{"title":"Comparison of PDA and EMI diagnostic measurements [for machine insulation]","authors":"J. Timperley","doi":"10.1109/ELINSL.2002.996004","DOIUrl":null,"url":null,"abstract":"There are two methods available for the online monitoring of mica-based insulation associated with high-voltage machines. Partial discharge analysis, PDA, is a time domain technique that measures and classifies electrical impulses that often occur at stator defects. Electromagnetic interference analysis, EMI, is a frequency domain technique that captures and classifies most of the high frequency electrical spectrum. This can include stator related defects as well as nonmachine related information. This paper presents a laboratory comparison of data collected by these two methods during the electrical aging of an 18 kV generator stator bar. These two techniques were found to produce similar results.","PeriodicalId":10532,"journal":{"name":"Conference Record of the the 2002 IEEE International Symposium on Electrical Insulation (Cat. No.02CH37316)","volume":"2015 1","pages":"575-578"},"PeriodicalIF":0.0000,"publicationDate":"2002-04-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"9","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Conference Record of the the 2002 IEEE International Symposium on Electrical Insulation (Cat. No.02CH37316)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ELINSL.2002.996004","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 9

Abstract

There are two methods available for the online monitoring of mica-based insulation associated with high-voltage machines. Partial discharge analysis, PDA, is a time domain technique that measures and classifies electrical impulses that often occur at stator defects. Electromagnetic interference analysis, EMI, is a frequency domain technique that captures and classifies most of the high frequency electrical spectrum. This can include stator related defects as well as nonmachine related information. This paper presents a laboratory comparison of data collected by these two methods during the electrical aging of an 18 kV generator stator bar. These two techniques were found to produce similar results.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
PDA和EMI诊断测量的比较[用于机器绝缘]
有两种方法可用于与高压机器相关的云母基绝缘的在线监测。局部放电分析(PDA)是一种时域技术,用于测量和分类经常发生在定子缺陷处的电脉冲。电磁干扰分析(EMI)是一种捕捉和分类大多数高频频谱的频域技术。这可以包括与定子相关的缺陷以及与非机器相关的信息。本文对18kv发电机定子棒电老化过程中两种方法采集的数据进行了实验室对比。人们发现这两种技术产生了相似的结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
After-installation test of HV extruded cable insulation Experimental investigation into the thermal-ageing of Kraft paper and mineral insulating oil Enhanced online PD evaluation on power transformers using wavelet techniques and frequency rejection filter for noise suppression On-line PD detection, requirements for practical use PD site location in distribution power cables
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1