S. Tsukamoto, T. Namihira, D. Wang, S. Katsuki, H. Akiyama, E. Nakashima, A. Sato, Y. Uchida, M. Koike
{"title":"NO/sub x/ and SO/sub 2/ removal by pulsed power at a thermal power plant","authors":"S. Tsukamoto, T. Namihira, D. Wang, S. Katsuki, H. Akiyama, E. Nakashima, A. Sato, Y. Uchida, M. Koike","doi":"10.1109/PPC.1999.823772","DOIUrl":null,"url":null,"abstract":"Recently various methods involving gas discharges and electron beams have been studied for the removal of NO/sub x/ and SO/sub 2/ from flue gases. The recent development of repetitive pulsed power generators gives the pulsed streamer corona discharges a chance of success in the removal of NO/sub x/ and SO/sub 2/. Experiments for the removal of NO/sub x/ and SO/sub 2/ using actual flue gases were performed at a thermal power plant. The results showed that about 90% of NO and about 50% of SO/sub 2/ were removed at a flow rate of 0.8 l/min and a repetition rate of 7 pulses per second (pps). The removal ratio of NO varied inversely proportional to the gas flow rate. The energy efficiency of NO removal was 900 /spl mu/mol/Wh when 50% of NO was removed.","PeriodicalId":11209,"journal":{"name":"Digest of Technical Papers. 12th IEEE International Pulsed Power Conference. (Cat. No.99CH36358)","volume":"1993 1","pages":"1330-1333 vol.2"},"PeriodicalIF":0.0000,"publicationDate":"1999-06-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"7","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Digest of Technical Papers. 12th IEEE International Pulsed Power Conference. (Cat. No.99CH36358)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PPC.1999.823772","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 7
Abstract
Recently various methods involving gas discharges and electron beams have been studied for the removal of NO/sub x/ and SO/sub 2/ from flue gases. The recent development of repetitive pulsed power generators gives the pulsed streamer corona discharges a chance of success in the removal of NO/sub x/ and SO/sub 2/. Experiments for the removal of NO/sub x/ and SO/sub 2/ using actual flue gases were performed at a thermal power plant. The results showed that about 90% of NO and about 50% of SO/sub 2/ were removed at a flow rate of 0.8 l/min and a repetition rate of 7 pulses per second (pps). The removal ratio of NO varied inversely proportional to the gas flow rate. The energy efficiency of NO removal was 900 /spl mu/mol/Wh when 50% of NO was removed.