{"title":"Development of near-fault loading protocols for first-story steel columns in dual systems with BRBs","authors":"Yu-Fang Liu, C. Chou, GuanRu Peng, Kuan-Ju Chen","doi":"10.1080/02533839.2022.2141343","DOIUrl":null,"url":null,"abstract":"ABSTRACT The AISC 341–16 (2016) has loading protocols for beam-to-column moment connections and buckling-restrained braces, but it does not have a loading protocol for columns. Because a first-story column base is expected to form a plastic hinge in a building, a loading protocol for first-story columns in a dual system that comprises moment-resisting frames and buckling-restrained braced frames under varied axial force and lateral drift is required. Moreover, the symmetric cyclic loading protocols of AISC 341 do not include the effect of near-fault earthquakes, which is common in Taiwan. Therefore, the effect of near-fault earthquakes on first-story columns must be considered during the development of a loading protocol for dual systems. In the present study, four dual systems (representing 3-story, 7-story, 15-story, and 25-story frames) are subjected to 11 near-fault earthquake motions, used for developing near-fault loading protocols of first-story columns for the lateral drift and axial load responses.","PeriodicalId":17313,"journal":{"name":"Journal of the Chinese Institute of Engineers","volume":"55 1","pages":"39 - 52"},"PeriodicalIF":1.0000,"publicationDate":"2022-11-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of the Chinese Institute of Engineers","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1080/02533839.2022.2141343","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 1
Abstract
ABSTRACT The AISC 341–16 (2016) has loading protocols for beam-to-column moment connections and buckling-restrained braces, but it does not have a loading protocol for columns. Because a first-story column base is expected to form a plastic hinge in a building, a loading protocol for first-story columns in a dual system that comprises moment-resisting frames and buckling-restrained braced frames under varied axial force and lateral drift is required. Moreover, the symmetric cyclic loading protocols of AISC 341 do not include the effect of near-fault earthquakes, which is common in Taiwan. Therefore, the effect of near-fault earthquakes on first-story columns must be considered during the development of a loading protocol for dual systems. In the present study, four dual systems (representing 3-story, 7-story, 15-story, and 25-story frames) are subjected to 11 near-fault earthquake motions, used for developing near-fault loading protocols of first-story columns for the lateral drift and axial load responses.
期刊介绍:
Encompassing a wide range of engineering disciplines and industrial applications, JCIE includes the following topics:
1.Chemical engineering
2.Civil engineering
3.Computer engineering
4.Electrical engineering
5.Electronics
6.Mechanical engineering
and fields related to the above.