{"title":"Machine Learning Improves the Detection of Misplaced V1 and V2 Electrodes During 12-Lead Electrocardiogram Acquisition","authors":"K. Rjoob, R. Bond, D. Finlay, V. Mcgilligan, Stephen Leslie, Aleeha Iftikhar, D. Guldenring, A. Rababah, C. Knoery, A. Peace","doi":"10.23919/CinC49843.2019.9005828","DOIUrl":null,"url":null,"abstract":"Electrode misplacement during 12-lead Electrocardiogram (ECG) acquisition can cause false ECG diagnosis and subsequent incorrect clinical treatment. A common misplacement error is the superior placement of V1 and V2 electrodes. The aim of the current research was to detect lead V1 and V2 misplacement using machine learning to enhance ECG data quality to improve clinical decision making. In this particular study, we reasonably assume that V1 and V2 are concurrently superiorly misplaced together. ECGs for 450 patients were extracted from body surface potential maps. Sixteen features were extracted including: morphological, statistical and time-frequency features. Two feature selection approaches (filter method and wrapper method) were applied to find an optimal set of features that provide a high accuracy. To ensure accuracy, six classifiers were applied including: fine tree, coarse tree, bagged tree, Linear Support Vector Machine (LSVM), Quadratic Support Vector Machine (QSVM) and logistic regression. The accuracy of V1 and V2 misplacement detection was 94.3% in the first ICS, 92.7% in the second ICS and 70% in third ICS respectively. Bagged tree was the best classifier in the first, second and third ICS to detect V1 and V2 misplacement.","PeriodicalId":6697,"journal":{"name":"2019 Computing in Cardiology (CinC)","volume":"39 1","pages":"1-4"},"PeriodicalIF":0.0000,"publicationDate":"2019-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 Computing in Cardiology (CinC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.23919/CinC49843.2019.9005828","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Electrode misplacement during 12-lead Electrocardiogram (ECG) acquisition can cause false ECG diagnosis and subsequent incorrect clinical treatment. A common misplacement error is the superior placement of V1 and V2 electrodes. The aim of the current research was to detect lead V1 and V2 misplacement using machine learning to enhance ECG data quality to improve clinical decision making. In this particular study, we reasonably assume that V1 and V2 are concurrently superiorly misplaced together. ECGs for 450 patients were extracted from body surface potential maps. Sixteen features were extracted including: morphological, statistical and time-frequency features. Two feature selection approaches (filter method and wrapper method) were applied to find an optimal set of features that provide a high accuracy. To ensure accuracy, six classifiers were applied including: fine tree, coarse tree, bagged tree, Linear Support Vector Machine (LSVM), Quadratic Support Vector Machine (QSVM) and logistic regression. The accuracy of V1 and V2 misplacement detection was 94.3% in the first ICS, 92.7% in the second ICS and 70% in third ICS respectively. Bagged tree was the best classifier in the first, second and third ICS to detect V1 and V2 misplacement.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
机器学习改进了12导联心电图采集过程中V1和V2电极错位的检测
在12导联心电图采集过程中,电极错位会导致错误的心电图诊断和随后的错误临床治疗。常见的放置错误是V1和V2电极的优越放置。当前研究的目的是利用机器学习检测导联V1和V2错位,以提高ECG数据质量,从而改善临床决策。在这个特殊的研究中,我们合理地假设V1和V2同时优越地错位在一起。从体表电位图中提取450例患者的心电图。提取了16个特征,包括形态特征、统计特征和时频特征。采用两种特征选择方法(滤波法和包装法)来寻找提供高精度的最优特征集。为了保证分类精度,采用了细树、粗树、袋装树、线性支持向量机(LSVM)、二次支持向量机(QSVM)和逻辑回归六种分类器。第一次、第二次、第三次检测V1、V2错位的准确率分别为94.3%、92.7%和70%。套袋树是第一、第二和第三种ICS中检测V1和V2错位的最佳分类器。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
An Automated Approach Based on a Convolutional Neural Network for Left Atrium Segmentation From Late Gadolinium Enhanced Magnetic Resonance Imaging Multiobjective Optimization Approach to Localization of Ectopic Beats by Single Dipole: Case Study Sepsis Prediction in Intensive Care Unit Using Ensemble of XGboost Models A Comparative Analysis of HMM and CRF for Early Prediction of Sepsis Blocking L-Type Calcium Current Reduces Vulnerability to Re-Entry in Human iPSC-Derived Cardiomyocytes Tissue
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1