{"title":"Investigation of partial discharge pulse shapes occurring at interfaces in model joints","authors":"Z. Nadolny, J. Braun, R. Densley","doi":"10.1109/ICSD.1998.709240","DOIUrl":null,"url":null,"abstract":"The understanding of degradation processes in transmission-class cable joints is very important to the reliability of the operating system. Degradation caused by partial discharges (PD) and their associated characteristics were investigated in model \"pre-fabricated\" cable joints. Time to breakdown and PD pulse parameters such as rise time, width, fall time, amplitude and frequency were studied. The paper further describes PD pulse parameters occurring within different part of cable joints, such as within the epoxy casting near the high voltage electrode and along the EPR-epoxy interfaces.","PeriodicalId":13148,"journal":{"name":"ICSD'98. Proceedings of the 1998 IEEE 6th International Conference on Conduction and Breakdown in Solid Dielectrics (Cat. No.98CH36132)","volume":"74 1","pages":"119-122"},"PeriodicalIF":0.0000,"publicationDate":"1998-06-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"15","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ICSD'98. Proceedings of the 1998 IEEE 6th International Conference on Conduction and Breakdown in Solid Dielectrics (Cat. No.98CH36132)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICSD.1998.709240","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 15

Abstract

The understanding of degradation processes in transmission-class cable joints is very important to the reliability of the operating system. Degradation caused by partial discharges (PD) and their associated characteristics were investigated in model "pre-fabricated" cable joints. Time to breakdown and PD pulse parameters such as rise time, width, fall time, amplitude and frequency were studied. The paper further describes PD pulse parameters occurring within different part of cable joints, such as within the epoxy casting near the high voltage electrode and along the EPR-epoxy interfaces.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
模型节理界面局部放电脉冲形状的研究
了解传输级电缆接头的退化过程对操作系统的可靠性非常重要。研究了“预制”模型电缆接头局部放电引起的退化及其相关特性。对击穿时间、上升时间、宽度、下降时间、幅度和频率等参数进行了研究。本文进一步描述了在电缆接头的不同部位,如高压电极附近的环氧铸件内以及epr -环氧树脂界面内发生的PD脉冲参数。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Transient, finite element-boundary element methods for modeling high field effects in nonhomogeneous solid dielectrics Highly sensitive humidity sensor for dielectric measurement (water absorption) in glass-fiber resins Evaluation of cumulative charge data of polymer insulator aging tests Application of polyethylene sheath and swelling powder against water treeing Surface behaviour of epoxy castings during the early ageing period
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1