{"title":"A self-consistent mass absorption correction for silicate analysis by X-ray fluorescence","authors":"J.G. Holland,&nbsp;D.W. Brindle","doi":"10.1016/0371-1951(66)80057-7","DOIUrl":null,"url":null,"abstract":"<div><p>Deviations from proportionality form the major source of error in X-ray fluorescent analysis. By careful preparation of the sample and equally careful operation of the spectrograph these deviations can be confined to inter-sample differences in total mass absorption. In order to eliminate or estimate these differences a variety of methods have been described; but none have found universal application. The method of a self-consistent mass absorption correction does not share the shortcomings of its predecessors. Without any pre-supposition regarding the over-all chemistry, an approximate composition of the unknown is first calculated by direct reference to a standard. Using this approximate composition the total mass absorption of the unknown is determined for each operational wavelength, and this information then used to make a more accurate estimate of the composition of the unknown. This more accurate estimate provides the means for determining a yet more accurate value for the total mass absorption at each wavelength. Thus, by an iterative process, a self-consistent chemical composition is obtained, and this value is then corrected for other deviations from proportionality by reference to a set of standards, using a quadratic regression relationship. Although this method has only been applied so far to whole rock analyses, its application could prove to be much more extensive, for the computer programme described is so constructed that, by a simple interchange of the matrix block and reference standards, analyses could be made within the entire range of the X-ray spectrum.</p></div>","PeriodicalId":101180,"journal":{"name":"Spectrochimica Acta","volume":"22 12","pages":"Pages 2083-2093"},"PeriodicalIF":0.0000,"publicationDate":"1966-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/0371-1951(66)80057-7","citationCount":"34","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Spectrochimica Acta","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/0371195166800577","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 34

Abstract

Deviations from proportionality form the major source of error in X-ray fluorescent analysis. By careful preparation of the sample and equally careful operation of the spectrograph these deviations can be confined to inter-sample differences in total mass absorption. In order to eliminate or estimate these differences a variety of methods have been described; but none have found universal application. The method of a self-consistent mass absorption correction does not share the shortcomings of its predecessors. Without any pre-supposition regarding the over-all chemistry, an approximate composition of the unknown is first calculated by direct reference to a standard. Using this approximate composition the total mass absorption of the unknown is determined for each operational wavelength, and this information then used to make a more accurate estimate of the composition of the unknown. This more accurate estimate provides the means for determining a yet more accurate value for the total mass absorption at each wavelength. Thus, by an iterative process, a self-consistent chemical composition is obtained, and this value is then corrected for other deviations from proportionality by reference to a set of standards, using a quadratic regression relationship. Although this method has only been applied so far to whole rock analyses, its application could prove to be much more extensive, for the computer programme described is so constructed that, by a simple interchange of the matrix block and reference standards, analyses could be made within the entire range of the X-ray spectrum.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
x射线荧光分析硅酸盐的自洽质量吸收校正
偏离比例是x射线荧光分析误差的主要来源。通过仔细制备样品和同样仔细地操作光谱仪,这些偏差可以限制在样品间总质量吸收的差异。为了消除或估计这些差异,已经描述了各种方法;但没有一种方法得到普遍应用。自洽质量吸收校正方法没有前人的缺点。在对整个化学过程没有任何预先假设的情况下,首先通过直接参考标准来计算未知物质的近似组成。利用这一近似组成,确定了每个工作波长的未知物质的总吸收质量,然后利用这一信息对未知物质的组成作出更准确的估计。这种更精确的估计为确定每个波长的总质量吸收的更精确的值提供了手段。因此,通过迭代过程,获得自洽的化学成分,然后通过参考一组标准,使用二次回归关系,对比例性的其他偏差进行校正。虽然这种方法到目前为止只应用于整个岩石的分析,但它的应用可以证明是更广泛的,因为所描述的计算机程序是这样构建的,通过简单地交换矩阵块和参考标准,可以在整个x射线光谱范围内进行分析。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Errata The dipole moment of rhodamine B from absorption spectrophotometry The fluorescence spectrum of benzo(f)quinoline Infra-red spectra of sulphamide and sulphamide-d4 Comments on the vibrational assignments of HBCl2 and HBBr2
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1