Evaluation of sealing between abutment and inner connection of cone morse dental implant

Derivaldo Moura Gois Filho, V. T. Gois-Santos, Ronaldo S. Silva, A. C. Marqueti, A. Cortes, C. L. Trento
{"title":"Evaluation of sealing between abutment and inner connection of cone morse dental implant","authors":"Derivaldo Moura Gois Filho, V. T. Gois-Santos, Ronaldo S. Silva, A. C. Marqueti, A. Cortes, C. L. Trento","doi":"10.11606/ISSN.2357-8041.CLRD.2018.147797","DOIUrl":null,"url":null,"abstract":"Introduction: The adaptation of prostheses fixed over implants involves biomechanical aspects that are directly associated with treatment success. Objective: The aim of this in vitro study was to evaluate the presence of microgaps in the abutment/inner connection interface of cone morse dental implants. Materials and methods: Two groups of implants were analyzed. The first group (n = 16) employed single-manufacturer dental implants and abutments, whereas the second group (n = 16) combined multi-manufacturer materials. The sets were analyzed through scanning electron mi­croscopy, wherein microgaps between the implant connection and the abutment were observed. Results: Group 1 had an average microgap of 5.69 μm (SD ± 8.46 μm). Group 2 had an average microgap of 1.24 μm (SD ± 0.44 μm). A significant difference was found between the two groups (p = 0.002). Conclusion: Within the limitations of this study, results suggest that the group formed by multi-manufacturer implants and abutments (group 2) had smaller microgap values, and, therefore, a higher in vitro adaptation of components. \nDESCRIPTORS | Dental Implants; Dental Abutments; Scanning Electron Microscopy.","PeriodicalId":10204,"journal":{"name":"Clinical and Laboratorial Research in Dentistry","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2018-09-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical and Laboratorial Research in Dentistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.11606/ISSN.2357-8041.CLRD.2018.147797","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

Abstract

Introduction: The adaptation of prostheses fixed over implants involves biomechanical aspects that are directly associated with treatment success. Objective: The aim of this in vitro study was to evaluate the presence of microgaps in the abutment/inner connection interface of cone morse dental implants. Materials and methods: Two groups of implants were analyzed. The first group (n = 16) employed single-manufacturer dental implants and abutments, whereas the second group (n = 16) combined multi-manufacturer materials. The sets were analyzed through scanning electron mi­croscopy, wherein microgaps between the implant connection and the abutment were observed. Results: Group 1 had an average microgap of 5.69 μm (SD ± 8.46 μm). Group 2 had an average microgap of 1.24 μm (SD ± 0.44 μm). A significant difference was found between the two groups (p = 0.002). Conclusion: Within the limitations of this study, results suggest that the group formed by multi-manufacturer implants and abutments (group 2) had smaller microgap values, and, therefore, a higher in vitro adaptation of components. DESCRIPTORS | Dental Implants; Dental Abutments; Scanning Electron Microscopy.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
锥形莫尔斯种植体基台与内连接间密封的评价
引言:假体固定在植入物上的适应性涉及生物力学方面,与治疗成功直接相关。目的:研究锥体莫尔斯种植体基牙/内连接界面存在微间隙的情况。材料和方法:对两组种植体进行分析。第一组(n = 16)采用单一制造商种植体和基台,而第二组(n = 16)采用多制造商材料组合。通过扫描电镜分析,观察种植体连接与基牙之间的微间隙。结果:1组平均微间隙为5.69 μm (SD±8.46 μm)。2组平均微间隙为1.24 μm (SD±0.44 μm)。两组间差异有统计学意义(p = 0.002)。结论:在本研究的限制范围内,结果表明由多厂家种植体和基台组成的组(2组)具有更小的微间隙值,因此组件的体外适应性更高。|牙种植体;牙髓牙;扫描电子显微镜。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Recorrências locais de tumores de glândulas salivares em uma população brasileira Utilização da distração óssea no tratamento de pacientes com Sequência de Pierre Robin Relação entre alterações ósseas detectadas na panorâmica e osteoporose Comparison of the accuracy of linear measurements in CBCT images with different field of views Antimicrobial photodynamic and photobiomodulation adjuvant therapies for medication-related osteonecrosis of the jaw – Report of two cases with long-term follow-up
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1