Determination of Acetaminophen in the Presence of Ascorbic Acid at Poly(m-Aminobenzene Sulfonic Acid) Conducting Polymer Electrode

G. Erdoğdu
{"title":"Determination of Acetaminophen in the Presence of Ascorbic Acid at Poly(m-Aminobenzene Sulfonic Acid) Conducting Polymer Electrode","authors":"G. Erdoğdu","doi":"10.1166/eef.2023.1269","DOIUrl":null,"url":null,"abstract":"The electrooxidation of Acetaminophen (AC) was accomplished by CV and differential pulse voltammetry at poly(m-aminobenzene sulfonic acid) (MABSA) modified sensor. As a result of the findings, the current values were enhanced and both substances were separated at the modified sensor\n compared to the bare electrode. A sensitive and simple modified sensor was prepared by electrodeposition of MABSA to the glassy carbon (GC) electrode surface by CV technique. There was linearly between the oxidation current and concentration of AC from 0.0 to 100 μM in phospate buffer\n solution at pH 7.0. The limit of detection was 2.0 nM and the sensitivity was 0.3203 μA/μM. The determination of AC was successfully and satisfactorily carried out in real samples such as human blood serum and urine at the poly (MABSA) sensor.","PeriodicalId":11683,"journal":{"name":"Energy and Environment Focus","volume":"57 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Energy and Environment Focus","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1166/eef.2023.1269","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The electrooxidation of Acetaminophen (AC) was accomplished by CV and differential pulse voltammetry at poly(m-aminobenzene sulfonic acid) (MABSA) modified sensor. As a result of the findings, the current values were enhanced and both substances were separated at the modified sensor compared to the bare electrode. A sensitive and simple modified sensor was prepared by electrodeposition of MABSA to the glassy carbon (GC) electrode surface by CV technique. There was linearly between the oxidation current and concentration of AC from 0.0 to 100 μM in phospate buffer solution at pH 7.0. The limit of detection was 2.0 nM and the sensitivity was 0.3203 μA/μM. The determination of AC was successfully and satisfactorily carried out in real samples such as human blood serum and urine at the poly (MABSA) sensor.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
聚间氨基苯磺酸导电聚合物电极上抗坏血酸存在时对乙酰氨基酚的测定
在聚间氨基苯磺酸(MABSA)修饰的传感器上,采用CV和差分脉冲伏安法完成了对乙酰氨基酚(AC)的电氧化。由于这些发现,与裸电极相比,电流值得到了增强,两种物质在改进的传感器上被分离。利用CV技术将MABSA电沉积在GC电极表面,制备了一种灵敏、简便的改性传感器。在pH 7.0的磷酸盐缓冲溶液中,氧化电流与AC浓度在0.0 ~ 100 μM范围内呈线性关系。检测限为2.0 nM,灵敏度为0.3203 μA/μM。在实际样品(如人血清和尿液)中,聚(MABSA)传感器可成功、满意地测定AC。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Analysis of the Effect of Hybridization of Coconut Shell Particles on Kenaf-Coir Based Epoxy Hybrid Composites Nanocubes SnO2 Thin Films for the Detection of CO Gas Isolation and Identification of Salt-Tolerant Mangrove Endophyte from Red Sea Coast Jeddah, Saudi Arabia Voltammetric Detection of Ascorbic Acid at Organic Conducting Polymers Electrodes and Flow Injection Analysis Dielectric Response of Strontium Titanate (SrTiO3)/Polycarbonate Nanocomposite Electrodes for Energy Storage
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1