Use of High Definition Multileaf Colimator for the Treatment of Trigeminal Neuralgia

Eduardo Cabello Murillo, Ana Milanés Gaillet, Gustavo Pozo Rodriguez, Ángel Gaitán Simón, P. Hernández, Marta Rodríguez, A. F. Sanchez, R. D. Fuentes
{"title":"Use of High Definition Multileaf Colimator for the Treatment of Trigeminal Neuralgia","authors":"Eduardo Cabello Murillo, Ana Milanés Gaillet, Gustavo Pozo Rodriguez, Ángel Gaitán Simón, P. Hernández, Marta Rodríguez, A. F. Sanchez, R. D. Fuentes","doi":"10.4236/ijmpcero.2022.113013","DOIUrl":null,"url":null,"abstract":"In the present work, a treatment technique for trigeminal neuralgia (TN) using LINAC radiosurgery is shown. The technique is based on the optimization of ten static arcs in such a way as to minimize the overlapping of the treatment fields with the brainstem. We will call this technique brainstem-optimized (BO). The results are compared with another technique described in the litera-ture known as a virtual cone (VC). The comparison of dosimetry results that have been carried out essentially shows that the doses in the brainstem V12Gy-brainstem, D0.5cm 3 -brainstem and D0.035 cm 3 -brainstem are lower in the BO versus VC technique, and with the parameters V50% (whole brain) and V12Gy-cerebrum higher in BO versus VC. Our goal is to keep the dose to the brainstem as low as possible and, if possible, at most between 12 Gy and 15 Gy. The BO technique meets our purposes and is considered clinically acceptable at our institution.","PeriodicalId":14028,"journal":{"name":"International Journal of Medical Physics, Clinical Engineering and Radiation Oncology","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2022-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Medical Physics, Clinical Engineering and Radiation Oncology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4236/ijmpcero.2022.113013","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

In the present work, a treatment technique for trigeminal neuralgia (TN) using LINAC radiosurgery is shown. The technique is based on the optimization of ten static arcs in such a way as to minimize the overlapping of the treatment fields with the brainstem. We will call this technique brainstem-optimized (BO). The results are compared with another technique described in the litera-ture known as a virtual cone (VC). The comparison of dosimetry results that have been carried out essentially shows that the doses in the brainstem V12Gy-brainstem, D0.5cm 3 -brainstem and D0.035 cm 3 -brainstem are lower in the BO versus VC technique, and with the parameters V50% (whole brain) and V12Gy-cerebrum higher in BO versus VC. Our goal is to keep the dose to the brainstem as low as possible and, if possible, at most between 12 Gy and 15 Gy. The BO technique meets our purposes and is considered clinically acceptable at our institution.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
应用高清晰度多叶准直仪治疗三叉神经痛
在本工作中,展示了一种使用LINAC放射外科治疗三叉神经痛(TN)的技术。该技术基于十个静态弧线的优化,这样可以最大限度地减少治疗场与脑干的重叠。我们将这种技术称为脑干优化(BO)。结果与文献中描述的另一种称为虚拟锥(VC)的技术进行了比较。已经进行的剂量学结果的比较基本上表明,BO与VC相比,脑干v12gy -脑干、D0.5cm - 3脑干和D0.035 cm - 3脑干的剂量较低,而BO与VC相比,V50%(全脑)和v12gy -脑的参数较高。我们的目标是使脑干受到的辐射剂量尽可能低,如果可能,最多在12戈瑞到15戈瑞之间。BO技术符合我们的目的,在我们的机构被认为是临床可接受的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Assessment of Monitor Units and Gamma Pass Rate for 6 MV and Flattening Filter Free (FFF) Beams in Volumetric Modulated Arc Therapy (VMAT) The Journey of SRS: An Initial Experience of Starting Sterotactic Radiosurgery Facility at Purbanchal Cancer Hospital—First in Nepal Hereditary Multiple Exostoses (HME) with Peroneal Nerve Compresion: A Case Report Dosimetric Study of the Effect of Calypso-Compatible Couch Top for Spine Stereotactic Body Radiation Therapy Radiation-Associated Cardiotoxicity during Breast Cancer Treatment with Ionizing Radiation
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1