Dissolution Profiles of Glibenclamide Tablet Using Flow-Through-Cell Method

M. Iwata, Yuri Takahashi, H. Takeuchi, E. Kawahara, K. Takayama, Shoichi Shirotake
{"title":"Dissolution Profiles of Glibenclamide Tablet Using Flow-Through-Cell Method","authors":"M. Iwata, Yuri Takahashi, H. Takeuchi, E. Kawahara, K. Takayama, Shoichi Shirotake","doi":"10.5649/jjphcs1975.25.131","DOIUrl":null,"url":null,"abstract":"Operating conditions affecting the dissolution characteristics of glibenclamide were investigated with the flow-through-cell method (the third method of dissolution test in JP XIII). The partition coefficient of glibenclamide between octanol and phosphate buffer (pH 7.4) was observed to be 24.2, thus suggesting the lipophilic nature of glibenclamide. The flow indicator on the apparatus in the flow-through-cell method did not reflect the real flow rate of the dissolution media.The dissolution-time curve (ADT) value increased in line with the decrease in the bead's diameter when the flow rate of the indicator was slow (8 ml/min). On the other hand, the ADT value was hardly affected by the bead's diameter when the flow rate was fast (24 ml/min), however, a wide deviation in the ADT values was seen during such conditions. The operating condition of flow rate and bead's diameter was optimized based on the response surface method. As a result, a flow rate of 14 ml/min and a bead diameter of 0.5 mm were estimated as the optimal conditions to obtain the largest ADT and the smallest deviation in the ADT. When using the fl ow-through-cell method, the operating condition should be optimized based on the nature of pharmaceuticals under test.","PeriodicalId":17399,"journal":{"name":"Journal of the Nippon Hospital Pharmacists Association","volume":"8 1","pages":"131-137"},"PeriodicalIF":0.0000,"publicationDate":"1999-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of the Nippon Hospital Pharmacists Association","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5649/jjphcs1975.25.131","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Operating conditions affecting the dissolution characteristics of glibenclamide were investigated with the flow-through-cell method (the third method of dissolution test in JP XIII). The partition coefficient of glibenclamide between octanol and phosphate buffer (pH 7.4) was observed to be 24.2, thus suggesting the lipophilic nature of glibenclamide. The flow indicator on the apparatus in the flow-through-cell method did not reflect the real flow rate of the dissolution media.The dissolution-time curve (ADT) value increased in line with the decrease in the bead's diameter when the flow rate of the indicator was slow (8 ml/min). On the other hand, the ADT value was hardly affected by the bead's diameter when the flow rate was fast (24 ml/min), however, a wide deviation in the ADT values was seen during such conditions. The operating condition of flow rate and bead's diameter was optimized based on the response surface method. As a result, a flow rate of 14 ml/min and a bead diameter of 0.5 mm were estimated as the optimal conditions to obtain the largest ADT and the smallest deviation in the ADT. When using the fl ow-through-cell method, the operating condition should be optimized based on the nature of pharmaceuticals under test.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
流式细胞法测定格列本脲片的溶出度
采用流式细胞法(JP XIII中溶出度试验的第三种方法)考察了影响格列本脲溶出度的操作条件,观察到格列本脲在辛醇与磷酸盐缓冲液(pH 7.4)之间的分配系数为24.2,表明格列本脲具有亲脂性。在流式细胞法中,仪器上的流量指示器不能反映溶解介质的实际流速。当示踪剂流速较慢(8 ml/min)时,溶出时间曲线(ADT)值随微球直径减小而增大。另一方面,当流速较快(24 ml/min)时,ADT值几乎不受珠粒直径的影响,但在此条件下,ADT值偏差较大。基于响应面法对流量和水珠直径的工况进行了优化。结果表明,流速为14 ml/min,药珠直径为0.5 mm是获得最大ADT和最小ADT偏差的最佳条件。采用流式细胞法时,应根据被试药物的性质对操作条件进行优化。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
An Analysis of Urate-Lowering Drugs Using a Prescription Database 球形吸着炭 (クレメジン原体) の胆汁酸吸着性 癌化学療法時の口内炎に対するプロスタンディン®軟膏・アルロイドG液混合製剤の有効性 Collaboration of Hospital Pharmacists with Pharmaceutical College on Evaluation of Generic Drugs : The Case of Dissolution Test of Sodium Loxoprofen Tablets A Case Report and Evaluation of Pirmenol Toxicity Appeared with Liver Injury
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1