{"title":"Water treeing and condition assessment of high voltage XLPE cables","authors":"S. Hvidsten, H. Faremo, R. Eriksson, Wei Min","doi":"10.1109/ELINSL.2002.995893","DOIUrl":null,"url":null,"abstract":"The results show that the degree of water treeing in HV XLPE cables (36 kV and above) is strongly dependent upon the cable design and the service (system) voltage. The water trees are typically relatively short, but their density is similar to that observed in medium voltage cables with similar design. The results from the nondestructive diagnostic testing show that it can be possible to detect water treeing also in old high voltage cables extending diagnostic techniques developed for medium voltage cables.","PeriodicalId":10532,"journal":{"name":"Conference Record of the the 2002 IEEE International Symposium on Electrical Insulation (Cat. No.02CH37316)","volume":"83 1","pages":"112-115"},"PeriodicalIF":0.0000,"publicationDate":"2002-04-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Conference Record of the the 2002 IEEE International Symposium on Electrical Insulation (Cat. No.02CH37316)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ELINSL.2002.995893","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

Abstract

The results show that the degree of water treeing in HV XLPE cables (36 kV and above) is strongly dependent upon the cable design and the service (system) voltage. The water trees are typically relatively short, but their density is similar to that observed in medium voltage cables with similar design. The results from the nondestructive diagnostic testing show that it can be possible to detect water treeing also in old high voltage cables extending diagnostic techniques developed for medium voltage cables.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
高压交联聚乙烯电缆的水树及状态评定
结果表明,高压交联聚乙烯电缆(36kv及以上)的疏水程度与电缆设计和供电(系统)电压有很大关系。水树通常相对较短,但它们的密度与类似设计的中压电缆中观察到的密度相似。无损诊断试验结果表明,在中压电缆无损诊断技术的基础上,也可以对老旧高压电缆进行水树检测。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
After-installation test of HV extruded cable insulation Experimental investigation into the thermal-ageing of Kraft paper and mineral insulating oil Enhanced online PD evaluation on power transformers using wavelet techniques and frequency rejection filter for noise suppression On-line PD detection, requirements for practical use PD site location in distribution power cables
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1