Reflection spectroscopy on solutions of biological materials in millimeter wave frequency

T. Kurabayashi, K. Konishi, S. Yodokawa, S. Kosaka
{"title":"Reflection spectroscopy on solutions of biological materials in millimeter wave frequency","authors":"T. Kurabayashi, K. Konishi, S. Yodokawa, S. Kosaka","doi":"10.1109/IRMMW-THZ.2015.7327916","DOIUrl":null,"url":null,"abstract":"We attempted to analyze a solution of biological matter of sugars, amino-acids, and electrolytes using a millimeter-wave reflection spectroscopy. The sensitivity for the concentration of solutes was improved markedly, when an adequate dielectric layer was inserted at the interface of incident side of the solution as impedance matched layer. The sensitivity was covered fully in the range of adequate blood sugar level of human as 0.07-0.16 g/100ml H2O in the case of glucose solution.","PeriodicalId":6577,"journal":{"name":"2015 40th International Conference on Infrared, Millimeter, and Terahertz waves (IRMMW-THz)","volume":"8 1","pages":"1-2"},"PeriodicalIF":0.0000,"publicationDate":"2015-11-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 40th International Conference on Infrared, Millimeter, and Terahertz waves (IRMMW-THz)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IRMMW-THZ.2015.7327916","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

Abstract

We attempted to analyze a solution of biological matter of sugars, amino-acids, and electrolytes using a millimeter-wave reflection spectroscopy. The sensitivity for the concentration of solutes was improved markedly, when an adequate dielectric layer was inserted at the interface of incident side of the solution as impedance matched layer. The sensitivity was covered fully in the range of adequate blood sugar level of human as 0.07-0.16 g/100ml H2O in the case of glucose solution.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
毫米波频率下生物材料溶液的反射光谱研究
我们尝试用毫米波反射光谱分析由糖、氨基酸和电解质组成的生物物质溶液。当在溶液入射侧界面处插入适当的介电层作为阻抗匹配层时,对溶质浓度的灵敏度明显提高。对于葡萄糖溶液,其灵敏度完全覆盖在人体适足血糖水平0.07 ~ 0.16 g/100ml H2O范围内。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Measurement and simulation of heat transfer into a human skin phantom THz spectroscopic characterization of biochar Application of T-ray gyrotron developed for real-time non-destructive inspection to enhanced regeneration of cells Output noise temperature of a waveguide cryogenic noise source in W-band Dispersion compensation of the THz communication channels in the atmosphere
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1