Canine retraction rate and angulation with 0.017”X0.025” versus Canine retraction rate and angulation with 0.017”X0.025” versus 0.016”X0.022” stainless steel arch wire with a power arm 0.016”X0.022” stainless steel arch wire with a power arm

A. Elbeialy, Fouad Elsharby, H. Elsayed
{"title":"Canine retraction rate and angulation with 0.017”X0.025” versus Canine retraction rate and angulation with 0.017”X0.025” versus 0.016”X0.022” stainless steel arch wire with a power arm 0.016”X0.022” stainless steel arch wire with a power arm","authors":"A. Elbeialy, Fouad Elsharby, H. Elsayed","doi":"10.54623/fdj.8013","DOIUrl":null,"url":null,"abstract":"Background: The dimensions of the arch wire affect its stiffness and the play between the wire and bracket. Canine retraction over stiffer arch wires limits the degree of canine tipping. However, the greater the wire dimensions, the greater the resistance to sliding. Frictional resistance is known to delay tooth movement. Aim: The aim of this controlled clinical trial was to compare canine retraction rate and angulation with 0.017”X0.025” versus 0.016”X0.022” stainless steel arch wire with a power arm. Materials and Methods: Twenty-four Class II malocclusion patients (age 13.8± 2.6 years) participated in this study. The teeth were leveled and aligned. Bilateral maxillary first premolars were extracted. In group A, the canines were retracted over 0.017”X0.025” wires. In group B, they were retracted using 0.016”X0.022” wires with a vertical power arm. The retraction force was 150g generated by elastomeric chains. The canine retraction rate and angulation were measured at the end of six months. The rates in the two groups were compared with the t-test and the angulation with the Mann Whitney test. Results: canine retraction rate was 4.64±1.5 in group A and 5.24±1.45 in group B. The canine angulation was 6.41±5.14 and 6.73±6.0 for group A and B, respectively. Conclusion: No difference was observed in the canine retraction rate or angulation with 0.017”X0.025” versus 0.016”X0.022” stainless steel arch wire with a power arm.","PeriodicalId":100562,"journal":{"name":"Future Dental Journal","volume":"69 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2022-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Future Dental Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.54623/fdj.8013","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Background: The dimensions of the arch wire affect its stiffness and the play between the wire and bracket. Canine retraction over stiffer arch wires limits the degree of canine tipping. However, the greater the wire dimensions, the greater the resistance to sliding. Frictional resistance is known to delay tooth movement. Aim: The aim of this controlled clinical trial was to compare canine retraction rate and angulation with 0.017”X0.025” versus 0.016”X0.022” stainless steel arch wire with a power arm. Materials and Methods: Twenty-four Class II malocclusion patients (age 13.8± 2.6 years) participated in this study. The teeth were leveled and aligned. Bilateral maxillary first premolars were extracted. In group A, the canines were retracted over 0.017”X0.025” wires. In group B, they were retracted using 0.016”X0.022” wires with a vertical power arm. The retraction force was 150g generated by elastomeric chains. The canine retraction rate and angulation were measured at the end of six months. The rates in the two groups were compared with the t-test and the angulation with the Mann Whitney test. Results: canine retraction rate was 4.64±1.5 in group A and 5.24±1.45 in group B. The canine angulation was 6.41±5.14 and 6.73±6.0 for group A and B, respectively. Conclusion: No difference was observed in the canine retraction rate or angulation with 0.017”X0.025” versus 0.016”X0.022” stainless steel arch wire with a power arm.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
0.017 " X0.025 "的犬齿缩回率和成角对比0.017 " X0.025 "的犬齿缩回率和成角对比0.016 " X0.022 "带动力臂的不锈钢拱丝
背景:拱丝的尺寸影响其刚度和拱丝与支架之间的配合。犬只在较硬的弓丝上收缩,限制了犬只的倾翻程度。然而,电线尺寸越大,抗滑能力越大。众所周知,摩擦阻力会延迟牙齿的运动。目的:本临床对照试验的目的是比较0.017“X0.025”不锈钢弓丝与0.016“X0.022”不锈钢弓丝带动力臂的犬齿内缩率和成角。材料与方法:选取24例II类错颌患者(年龄13.8±2.6岁)。牙齿整齐排列。拔除双侧上颌第一前磨牙。在A组中,犬科动物在0.017“X0.025”的钢丝上收缩。在B组中,使用0.016“X0.022”导线和垂直动力臂进行收缩。弹性体链产生的回缩力为150g。6个月后测量犬的缩回率和成角。用t检验比较两组的发生率,用Mann Whitney检验比较成角率。结果:A组犬齿内缩率为4.64±1.5,B组犬齿内缩率为5.24±1.45,A组犬齿成角率为6.41±5.14,B组犬齿成角率为6.73±6.0。结论:0.017“X0.025”不锈钢弓丝与0.016“X0.022”不锈钢弓丝配合动力臂在犬齿内缩率和成角方面无显著差异。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Measuring Accuracy of Dolphin Imaging Software in predicting upper jaw soft tissue profile changes in Class II Adult Patients treated with Extraction versus Non-Extraction Success of Early Childhood Caries After Treatment with Silver Diamine Fluoride Compared to conventional Glass Ionomer Restoration. A Systematic Review Comparison of Alignment Duration Between 0.018” And 0.022” Slot Brackets in Non-Extraction Orthodontic Adult Patients: A Randomized Clinical Study The Efficiency of Passive Ultrasonic Activated Irrigation on the Retrievability of Guttaflow Bioseal : In Vitro Study Radiographic Analysis of Umbrella Technique Combined with Sticky Bone in Horizontal Ridge Augmentation
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1