TH-E-M100F-06: Estimation of the Error in Internal Target Volume (ITV) of Lung Tumor Obtained From Free-Breathing Cine-Mode 4DCT: A Simulation and Comparison Study Based On Dynamic MRI
J Cai, P Read, J Baisden, J Larner, S Benedict, K Sheng
{"title":"TH-E-M100F-06: Estimation of the Error in Internal Target Volume (ITV) of Lung Tumor Obtained From Free-Breathing Cine-Mode 4DCT: A Simulation and Comparison Study Based On Dynamic MRI","authors":"J Cai, P Read, J Baisden, J Larner, S Benedict, K Sheng","doi":"10.1118/1.2761752","DOIUrl":null,"url":null,"abstract":"<p><b>Purpose:</b> To quantitate the error of tumor internal target volume (ITV) as determined from simulated free-breathing cine-mode 4DCT using dynamic magnetic resonance imaging (dMRI). <b>Method and Materials:</b> 8 healthy volunteers and 6 lung tumor patients underwent a 5-minute MRI scan in the sagittal plane to acquire dynamic images of lung motion. A MATLAB program was written to simulate the cine-mode 4DCT acquisition by segmenting and resorting the MR images. Maximum intensity projection (MIP) images were generated from both simulated 4DCT (sCT) and dMRI, and the errors in MIP-based ITV from sCT (ε), comparing to those from dMRI, were determined and correlate to the subjects' respiratory variability (ν). <b>Results:</b> MIP-based ITVs from sCT were comparatively smaller than those from dMRI in both digital-phantom studies (ε=−21.64±8.23%) and lung tumor patient studies (ε=−20.31±11.36%). The errors in MIP-based ITV from sCT linearly correlated (, r<sup>2</sup>=0.76) with the subjects' respiratory variability.</p><p><b>Conclusions:</b> Because of the low temporal resolution and retrospective resorting, 4DCT may not accurately depict the excursion of a moving tumor. Using 4DCT MIP image to define ITV may therefore cause under-dosing and increased risk of subsequent treatment failure. Patient-specific respiratory variability may also be a useful predictor of the 4DCT-induced error in MIP-based ITV determination.</p>","PeriodicalId":18384,"journal":{"name":"Medical physics","volume":"34 6Part24","pages":"2648"},"PeriodicalIF":3.2000,"publicationDate":"2007-06-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Medical physics","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1118/1.2761752","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0
Abstract
Purpose: To quantitate the error of tumor internal target volume (ITV) as determined from simulated free-breathing cine-mode 4DCT using dynamic magnetic resonance imaging (dMRI). Method and Materials: 8 healthy volunteers and 6 lung tumor patients underwent a 5-minute MRI scan in the sagittal plane to acquire dynamic images of lung motion. A MATLAB program was written to simulate the cine-mode 4DCT acquisition by segmenting and resorting the MR images. Maximum intensity projection (MIP) images were generated from both simulated 4DCT (sCT) and dMRI, and the errors in MIP-based ITV from sCT (ε), comparing to those from dMRI, were determined and correlate to the subjects' respiratory variability (ν). Results: MIP-based ITVs from sCT were comparatively smaller than those from dMRI in both digital-phantom studies (ε=−21.64±8.23%) and lung tumor patient studies (ε=−20.31±11.36%). The errors in MIP-based ITV from sCT linearly correlated (, r2=0.76) with the subjects' respiratory variability.
Conclusions: Because of the low temporal resolution and retrospective resorting, 4DCT may not accurately depict the excursion of a moving tumor. Using 4DCT MIP image to define ITV may therefore cause under-dosing and increased risk of subsequent treatment failure. Patient-specific respiratory variability may also be a useful predictor of the 4DCT-induced error in MIP-based ITV determination.
期刊介绍:
Medical Physics publishes original, high impact physics, imaging science, and engineering research that advances patient diagnosis and therapy through contributions in 1) Basic science developments with high potential for clinical translation 2) Clinical applications of cutting edge engineering and physics innovations 3) Broadly applicable and innovative clinical physics developments
Medical Physics is a journal of global scope and reach. By publishing in Medical Physics your research will reach an international, multidisciplinary audience including practicing medical physicists as well as physics- and engineering based translational scientists. We work closely with authors of promising articles to improve their quality.