obtained that prove the superiority of FIF over the four-field technique in the treatment of prostate cancer.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
前列腺癌四场与场内放疗计划剂量学参数比较
目的:前列腺癌是最常见的恶性肿瘤之一。几种放疗计划方法已被建议用于治疗前列腺癌。在本研究中,比较了基于剂量学参数的四场规划和场中规划(FIF)方法。材料与方法:采用常规四场法治疗的10例患者的放疗计划系统(TPS)也采用FIF法进行计划。测量计划靶体积(PTV)、直肠和膀胱的剂量学参数。这些参数包括最大剂量、最小剂量、平均剂量、V15%、V25%、V30%和V35%,以及均匀性指数(HI)和符合性指数(CI)。采用配对t检验比较两种基于剂量学参数的治疗方案。结果:两种方法在PTV、直肠和膀胱的最大、最小和平均剂量有显著差异。两种计划技术在直肠和膀胱V15%、V25%、V30%和V35%的剂量学参数上无显著差异。FIF技术向肿瘤提供更多的剂量。FIF法的HI优于四场法,但CI无显著差异。在这两种技术中,直肠和膀胱接受的剂量都没有超过60戈瑞。结论:四场法和FIF法治疗前列腺癌时,对直肠和膀胱的剂量均小于耐受剂量。建议采用FIF技术更好地控制肿瘤。根据剂量学参数,没有明显的发现证明FIF在治疗前列腺癌方面优于四场技术。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Frontiers in Biomedical Technologies
Frontiers in Biomedical Technologies Health Professions-Medical Laboratory Technology
CiteScore
0.80
自引率
0.00%
发文量
34
审稿时长
12 weeks
期刊最新文献
AI in Nuclear Medical Applications: Challenges and Opportunities Evaluation of Eye-Blinking Dynamics in Human Emotion Recognition Using Weighted Visibility Graph Assessment of SPECT Image Reconstruction in Liver Scanning Using 99mTc/ EDDA/ HYNIC-TOCAssessment of SPECT Image Reconstruction in Liver Scanning Using 99mTc/ EDDA/ HYNIC-TOC Analysis of the Prevalence of Lumbar Annular Tears in Adult Patients Using Magnetic Resonance Imaging Data Grading the Dominant Pathological Indices in Liver Diseases from Pathological Images Using Radiomics Methods
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1