Complete Capsular Repair Using a Knotless Barbed Suture With a Mini-direct Lateral Approach for Total Hip Arthroplasty: A Technique Note and Feasibility Study
N. Kobayashi, Y. Yukizawa, S. Takagawa, Hideki Honda, Kensuke Kameda, Y. Inaba
{"title":"Complete Capsular Repair Using a Knotless Barbed Suture With a Mini-direct Lateral Approach for Total Hip Arthroplasty: A Technique Note and Feasibility Study","authors":"N. Kobayashi, Y. Yukizawa, S. Takagawa, Hideki Honda, Kensuke Kameda, Y. Inaba","doi":"10.1097/BTO.0000000000000609","DOIUrl":null,"url":null,"abstract":"Introduction: How the hip joint capsule is processed during total hip arthroplasty (THA) and whether a capsular repair is needed, are important factors determining the success of the procedure. In this surgical technique report, we present a detailed technical discussion of the pearls and pitfalls of complete capsular repair using knotless barbed sutures for a mini-direct lateral approach THA. Materials and Methods: A total of 45 consecutive cases that underwent a mini-direct lateral approach for THA with a complete capsular repair were included. A historical control group of 169 cases with partial capsulectomy without repair were also reviewed. This technique is based on a modified mini-incision direct lateral approach. A T-shaped capsulotomy was performed. The margin to be seamed at the femoral side of the capsular ligament must be preserved. A knotless barbed suture was applied for repairing the capsular ligament and gluteus minimus. Results: In 42 cases (93.3%), a complete capsular repair was achieved successfully. The average operative time was 106±20 minutes. The average intraoperative bleeding was 369±241 mL. There was no major complication both intra and postoperatively. Conclusion: Complete capsular repair through a mini-direct lateral approach was feasible by using a knotless barbed suture. Preserving the margin used to seam the femoral side of the capsular ligament is a key requirement for reattachment of the capsule. In addition, a continuous knotless barbed suture facilitates gradual plication of the capsule without a cheese cut.","PeriodicalId":45336,"journal":{"name":"Techniques in Orthopaedics","volume":"67 1","pages":"80 - 84"},"PeriodicalIF":0.2000,"publicationDate":"2022-10-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Techniques in Orthopaedics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1097/BTO.0000000000000609","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0
Abstract
Introduction: How the hip joint capsule is processed during total hip arthroplasty (THA) and whether a capsular repair is needed, are important factors determining the success of the procedure. In this surgical technique report, we present a detailed technical discussion of the pearls and pitfalls of complete capsular repair using knotless barbed sutures for a mini-direct lateral approach THA. Materials and Methods: A total of 45 consecutive cases that underwent a mini-direct lateral approach for THA with a complete capsular repair were included. A historical control group of 169 cases with partial capsulectomy without repair were also reviewed. This technique is based on a modified mini-incision direct lateral approach. A T-shaped capsulotomy was performed. The margin to be seamed at the femoral side of the capsular ligament must be preserved. A knotless barbed suture was applied for repairing the capsular ligament and gluteus minimus. Results: In 42 cases (93.3%), a complete capsular repair was achieved successfully. The average operative time was 106±20 minutes. The average intraoperative bleeding was 369±241 mL. There was no major complication both intra and postoperatively. Conclusion: Complete capsular repair through a mini-direct lateral approach was feasible by using a knotless barbed suture. Preserving the margin used to seam the femoral side of the capsular ligament is a key requirement for reattachment of the capsule. In addition, a continuous knotless barbed suture facilitates gradual plication of the capsule without a cheese cut.
D. Lepelletier , R. Bonnet , P. Plésiat , M.H. Nicolas-Chanoine , A. Berger-Carbonne , C. Chidiac , B. Grandbastien , national working group from the French High Council of Public Health
期刊介绍:
The purpose of Techniques in Orthopaedics is to provide information on the latest orthopaedic procedure as they are devised and used by top orthopaedic surgeons. The approach is technique-oriented, covering operations, manipulations, and instruments being developed and applied in such as arthroscopy, arthroplasty, and trauma. Each issue is guest-edited by an expert in the field and devoted to a single topic.