The Legend score synthesizes Wells, PERC, Geneva, D-dimer and predicts acute pulmonary embolism prior to imaging tests.

IF 10.4 2区 医学 Q1 RESPIRATORY SYSTEM Pulmonology Pub Date : 2025-12-31 Epub Date: 2024-10-24 DOI:10.1016/j.pulmoe.2023.10.002
Yunfeng Zhao, Yi Cheng, Hongwei Wang, He Du, Jinyuan Sun, Mei Xu, Yong Luo, Song Liu, Xuejun Guo, Wei Xiong
{"title":"The Legend score synthesizes Wells, PERC, Geneva, D-dimer and predicts acute pulmonary embolism prior to imaging tests.","authors":"Yunfeng Zhao, Yi Cheng, Hongwei Wang, He Du, Jinyuan Sun, Mei Xu, Yong Luo, Song Liu, Xuejun Guo, Wei Xiong","doi":"10.1016/j.pulmoe.2023.10.002","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>The prediction rules of acute pulmonary embolism(PE) before imaging tests recommended by the commonly used guidelines have low diagnostic efficiency if not combined with D-dimer, therefore it is necessary to seek for a prediction rule with higher diagnostic efficiency.</p><p><strong>Methods: </strong>We designed a new score named Legend by synthesizing the scores of Wells, PERC, and Geneva, as well as D-dimer with patients in the development group(<i>n</i> = 2112), and then validated it in patients of validation group(<i>n</i> = 388). Diagnostic efficiency was also compared between Legend score and Wells+D-dimer (DD), PERC+DD, Geneva+DD, and YEARS+DD(YEAR algorithm).</p><p><strong>Results: </strong>The Legend score comprised active cancer, D-dimer≥1000 ng/mL, DVT symptoms and/or signs, previous venous thromboembolism (VTE) history, and surgery, trauma, or immobilization in the past month. The sensitivity, specificity, Youden index, and area under the curve(AUC) were 0.985, 0.744, 0.729, and (0.861[0.796-0.925], <i>P</i><0.001), respectively, for original Legend score, whereas were 0.982, 0.778, 0.760, and (0.871[0.823-0.920], <i>P</i><0.001), respectively, for simplified Legend score. The Kappa coefficient and P value of McNemar test were 0.988 and 1.000, respectively, between the original and simplified Legend scores. In the validation group, the sensitivity, specificity, Youden index, and C-index were 0.971, 0.749, 0.720, and (0.838[0.781-0.896], <i>P</i><0.001), respectively, for the original Legend score, whereas were 0.986, 0.715, 0.701, and (0.816[0.750-0.880], <i>P</i> = 0.001) respectively, for the simplified Legend score. The Kappa coefficient and P value of McNemar test between original Legend score and Wells+DD, PERC+DD, Geneva+DD, and YEARS+DD were (0.563, 0.001), (0.139, <0.001), (0.631, 0.006), and (0.732, 0.029), respectively. The Kappa coefficient and P value of McNemar test between simplified Legend score and aforementioned scores were (0.675, 0.009), (0.172, <0.001), (0.747, 0.001), and (0.883, 0.012), respectively.</p><p><strong>Discussion: </strong>In view of the fact the Legend score reserves the efficient predictors and eliminates the inefficient ones in Wells, PERC, and revised Geneva scores, and incorporates D-dimer into it, a more efficient, modified, and user-friendly one has replaced the original ones.</p><p><strong>Conclusions: </strong>The Legend score yields excellent diagnostic efficiency with good safety in the pretest prediction of acute PE prior to imaging tests. It also avoids more unnecessary imaging tests than Wells+DD, PERC+DD, Geneva+DD, or YEARS+DD.</p>","PeriodicalId":54237,"journal":{"name":"Pulmonology","volume":" ","pages":"2416828"},"PeriodicalIF":10.4000,"publicationDate":"2025-12-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Pulmonology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1016/j.pulmoe.2023.10.002","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/10/24 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"RESPIRATORY SYSTEM","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction: The prediction rules of acute pulmonary embolism(PE) before imaging tests recommended by the commonly used guidelines have low diagnostic efficiency if not combined with D-dimer, therefore it is necessary to seek for a prediction rule with higher diagnostic efficiency.

Methods: We designed a new score named Legend by synthesizing the scores of Wells, PERC, and Geneva, as well as D-dimer with patients in the development group(n = 2112), and then validated it in patients of validation group(n = 388). Diagnostic efficiency was also compared between Legend score and Wells+D-dimer (DD), PERC+DD, Geneva+DD, and YEARS+DD(YEAR algorithm).

Results: The Legend score comprised active cancer, D-dimer≥1000 ng/mL, DVT symptoms and/or signs, previous venous thromboembolism (VTE) history, and surgery, trauma, or immobilization in the past month. The sensitivity, specificity, Youden index, and area under the curve(AUC) were 0.985, 0.744, 0.729, and (0.861[0.796-0.925], P<0.001), respectively, for original Legend score, whereas were 0.982, 0.778, 0.760, and (0.871[0.823-0.920], P<0.001), respectively, for simplified Legend score. The Kappa coefficient and P value of McNemar test were 0.988 and 1.000, respectively, between the original and simplified Legend scores. In the validation group, the sensitivity, specificity, Youden index, and C-index were 0.971, 0.749, 0.720, and (0.838[0.781-0.896], P<0.001), respectively, for the original Legend score, whereas were 0.986, 0.715, 0.701, and (0.816[0.750-0.880], P = 0.001) respectively, for the simplified Legend score. The Kappa coefficient and P value of McNemar test between original Legend score and Wells+DD, PERC+DD, Geneva+DD, and YEARS+DD were (0.563, 0.001), (0.139, <0.001), (0.631, 0.006), and (0.732, 0.029), respectively. The Kappa coefficient and P value of McNemar test between simplified Legend score and aforementioned scores were (0.675, 0.009), (0.172, <0.001), (0.747, 0.001), and (0.883, 0.012), respectively.

Discussion: In view of the fact the Legend score reserves the efficient predictors and eliminates the inefficient ones in Wells, PERC, and revised Geneva scores, and incorporates D-dimer into it, a more efficient, modified, and user-friendly one has replaced the original ones.

Conclusions: The Legend score yields excellent diagnostic efficiency with good safety in the pretest prediction of acute PE prior to imaging tests. It also avoids more unnecessary imaging tests than Wells+DD, PERC+DD, Geneva+DD, or YEARS+DD.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Legend评分综合了Wells、PERC、Geneva、d -二聚体,并在影像学检查前预测急性肺栓塞。
导读:常用指南推荐的急性肺栓塞(PE)影像学检查前预测规则如果不结合d -二聚体,诊断效率较低,需要寻求诊断效率更高的预测规则。方法:综合开发组(n = 2112)患者的Wells、PERC、Geneva评分以及d -二聚体评分,设计新的评分Legend,并在验证组(n = 388)患者中进行验证。Legend评分与Wells+ d -二聚体(DD)、PERC+DD、Geneva+DD和YEARS+DD(YEAR算法)的诊断效率也进行了比较。结果:Legend评分包括活动性癌症、d -二聚体≥1000 ng/mL、DVT症状和/或体征、既往静脉血栓栓塞(VTE)史、过去一个月的手术、创伤或固定。灵敏度、特异度、约登指数和曲线下面积(AUC)分别为0.985、0.744、0.729和0.861[0.796-0.925]。讨论:鉴于Legend评分保留了Wells评分、PERC评分和修订后的Geneva评分中有效的预测因子,剔除了无效的预测因子,并将d -二聚体纳入其中,一种更有效、更人性化的改进方法取代了原有的预测因子。结论:Legend评分在影像学检查前预测急性PE方面具有优异的诊断效率和良好的安全性。与Wells+DD、PERC+DD、Geneva+DD或YEARS+DD相比,它还避免了更多不必要的影像学检查。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Pulmonology
Pulmonology Medicine-Pulmonary and Respiratory Medicine
CiteScore
14.30
自引率
5.10%
发文量
159
审稿时长
19 days
期刊介绍: Pulmonology (previously Revista Portuguesa de Pneumologia) is the official journal of the Portuguese Society of Pulmonology (Sociedade Portuguesa de Pneumologia/SPP). The journal publishes 6 issues per year and focuses on respiratory system diseases in adults and clinical research. It accepts various types of articles including peer-reviewed original articles, review articles, editorials, and opinion articles. The journal is published in English and is freely accessible through its website, as well as Medline and other databases. It is indexed in Science Citation Index Expanded, Journal of Citation Reports, Index Medicus/MEDLINE, Scopus, and EMBASE/Excerpta Medica.
期刊最新文献
Effects of hyperoxemia in patients with sepsis - A post-hoc analysis of a multicentre randomized clinical trial. Association of pectoralis muscle area on computed tomography with airflow limitation severity and respiratory outcomes in COPD: A population-based prospective cohort study. Diagnostic yield and safety of transbronchial lung cryobiopsy for diffuse parenchymal lung diseases diagnosis: Comparison between 1.7-mm and 1.9-mm probes. Performance of helmet CPAP using different configurations: Turbine-driven ventilators vs Venturi devices. Alpha-1 antitrypsin deficiency and Pi*S and Pi*Z SERPINA1 variants are associated with asthma exacerbations.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1