Rapid high-performance sample digestion of base metal ores using high-intensity infrared radiation with determination by nitrogen-based microwave plasma optical spectrometry

Yong Wang, Laura A. Baker, Erick Helmeczi, Ian D. Brindle
{"title":"Rapid high-performance sample digestion of base metal ores using high-intensity infrared radiation with determination by nitrogen-based microwave plasma optical spectrometry","authors":"Yong Wang,&nbsp;Laura A. Baker,&nbsp;Erick Helmeczi,&nbsp;Ian D. Brindle","doi":"10.1016/j.ancr.2016.02.002","DOIUrl":null,"url":null,"abstract":"<div><p>Infrared sample digestion technology has been rapidly developed in recent years and its application and digestion performance on a variety of ores of base metals was assessed in this study, using a 6-channel infrared digester. Digestion times of 10 min or less were achieved for all base metal ores investigated, including oxides, sulfides, and silicates of Co, Cr, Cu, Fe, Mn, Mo, Ni, Pb, Sb, Ti, W, and Zn. Performance criteria for all samples were excellent, reflected in z values of less than 2 in all cases. Various acid digestion methods were developed for the selected ore samples under high intensity infrared radiation and delivered virtually complete recoveries of all of the elements of interest. Chromite, the notoriously refractory chromium ore was digested within 10 min and gave 100% recovery of chromium. These digestions were accomplished without resorting to perchloric acid and, for most sample types, without hydrofluoric acid, significantly improving the workplace safety for analysts. Between-channel variation of the analyte recoveries from the 6-channel unit were generally below 2%, suggesting that the digestion methods developed with this platform provide reproducible results to meet various sample preparation demands. The high speed and analyte recovery of these digestions makes this methodology especially attractive for prospectors and developers who demand rapid and reliable results from exploration samples.</p></div>","PeriodicalId":7819,"journal":{"name":"Analytical Chemistry Research","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2016-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/j.ancr.2016.02.002","citationCount":"11","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analytical Chemistry Research","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2214181216300027","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 11

Abstract

Infrared sample digestion technology has been rapidly developed in recent years and its application and digestion performance on a variety of ores of base metals was assessed in this study, using a 6-channel infrared digester. Digestion times of 10 min or less were achieved for all base metal ores investigated, including oxides, sulfides, and silicates of Co, Cr, Cu, Fe, Mn, Mo, Ni, Pb, Sb, Ti, W, and Zn. Performance criteria for all samples were excellent, reflected in z values of less than 2 in all cases. Various acid digestion methods were developed for the selected ore samples under high intensity infrared radiation and delivered virtually complete recoveries of all of the elements of interest. Chromite, the notoriously refractory chromium ore was digested within 10 min and gave 100% recovery of chromium. These digestions were accomplished without resorting to perchloric acid and, for most sample types, without hydrofluoric acid, significantly improving the workplace safety for analysts. Between-channel variation of the analyte recoveries from the 6-channel unit were generally below 2%, suggesting that the digestion methods developed with this platform provide reproducible results to meet various sample preparation demands. The high speed and analyte recovery of these digestions makes this methodology especially attractive for prospectors and developers who demand rapid and reliable results from exploration samples.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
利用高强度红外辐射快速高效地消解贱金属矿石样品,并用氮基微波等离子体光谱法测定
红外样品消解技术是近年来迅速发展起来的一项技术,本文利用6通道红外消解器,对红外消解技术在多种贱金属矿石中的应用及消解性能进行了评价。所有被研究的贱金属矿石,包括Co、Cr、Cu、Fe、Mn、Mo、Ni、Pb、Sb、Ti、W和Zn的氧化物、硫化物和硅酸盐,消解时间均在10分钟或更短。所有样本的性能标准都很好,在所有情况下z值都小于2。在高强度红外辐射下,对选定的矿石样品开发了各种酸消解方法,并几乎完全回收了所有感兴趣的元素。铬铁矿是出了名的难熔铬矿,在10分钟内被消化,铬的回收率达到100%。这些消化在不使用高氯酸的情况下完成,对于大多数样品类型,不使用氢氟酸,大大提高了分析人员工作场所的安全性。6通道单元的分析物回收率的通道间变化通常低于2%,表明该平台开发的消化方法具有可重复性,可满足各种样品制备要求。这些消化的高速度和分析物回收率使这种方法对要求从勘探样品中获得快速可靠结果的勘探者和开发商特别有吸引力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Chemically modified carbon paste ion-selective electrodes for determination of atorvastatin calcium in pharmaceutical preparations Preparation and characterization of a novel Co(II) optode based on polymer inclusion membrane Structural identification and estimation of Rosuvastatin calcium related impurities in Rosuvastatin calcium tablet dosage form Comparative sensing of aldehyde and ammonia vapours on synthetic polypyrrole-Sn(IV)arsenotungstate nanocomposite cation exchange material Nano clay Ni/NiO nanocomposite new sorbent for separation and preconcentration dibenzothiophene from crude prior to UV–vis spectrophotometery determination
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1