{"title":"Development of calculation method for melting amount mass of contact wire caused by melting and evaporation of molten metal bridge and arc generation","authors":"Honoka Morishita, Yoshifumi Maeda, Zhenwei Ren, Yusuke Nemoto, Takamasa Hayasaka, Toru Iwao","doi":"10.1002/eej.23403","DOIUrl":null,"url":null,"abstract":"<p>As the mileage of the electric railway increases, the unevenness of the contact wire may separate the contact wire and the contact strip. Simultaneously, a disconnection arc discharge is generated by the molten metal bridge. This causes the contact wire to melt and evaporate causing it to break. A few studies have conducted experiments to prevent the contact wire from disconnecting. Based on the results thus obtained, they presented their hypotheses considering conditions sch as the current and time required for melting and evaporation of molten metal bridge and arc generation. In this study, a calculation method for the melting and disconnection phenomenon of the contact wire. Its mass increased when the currents from both sides of the contact wire were taken into consideration. Therefore, we obtained that the convection and radiation play an improtant role for calculation of the melting amount mass of contact wire.</p>","PeriodicalId":50550,"journal":{"name":"Electrical Engineering in Japan","volume":"215 3","pages":""},"PeriodicalIF":0.4000,"publicationDate":"2022-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Electrical Engineering in Japan","FirstCategoryId":"5","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/eej.23403","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 2
Abstract
As the mileage of the electric railway increases, the unevenness of the contact wire may separate the contact wire and the contact strip. Simultaneously, a disconnection arc discharge is generated by the molten metal bridge. This causes the contact wire to melt and evaporate causing it to break. A few studies have conducted experiments to prevent the contact wire from disconnecting. Based on the results thus obtained, they presented their hypotheses considering conditions sch as the current and time required for melting and evaporation of molten metal bridge and arc generation. In this study, a calculation method for the melting and disconnection phenomenon of the contact wire. Its mass increased when the currents from both sides of the contact wire were taken into consideration. Therefore, we obtained that the convection and radiation play an improtant role for calculation of the melting amount mass of contact wire.
期刊介绍:
Electrical Engineering in Japan (EEJ) is an official journal of the Institute of Electrical Engineers of Japan (IEEJ). This authoritative journal is a translation of the Transactions of the Institute of Electrical Engineers of Japan. It publishes 16 issues a year on original research findings in Electrical Engineering with special focus on the science, technology and applications of electric power, such as power generation, transmission and conversion, electric railways (including magnetic levitation devices), motors, switching, power economics.