TH-E-M100F-06: Estimation of the Error in Internal Target Volume (ITV) of Lung Tumor Obtained From Free-Breathing Cine-Mode 4DCT: A Simulation and Comparison Study Based On Dynamic MRI

IF 3.2 2区 医学 Q1 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING Medical physics Pub Date : 2007-06-11 DOI:10.1118/1.2761752
J Cai, P Read, J Baisden, J Larner, S Benedict, K Sheng
{"title":"TH-E-M100F-06: Estimation of the Error in Internal Target Volume (ITV) of Lung Tumor Obtained From Free-Breathing Cine-Mode 4DCT: A Simulation and Comparison Study Based On Dynamic MRI","authors":"J Cai,&nbsp;P Read,&nbsp;J Baisden,&nbsp;J Larner,&nbsp;S Benedict,&nbsp;K Sheng","doi":"10.1118/1.2761752","DOIUrl":null,"url":null,"abstract":"<p><b>Purpose:</b> To quantitate the error of tumor internal target volume (ITV) as determined from simulated free-breathing cine-mode 4DCT using dynamic magnetic resonance imaging (dMRI). <b>Method and Materials:</b> 8 healthy volunteers and 6 lung tumor patients underwent a 5-minute MRI scan in the sagittal plane to acquire dynamic images of lung motion. A MATLAB program was written to simulate the cine-mode 4DCT acquisition by segmenting and resorting the MR images. Maximum intensity projection (MIP) images were generated from both simulated 4DCT (sCT) and dMRI, and the errors in MIP-based ITV from sCT (ε), comparing to those from dMRI, were determined and correlate to the subjects' respiratory variability (ν). <b>Results:</b> MIP-based ITVs from sCT were comparatively smaller than those from dMRI in both digital-phantom studies (ε=−21.64±8.23%) and lung tumor patient studies (ε=−20.31±11.36%). The errors in MIP-based ITV from sCT linearly correlated (, r<sup>2</sup>=0.76) with the subjects' respiratory variability.</p><p><b>Conclusions:</b> Because of the low temporal resolution and retrospective resorting, 4DCT may not accurately depict the excursion of a moving tumor. Using 4DCT MIP image to define ITV may therefore cause under-dosing and increased risk of subsequent treatment failure. Patient-specific respiratory variability may also be a useful predictor of the 4DCT-induced error in MIP-based ITV determination.</p>","PeriodicalId":18384,"journal":{"name":"Medical physics","volume":"34 6Part24","pages":"2648"},"PeriodicalIF":3.2000,"publicationDate":"2007-06-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Medical physics","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1118/1.2761752","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: To quantitate the error of tumor internal target volume (ITV) as determined from simulated free-breathing cine-mode 4DCT using dynamic magnetic resonance imaging (dMRI). Method and Materials: 8 healthy volunteers and 6 lung tumor patients underwent a 5-minute MRI scan in the sagittal plane to acquire dynamic images of lung motion. A MATLAB program was written to simulate the cine-mode 4DCT acquisition by segmenting and resorting the MR images. Maximum intensity projection (MIP) images were generated from both simulated 4DCT (sCT) and dMRI, and the errors in MIP-based ITV from sCT (ε), comparing to those from dMRI, were determined and correlate to the subjects' respiratory variability (ν). Results: MIP-based ITVs from sCT were comparatively smaller than those from dMRI in both digital-phantom studies (ε=−21.64±8.23%) and lung tumor patient studies (ε=−20.31±11.36%). The errors in MIP-based ITV from sCT linearly correlated (, r2=0.76) with the subjects' respiratory variability.

Conclusions: Because of the low temporal resolution and retrospective resorting, 4DCT may not accurately depict the excursion of a moving tumor. Using 4DCT MIP image to define ITV may therefore cause under-dosing and increased risk of subsequent treatment failure. Patient-specific respiratory variability may also be a useful predictor of the 4DCT-induced error in MIP-based ITV determination.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
TH-E-M100F-06:自由呼吸影像模式4DCT肺肿瘤内靶体积(ITV)误差估计:基于动态MRI的模拟与比较研究
目的:量化动态磁共振成像(dMRI)模拟自由呼吸电影模式4DCT测定肿瘤内部靶体积(ITV)的误差。方法与材料:对8名健康志愿者和6名肺肿瘤患者进行5分钟矢状面MRI扫描,获取肺运动的动态图像。编写了MATLAB程序,模拟了对MR图像进行分割和诉诸的电影模式4DCT采集。模拟4DCT (sCT)和dMRI均生成了最大强度投影(MIP)图像,与dMRI相比,sCT基于MIP的ITV误差(ε)被确定并与受试者的呼吸变异性(ν)相关。结果:在指影研究(ε= - 21.64±8.23%)和肺肿瘤患者研究(ε= - 20.31±11.36%)中,sCT基于mip的ITVs相对小于dMRI。sCT基于mip的ITV误差与受试者的呼吸变异性呈线性相关(r2=0.76)。结论:由于低时间分辨率和回顾性求助,4DCT可能不能准确描述移动肿瘤的偏移。因此,使用4DCT MIP图像来定义ITV可能会导致剂量不足和后续治疗失败的风险增加。在基于mip的ITV测定中,患者特异性呼吸变异性也可能是4dct引起的误差的有用预测因子。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Medical physics
Medical physics 医学-核医学
CiteScore
6.80
自引率
15.80%
发文量
660
审稿时长
1.7 months
期刊介绍: Medical Physics publishes original, high impact physics, imaging science, and engineering research that advances patient diagnosis and therapy through contributions in 1) Basic science developments with high potential for clinical translation 2) Clinical applications of cutting edge engineering and physics innovations 3) Broadly applicable and innovative clinical physics developments Medical Physics is a journal of global scope and reach. By publishing in Medical Physics your research will reach an international, multidisciplinary audience including practicing medical physicists as well as physics- and engineering based translational scientists. We work closely with authors of promising articles to improve their quality.
期刊最新文献
Issue Information Cover List of Advertisers Issue Information List of Advertisers
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1