Evaluation method of common-mode choke coil used for high speed telecommunications port

T. Hoshino, F. Amemiya, N. Kuwabara
{"title":"Evaluation method of common-mode choke coil used for high speed telecommunications port","authors":"T. Hoshino, F. Amemiya, N. Kuwabara","doi":"10.1109/ISEMC.2005.1513502","DOIUrl":null,"url":null,"abstract":"A method of measuring characteristics of the common-mode choke coil, which is used for a high-speed telecommunications system using UTP cable, is needed to evaluate the performance. We present a new method of measuring the S-parameters of the coil. The two-port F-matrix parameters of the balun were obtained from three-port S-parameters, and the S-parameters of the coil were measured at the unbalance port of the baluns, which was connected to both ends of the coil. The F-matrix parameters of the coil were obtained from the F-matrix parameters of the balun and the measured S-parameters. When two baluns were connected to each other at the balance ports, the S-parameters were measured find compared with the calculated value from the F-matrix parameters of the balun. The results indicated that the difference was within 0.1 dB from 30 MHz to 100 MHz, and within 1 dB from 100 MHz to 300 MHz. The differential mode insertion losses were also measured for five types of the coils. The results indicated that the proposed method obtained a realistic insertion loss value which was not less than 0 dB although the insertion loss measured by the usual method was not a realistic value because it was less than 0 dB up to 100 MHz.","PeriodicalId":6459,"journal":{"name":"2005 International Symposium on Electromagnetic Compatibility, 2005. EMC 2005.","volume":"34 1","pages":"210-215 Vol. 1"},"PeriodicalIF":0.0000,"publicationDate":"2005-10-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2005 International Symposium on Electromagnetic Compatibility, 2005. EMC 2005.","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISEMC.2005.1513502","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

A method of measuring characteristics of the common-mode choke coil, which is used for a high-speed telecommunications system using UTP cable, is needed to evaluate the performance. We present a new method of measuring the S-parameters of the coil. The two-port F-matrix parameters of the balun were obtained from three-port S-parameters, and the S-parameters of the coil were measured at the unbalance port of the baluns, which was connected to both ends of the coil. The F-matrix parameters of the coil were obtained from the F-matrix parameters of the balun and the measured S-parameters. When two baluns were connected to each other at the balance ports, the S-parameters were measured find compared with the calculated value from the F-matrix parameters of the balun. The results indicated that the difference was within 0.1 dB from 30 MHz to 100 MHz, and within 1 dB from 100 MHz to 300 MHz. The differential mode insertion losses were also measured for five types of the coils. The results indicated that the proposed method obtained a realistic insertion loss value which was not less than 0 dB although the insertion loss measured by the usual method was not a realistic value because it was less than 0 dB up to 100 MHz.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
高速通信端口用共模扼流圈评价方法
为了评价高速通信系统中使用的UTP电缆共模扼流圈的性能,需要一种测量共模扼流圈特性的方法。提出了一种测量线圈s参数的新方法。由三端口s参数得到平衡轮的两端口f矩阵参数,并在连接到平衡轮两端的不平衡端口处测量线圈的s参数。线圈的f矩阵参数由平衡器的f矩阵参数和测得的s参数得到。当两个平衡器在平衡端口相互连接时,测量s参数,并与平衡器f矩阵参数的计算值进行比较。结果表明,从30 MHz到100 MHz,差异在0.1 dB以内,从100 MHz到300 MHz,差异在1 dB以内。还测量了五种类型线圈的差模插入损耗。结果表明,该方法获得了不小于0 dB的实际插入损耗值,而通常方法测量的插入损耗值在100 MHz以内小于0 dB而不是实际插入损耗值。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Variability of dual TEM cell shielding effectiveness measurements for vapor grown carbon nanofiber/vinyl ester composites Development of a multiresolution time domain EMI measurement system that fulfills CISPR 16-1 Improved lumped-pi circuit model for bulk current injection probes Matched lossy decoupling termination for power plane noise mitigation Comparison of measured and computed local electric field distributions due to vehicle-mounted antennas using 2D feature selective validation
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1