Efficacy and Safety of OTX-101, a Novel Nanomicellar Formulation of Cyclosporine A, for the Treatment of Keratoconjunctivitis Sicca: Pooled Analysis of a Phase 2b/3 and Phase 3 Study.
J. Sheppard, Shane R. Kannarr, J. Luchs, R. Malhotra, A. Justice, A. Ogundele, Charles Darby, J. Bacharach
{"title":"Efficacy and Safety of OTX-101, a Novel Nanomicellar Formulation of Cyclosporine A, for the Treatment of Keratoconjunctivitis Sicca: Pooled Analysis of a Phase 2b/3 and Phase 3 Study.","authors":"J. Sheppard, Shane R. Kannarr, J. Luchs, R. Malhotra, A. Justice, A. Ogundele, Charles Darby, J. Bacharach","doi":"10.1097/ICL.0000000000000636","DOIUrl":null,"url":null,"abstract":"BACKGROUND OTX-101 (CEQUA™) is approved in the United States for treatment of keratoconjunctivitis sicca (KCS). This pooled analysis of 2 studies (phase 2b/3 and phase 3) evaluates the efficacy and safety of OTX-101 0.09% in the intent-to-treat (ITT) population and the subgroup of patients with a baseline Schirmer score less than 10 mm. METHODS In these randomized, multicenter, double-masked, vehicle-controlled studies, patients received 1 drop of either OTX-101 or vehicle in both eyes twice daily. A Schirmer's test was performed at baseline and day 84/early discontinuation. Symptom Assessment iN Dry Eye (SANDE) scores and adverse events were monitored at each visit. RESULTS The pooled analysis included 523 and 525 patients randomized to OTX-101 0.09% and vehicle, respectively. In the ITT population, 16.6% of eyes receiving OTX-101 and 9.0% of eyes receiving vehicle showed a day 84 increase in Schirmer score ≥10 mm from baseline (P<0.0001). In the subgroup with Schirmer score less than 10 mm at baseline, 18.7% and 10.2% of eyes receiving OTX-101 and vehicle, respectively, exhibited this outcome (P=0.0001). The mean (SD) percent change from baseline in global SANDE scores on day 84 in the ITT population was -29.0% (39.0%) and -30.4% (39.5%) for OTX-101 and vehicle groups, respectively. In the subgroup, the mean (SD) percent change was -27.3% (39.7%) and -31.4% (38.3%) for OTX-101 and vehicle groups, respectively. Adverse events were mostly mild to moderate. CONCLUSIONS OTX-101 improved tear production compared with vehicle. Both OTX-101 and vehicle showed improved SANDE scores over baseline. OTX-101 was well tolerated in patients with KCS.","PeriodicalId":12216,"journal":{"name":"Eye & Contact Lens: Science & Clinical Practice","volume":"123 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2019-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"16","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Eye & Contact Lens: Science & Clinical Practice","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1097/ICL.0000000000000636","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 16
Abstract
BACKGROUND OTX-101 (CEQUA™) is approved in the United States for treatment of keratoconjunctivitis sicca (KCS). This pooled analysis of 2 studies (phase 2b/3 and phase 3) evaluates the efficacy and safety of OTX-101 0.09% in the intent-to-treat (ITT) population and the subgroup of patients with a baseline Schirmer score less than 10 mm. METHODS In these randomized, multicenter, double-masked, vehicle-controlled studies, patients received 1 drop of either OTX-101 or vehicle in both eyes twice daily. A Schirmer's test was performed at baseline and day 84/early discontinuation. Symptom Assessment iN Dry Eye (SANDE) scores and adverse events were monitored at each visit. RESULTS The pooled analysis included 523 and 525 patients randomized to OTX-101 0.09% and vehicle, respectively. In the ITT population, 16.6% of eyes receiving OTX-101 and 9.0% of eyes receiving vehicle showed a day 84 increase in Schirmer score ≥10 mm from baseline (P<0.0001). In the subgroup with Schirmer score less than 10 mm at baseline, 18.7% and 10.2% of eyes receiving OTX-101 and vehicle, respectively, exhibited this outcome (P=0.0001). The mean (SD) percent change from baseline in global SANDE scores on day 84 in the ITT population was -29.0% (39.0%) and -30.4% (39.5%) for OTX-101 and vehicle groups, respectively. In the subgroup, the mean (SD) percent change was -27.3% (39.7%) and -31.4% (38.3%) for OTX-101 and vehicle groups, respectively. Adverse events were mostly mild to moderate. CONCLUSIONS OTX-101 improved tear production compared with vehicle. Both OTX-101 and vehicle showed improved SANDE scores over baseline. OTX-101 was well tolerated in patients with KCS.