{"title":"Detection of Transmission Line Insulator Flashover Based on Categorized Discharge Intensity Level of Ultravoilet Signal","authors":"N. Muhamad, N. A. Rahim, Saiful Mohammad Iezham Suhaimi, N. Bashir, N. A. Ahmad","doi":"10.1109/CMD.2018.8535693","DOIUrl":null,"url":null,"abstract":"Surface discharges are precursors to flashovers. To pre-empt the occurrence of flashover incidents, utility companies need to regularly monitor the condition of line insulators. Recent studies have shown that monitoring of ultra-violet (UV) signals emitted by surface discharges of the insulators is a promising technique. In this study, set of contaminated and aged insulator was used. UV pulse signal of surface discharges activities on these insulators was recorded and analyzed. Experimental result showed that a strong correlation exists between the discharge intensity levels under varying contamination levels and degree of ageing. As the contamination level increased, the discharge levels of the insulator samples intensified, resulting in the increase of total harmonic distortion (THD). THD of the UV signals have been employed by using MATLAB simulation to develop a technique based on artificial neural network (ANN) to classify the flashover prediction based on the discharge intensity levels of the insulator samples. The results of the ANN simulation showed 87% accuracy in the performance index. This study illustrates that UV pulse detection method can be a potential tool to monitor insulator surface conditions during service.","PeriodicalId":6529,"journal":{"name":"2018 Condition Monitoring and Diagnosis (CMD)","volume":"14 1","pages":"1-6"},"PeriodicalIF":0.0000,"publicationDate":"2018-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 Condition Monitoring and Diagnosis (CMD)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CMD.2018.8535693","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Surface discharges are precursors to flashovers. To pre-empt the occurrence of flashover incidents, utility companies need to regularly monitor the condition of line insulators. Recent studies have shown that monitoring of ultra-violet (UV) signals emitted by surface discharges of the insulators is a promising technique. In this study, set of contaminated and aged insulator was used. UV pulse signal of surface discharges activities on these insulators was recorded and analyzed. Experimental result showed that a strong correlation exists between the discharge intensity levels under varying contamination levels and degree of ageing. As the contamination level increased, the discharge levels of the insulator samples intensified, resulting in the increase of total harmonic distortion (THD). THD of the UV signals have been employed by using MATLAB simulation to develop a technique based on artificial neural network (ANN) to classify the flashover prediction based on the discharge intensity levels of the insulator samples. The results of the ANN simulation showed 87% accuracy in the performance index. This study illustrates that UV pulse detection method can be a potential tool to monitor insulator surface conditions during service.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
基于紫外信号放电强度等级分类的输电线路绝缘子闪络检测
表面放电是闪络的前兆。为了预防闪络事故的发生,电力公司需要定期监测线路绝缘子的状况。最近的研究表明,监测绝缘体表面放电发出的紫外线信号是一种很有前途的技术。本研究采用一套污染老化绝缘子。记录并分析了绝缘子表面放电活动的紫外脉冲信号。实验结果表明,不同污染程度下的放电强度与老化程度之间存在较强的相关性。随着污染水平的增加,绝缘子样品的放电水平增强,导致总谐波失真(THD)增加。利用MATLAB仿真,利用紫外信号的THD,开发了一种基于绝缘子放电强度等级的人工神经网络(ANN)分类闪络预测技术。人工神经网络仿真结果表明,性能指标的准确率为87%。该研究表明,紫外脉冲检测方法可以作为一种潜在的工具来监测绝缘子在使用过程中的表面状况。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Author/Paper Index Partial Discharge Analysis on-site in Various High Voltage Apparatus A Novel Anomaly Localization Method on PMU Measure System Based on LS and PCA Effects of Revulcanization on XLPE Crystalline Morphology and AC Breakdown Performance Impact of Voltage Harmonics on Condition Assessment of Polluted Insulator through a Simulation Model
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1