{"title":"Operations Using a Frameless Stereotactic System with a Marker: Technical Note","authors":"T. Kuroiwa, T. Ohta","doi":"10.1055/S-2001-18125","DOIUrl":null,"url":null,"abstract":"One of the most critical problems in navigation systems is that of brain shifts during operations. In order to solve this problem, we developed a simple method using a marker placed prior to microsurgery to provide a reference point. We produced a thin probe. After the dural incision, the probe, covered with a silicone tube, was inserted into the target point. Then only the probe was removed, leaving the silicone tube in place. This tube moved together with the brain, which deviated during the operation, and throughout the operation indicated the same point as that which it was pointed at first. This result suggests that this is a simple and useful method to allow navigation systems to accommodate brain shifts during operations.","PeriodicalId":49808,"journal":{"name":"Minimally Invasive Neurosurgery","volume":"46 1","pages":"163 - 166"},"PeriodicalIF":0.0000,"publicationDate":"2001-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Minimally Invasive Neurosurgery","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1055/S-2001-18125","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

Abstract

One of the most critical problems in navigation systems is that of brain shifts during operations. In order to solve this problem, we developed a simple method using a marker placed prior to microsurgery to provide a reference point. We produced a thin probe. After the dural incision, the probe, covered with a silicone tube, was inserted into the target point. Then only the probe was removed, leaving the silicone tube in place. This tube moved together with the brain, which deviated during the operation, and throughout the operation indicated the same point as that which it was pointed at first. This result suggests that this is a simple and useful method to allow navigation systems to accommodate brain shifts during operations.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
使用带标记的无框立体定向系统的操作:技术说明
导航系统中最关键的问题之一是操作过程中大脑的变化。为了解决这个问题,我们开发了一种简单的方法,使用显微手术前放置的标记来提供参考点。我们制作了一个薄探针。在硬脑膜切开后,用硅胶管覆盖探针插入目标点。然后只取出探针,留下硅胶管。这根管子和大脑一起移动,大脑在手术过程中发生了偏移,在整个手术过程中,它指向的点和最初指向的点是一样的。这一结果表明,这是一种简单而有用的方法,可以让导航系统适应手术过程中大脑的变化。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Minimally Invasive Neurosurgery
Minimally Invasive Neurosurgery 医学-临床神经学
自引率
0.00%
发文量
0
审稿时长
>12 weeks
期刊最新文献
We would like to thank the following persons who reviewed MIN manuscripts for their expertise and support in the year 2010: Reply to the comment of R. Härtl: The Future of “Minimally Invasive Neurosurgery” Simultaneous Treatment of a Pituitary Adenoma and an Internal Carotid Artery Aneurysm Through a Supraorbital Keyhole Approach Endoscopic Fenestration of Symptomatic Septum Pellucidum Cysts: Three Case Reports with Discussion on the Approaches and Technique
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1