In situ strength assessment of concrete using recycled aggregates by means of small diameter cores.

S. I. Javadein, R. Madandoust, S. M. Mirhosseini
{"title":"In situ strength assessment of concrete using recycled aggregates by means of small diameter cores.","authors":"S. I. Javadein, R. Madandoust, S. M. Mirhosseini","doi":"10.22075/JRCE.2020.16540.1310","DOIUrl":null,"url":null,"abstract":"By increasing the demolition of old concrete structures and the interest of civil industries to consume cheaper materials, using Recycled Concrete Aggregate (RCA) can cause environmental protection and decrease the construction costs. On the other hand, the high potential of Recycled Aggregate Concrete (RAC) in concrete industry was established by extensive experimental researches were performed to examine the properties of RAC. Like in conventional concrete, core test cut from RAC can be used to assess the in-place concrete compressive strength and sometimes it becomes an important test for monitoring in-situ properties of concrete to taking up retrofitting/strengthening measures. So the core test is often mentioned in most codes for concrete testing. The layout of this study includes four concrete mixes, two concrete grades (20 and 40 MPa), three core diameters (46, 69, and 100 mm), five length-to-diameter (L/D) ratios (1, 1.25, 1.5, 1.75, and 2), two sizes of maximum coarse recycled aggregates (10 and 20 mm), two directions of core drilling which are vertical and horizontal and three ages of the specimen (14, 28 and 90 days). The core test results were compared to cylindrical and cube specimens. Results imply that the core strength of recycled concrete reduces with the increase in aspect ratio, by decreasing the core diameter, increasing the size of coarse aggregates in recycled concrete. By analyzing the results a comparison was made between recycled concrete in this study and conventional concrete in other studies, as well as code instructions.","PeriodicalId":52415,"journal":{"name":"Journal of Rehabilitation in Civil Engineering","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2020-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Rehabilitation in Civil Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.22075/JRCE.2020.16540.1310","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Engineering","Score":null,"Total":0}
引用次数: 0

Abstract

By increasing the demolition of old concrete structures and the interest of civil industries to consume cheaper materials, using Recycled Concrete Aggregate (RCA) can cause environmental protection and decrease the construction costs. On the other hand, the high potential of Recycled Aggregate Concrete (RAC) in concrete industry was established by extensive experimental researches were performed to examine the properties of RAC. Like in conventional concrete, core test cut from RAC can be used to assess the in-place concrete compressive strength and sometimes it becomes an important test for monitoring in-situ properties of concrete to taking up retrofitting/strengthening measures. So the core test is often mentioned in most codes for concrete testing. The layout of this study includes four concrete mixes, two concrete grades (20 and 40 MPa), three core diameters (46, 69, and 100 mm), five length-to-diameter (L/D) ratios (1, 1.25, 1.5, 1.75, and 2), two sizes of maximum coarse recycled aggregates (10 and 20 mm), two directions of core drilling which are vertical and horizontal and three ages of the specimen (14, 28 and 90 days). The core test results were compared to cylindrical and cube specimens. Results imply that the core strength of recycled concrete reduces with the increase in aspect ratio, by decreasing the core diameter, increasing the size of coarse aggregates in recycled concrete. By analyzing the results a comparison was made between recycled concrete in this study and conventional concrete in other studies, as well as code instructions.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
采用小直径芯的再生骨料混凝土的原位强度评估。
通过增加旧混凝土结构的拆除和民用工业对消耗更便宜材料的兴趣,使用再生混凝土骨料(RCA)可以保护环境并降低建筑成本。另一方面,通过对再生骨料混凝土性能的大量试验研究,确立了再生骨料混凝土在混凝土工业中的巨大潜力。与常规混凝土一样,RAC岩心试验可用于评估混凝土的现场抗压强度,有时也成为监测混凝土现场性能以采取改造/加固措施的重要试验手段。因此,核心测试在大多数混凝土测试规范中经常被提及。本研究的布局包括四种混凝土配合比、两种混凝土等级(20和40 MPa)、三种岩心直径(46、69和100 mm)、五种长径比(L/D)(1,1.25、1.5、1.75和2)、两种最大粗再生骨料尺寸(10和20 mm)、两种岩心钻孔方向(垂直和水平)以及三种龄期(14、28和90天)。将岩心试验结果与圆柱形和立方体试件进行了比较。结果表明:随着长径比的增大,再生混凝土芯材强度降低,主要表现为芯材直径的减小,再生混凝土粗集料粒径的增大。通过对研究结果的分析,将本研究的再生混凝土与其他研究的常规混凝土进行了比较,并对规范说明进行了比较。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Journal of Rehabilitation in Civil Engineering
Journal of Rehabilitation in Civil Engineering Engineering-Building and Construction
CiteScore
1.60
自引率
0.00%
发文量
0
审稿时长
12 weeks
期刊最新文献
Damage Sensitive-Stories of RC and Steel Frames under Critical Mainshock-Aftershock Ground Motions Evaluation of Intermediate Reinforced Concrete Moment Frame subjected to Truck collision Damage Detection in Prestressed Concrete Slabs Using Wavelet Analysis of Vibration Responses in the Time Domain Rehabilitation of Corroded Reinforced Concrete Elements by Rebar Replacement Risk assessment and challenges faced in repairs and rehabilitation of dilapidated buildings.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1