Correction of Skeletal Openbite Using Zygomatic Miniplates

S. Dadgar, F. Sobouti, Mehran Armin, Nasim Esnaashari
{"title":"Correction of Skeletal Openbite Using Zygomatic Miniplates","authors":"S. Dadgar, F. Sobouti, Mehran Armin, Nasim Esnaashari","doi":"10.9734/bjmmr/2017/30193","DOIUrl":null,"url":null,"abstract":"Aims: Anterior open bite is often caused by excessive vertical development of the posterior maxilla. In such cases, it is hardly possible to establish absolute anchorage for molar intrusion by traditional orthodontic mechanics. The use of skeletal anchorage for orthodontic tooth movement is offering a minimally invasive treatment option for correction of skeletal anterior open bite and enhancement of facial esthetics as an alternative to major surgery. Presentation of Case: This article reports a case of 23 year old female patient, who had a moderately severe skeletal anterior open bite, that was successfully corrected by using titanium miniplates and miniscrews. The miniplate were inserted in zygomaticomaxillary buttress area and fixed with two miniscrews on each side. Titanium miniscrews were inserted bilaterally in palatal region to preserve molar axial inclination during intrusion. An intrusion force was provided with niti coilsprings for 9 months. Discussion: After active treatment of 24 months, The mean amount of accomplished molar intrusion was 2.8 mm ± 0.64 mm, with a rate of 0.311 mm ± 0.071 mm per month and a bite closure of 5.61 mm ± 1.23 mm. No significant buccal tip was observed in the right and left molars Case Report Dadgar et al.; BJMMR, 19(6): 1-10, 2017; Article no.BJMMR.30193 2 upon intrusion. Her retrognathic chin and convex profiles were improved by counterclockwise rotation of the mandible. Conclusion: Our results suggest that titanium miniplates are useful for intrusion of posterior teeth. Intrusion of the posterior teeth induced counterclockwise rotation of the mandible and, as a consequence, corrected the anteroposterior intermaxillary relationship with a significant improvement in the facial soft tissue convexity.","PeriodicalId":9249,"journal":{"name":"British journal of medicine and medical research","volume":"5 1","pages":"1-10"},"PeriodicalIF":0.0000,"publicationDate":"2017-01-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"British journal of medicine and medical research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.9734/bjmmr/2017/30193","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

Aims: Anterior open bite is often caused by excessive vertical development of the posterior maxilla. In such cases, it is hardly possible to establish absolute anchorage for molar intrusion by traditional orthodontic mechanics. The use of skeletal anchorage for orthodontic tooth movement is offering a minimally invasive treatment option for correction of skeletal anterior open bite and enhancement of facial esthetics as an alternative to major surgery. Presentation of Case: This article reports a case of 23 year old female patient, who had a moderately severe skeletal anterior open bite, that was successfully corrected by using titanium miniplates and miniscrews. The miniplate were inserted in zygomaticomaxillary buttress area and fixed with two miniscrews on each side. Titanium miniscrews were inserted bilaterally in palatal region to preserve molar axial inclination during intrusion. An intrusion force was provided with niti coilsprings for 9 months. Discussion: After active treatment of 24 months, The mean amount of accomplished molar intrusion was 2.8 mm ± 0.64 mm, with a rate of 0.311 mm ± 0.071 mm per month and a bite closure of 5.61 mm ± 1.23 mm. No significant buccal tip was observed in the right and left molars Case Report Dadgar et al.; BJMMR, 19(6): 1-10, 2017; Article no.BJMMR.30193 2 upon intrusion. Her retrognathic chin and convex profiles were improved by counterclockwise rotation of the mandible. Conclusion: Our results suggest that titanium miniplates are useful for intrusion of posterior teeth. Intrusion of the posterior teeth induced counterclockwise rotation of the mandible and, as a consequence, corrected the anteroposterior intermaxillary relationship with a significant improvement in the facial soft tissue convexity.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
颧骨微型钢板矫正骨开咬
目的:前开牙合多由后上颌骨垂直发育过度引起。在这种情况下,传统的正畸力学几乎不可能建立磨牙侵入的绝对支抗。使用骨锚定矫治牙齿的运动提供了一种微创治疗选择,以纠正骨前开咬和增强面部美观,作为大手术的替代。病例介绍:本文报告一例23岁的女性患者,患有中度严重的骨前开咬,使用微型钛板和微型钛钉成功矫正。将微型钢板置入颧颌支撑区,两侧各用两颗微型螺钉固定。在腭区两侧插入钛微型螺钉,以保持磨牙在侵入过程中的轴向倾斜。用镍钛线圈弹簧提供侵入力9个月。讨论:积极治疗24个月后,平均完成磨牙侵入量为2.8 mm±0.64 mm,每月0.311 mm±0.071 mm,咬合量为5.61 mm±1.23 mm。右磨牙和左磨牙未观察到明显的颊尖。地球物理学报,19(6):1-10,2017;文章no.BJMMR。30193 .一旦入侵。下颌逆时针旋转改善了她的下颌后凸轮廓。结论:微型钛板对后牙内嵌有较好的效果。后牙的侵入引起下颌骨的逆时针旋转,从而纠正了前后颌间的关系,显著改善了面部软组织的凹凸度。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Pattern and Trends of Respiratory Disease Admissions at the Emergency Paediatrics Unit of Jos University Teaching Hospital – A Four Year Review Acquisition of Competence in Clinical Practical Procedures: A Model of the University of Zambia Medical School nternal Medicine as a Career Choice among Rotatory Interns in a Developing Country- A Multi Centre Study Appreciating the Essence of Post Natal Care Services from Mothers’ Perspective in Kiambu, Kenya Phenylthiocarbamide Taste Perception among HIV- Infected Patients on Highly Active Antiretroviral Therapy
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1